BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 2220733)

  • 21. Comparative study of the safety and efficacy of liquid and dry monopolar electrocoagulation in experimental canine bleeding ulcers using computerized energy monitoring.
    Swain CP; Mills TN; Dark JM; Lewin MR; Bown SG; Northfield TC; O'Sullivan JP; Salmon PR
    Gastroenterology; 1984 Jan; 86(1):93-103. PubMed ID: 6605892
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [The bipolar needle electrode in surgical laparoscopy. Initial technical experimental and clinical results].
    Wallwiener D; Rimbach S; Menzer M; Pollmann D; Kaufmann M; Bastert G; Müller W
    Zentralbl Gynakol; 1994; 116(6):325-8. PubMed ID: 8048285
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Detachable snare versus epinephrine injection in the prevention of postpolypectomy bleeding: a randomized and controlled study.
    Di Giorgio P; De Luca L; Calcagno G; Rivellini G; Mandato M; De Luca B
    Endoscopy; 2004 Oct; 36(10):860-3. PubMed ID: 15452780
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Radiofrequency energy-induced heating of bovine capsular tissue: Temperature changes produced by bipolar versus monopolar electrodes.
    Shellock FG
    Arthroscopy; 2001 Feb; 17(2):124-31. PubMed ID: 11172240
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Monopolar electrosurgical thermal management for minimizing tissue damage.
    Dodde RE; Gee JS; Geiger JD; Shih AJ
    IEEE Trans Biomed Eng; 2012 Jan; 59(1):167-73. PubMed ID: 21947515
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Safety technologies for laparoscopic monopolar electrosurgery; devices for managing burn risks.
    ECRI
    Health Devices; 2005 Aug; 34(8):259-72. PubMed ID: 16255230
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Monopolar electrosurgery through single-port laparoscopy: a potential hidden hazard for bowel burns.
    Abu-Rafea B; Vilos GA; Al-Obeed O; AlSheikh A; Vilos AG; Al-Mandeel H
    J Minim Invasive Gynecol; 2011; 18(6):734-40. PubMed ID: 21925969
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Electrosurgical generators and monopolar and bipolar electrosurgery.
    Vilos GA; Rajakumar C
    J Minim Invasive Gynecol; 2013; 20(3):279-87. PubMed ID: 23659748
    [TBL] [Abstract][Full Text] [Related]  

  • 29. [Principals of high frequency surgery].
    Bergler WF; Hörmann K; Hammerschmitt N; Huber K
    Laryngorhinootologie; 2004 Oct; 83(10):683-93; quiz 695-8. PubMed ID: 15476142
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A randomised controlled trial comparing outpatient versus daycase endometrial polypectomy.
    Marsh FA; Rogerson LJ; Duffy SR
    BJOG; 2006 Aug; 113(8):896-901. PubMed ID: 16753049
    [TBL] [Abstract][Full Text] [Related]  

  • 31. A Novel Bipolar Polypectomy Snare Can Be an Alternative Choice for Endoscopic Resection.
    Chen S; Zhou D; Ruan R; Yu J; Li Y; Liu Y; Wang S
    Front Med (Lausanne); 2020; 7():619844. PubMed ID: 33553214
    [No Abstract]   [Full Text] [Related]  

  • 32. Comparison of monopolar and bipolar electrosurgical modes for restorative dentistry: a review of the literature.
    Livaditis GJ
    J Prosthet Dent; 2001 Oct; 86(4):390-9. PubMed ID: 11677534
    [TBL] [Abstract][Full Text] [Related]  

  • 33. The interaction between electrosurgical generators, endoscopic electrodes, and tissue.
    Tucker RD; Sievert CE; Kramolowsky EV; Vennes JA; Silvis SE
    Gastrointest Endosc; 1992; 38(2):118-22. PubMed ID: 1568605
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Characterization and mitigation of stray radiofrequency currents during monopolar resectoscopic electrosurgery.
    Vilos GA; Newton DW; Odell RC; Abu-Rafea B; Vilos AG
    J Minim Invasive Gynecol; 2006; 13(2):134-40. PubMed ID: 16527716
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Hysteroscopic bipolar surgery: a valuable progress or a technique under investigation?
    Garuti G; Luerti M
    Curr Opin Obstet Gynecol; 2009 Aug; 21(4):329-34. PubMed ID: 19512926
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Safety of endoscopic procedures with monopolar versus bipolar instruments in an ex vivo porcine model.
    Shinmura K; Ikematsu H; Kojima M; Nakamura H; Osera S; Yoda Y; Hori K; Oono Y; Ochiai A; Yano T
    BMC Gastroenterol; 2020 Jan; 20(1):27. PubMed ID: 32005163
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Higher currents, greater risks: preventing patient burns at the return-electrode site during high-current electrosurgical procedures.
    ECRI
    Health Devices; 2005 Aug; 34(8):273-9. PubMed ID: 16255231
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Guidance section: ensuring monopolar electrosurgical safety during laparoscopy.
    Health Devices; 1995 Jan; 24(1):20-6. PubMed ID: 7713716
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Diagnostic quality of: polyps resected by snare polypectomy: does the type of electrosurgical current used matter?
    Fry LC; Lazenby AJ; Mikolaenko I; Barranco B; Rickes S; Mönkemüller K
    Am J Gastroenterol; 2006 Sep; 101(9):2123-7. PubMed ID: 16848810
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Endoscopic polypectomy in the upper portion of the digestive system (author's transl)].
    Henke M; Strauch M; Ottenjann R
    Cesk Gastroenterol Vyz; 1974 Jul; 28(5):362-5. PubMed ID: 4845229
    [No Abstract]   [Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.