BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

441 related articles for article (PubMed ID: 22214681)

  • 1. Improving the follow up after EVAR by using ultrasound image fusion of CEUS and MS-CT.
    Clevert DA; Helck A; D'Anastasi M; Gürtler V; Sommer WH; Meimarakis G; Weidenhagen R; Reiser M
    Clin Hemorheol Microcirc; 2011; 49(1-4):91-104. PubMed ID: 22214681
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Single-centre prospective comparison between contrast-enhanced ultrasound and computed tomography angiography after EVAR.
    Perini P; Sediri I; Midulla M; Delsart P; Mouton S; Gautier C; Pruvo JP; Haulon S
    Eur J Vasc Endovasc Surg; 2011 Dec; 42(6):797-802. PubMed ID: 21962588
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A comparison between contrast-enhanced ultrasound imaging and multislice computed tomography in detecting and classifying endoleaks in the follow-up after endovascular aneurysm repair.
    Gürtler VM; Sommer WH; Meimarakis G; Kopp R; Weidenhagen R; Reiser MF; Clevert DA
    J Vasc Surg; 2013 Aug; 58(2):340-5. PubMed ID: 23591188
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Contrast-enhanced ultrasound versus color duplex ultrasound imaging in the follow-up of patients after endovascular abdominal aortic aneurysm repair.
    Iezzi R; Basilico R; Giancristofaro D; Pascali D; Cotroneo AR; Storto ML
    J Vasc Surg; 2009 Mar; 49(3):552-60. PubMed ID: 19135839
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Contrast-enhanced ultrasound versus computed tomographic angiography for surveillance of endovascular abdominal aortic aneurysm repair.
    Ten Bosch JA; Rouwet EV; Peters CT; Jansen L; Verhagen HJ; Prins MH; Teijink JA
    J Vasc Interv Radiol; 2010 May; 21(5):638-43. PubMed ID: 20363153
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Detection and characterization of endoleaks following endovascular treatment of abdominal aortic aneurysms using contrast harmonic imaging (CHI) with quantitative perfusion analysis (TIC) compared to CT angiography (CTA).
    Jung EM; Rennert J; Fellner C; Uller W; Jung W; Schreyer A; Heiss P; Hoffstetter P; Feuerbach S; Kasparzk P; Zorger N; Pfister K
    Ultraschall Med; 2010 Dec; 31(6):564-70. PubMed ID: 19941253
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Contrast-enhanced ultrasound vs. CT angiography in fenestrated EVAR surveillance: a single-center comparison.
    Perini P; Sediri I; Midulla M; Delsart P; Gautier C; Haulon S
    J Endovasc Ther; 2012 Oct; 19(5):648-55. PubMed ID: 23046331
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Color duplex ultrasound and contrast-enhanced ultrasound in comparison to MS-CT in the detection of endoleak following endovascular aneurysm repair.
    Clevert DA; Minaifar N; Weckbach S; Kopp R; Meimarakis G; Clevert DA; Reiser M
    Clin Hemorheol Microcirc; 2008; 39(1-4):121-32. PubMed ID: 18503118
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Use of three-dimensional contrast-enhanced duplex ultrasound imaging during endovascular aneurysm repair.
    Ormesher DC; Lowe C; Sedgwick N; McCollum CN; Ghosh J
    J Vasc Surg; 2014 Dec; 60(6):1468-72. PubMed ID: 25282700
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Contrast-enhanced ultrasonography versus computed tomographic angiography in the monitoring of patients after endovascular repair of abdominal aortic aneurysm -- preliminary experience.
    Ustymowicz A; Janica J; Kowalewski R; Lewszuk A; Lukasiewicz A; michalak P; Waszczeniuk-Sobotko O
    Nucl Med Rev Cent East Eur; 2009; 12(2):95-8. PubMed ID: 20235062
    [TBL] [Abstract][Full Text] [Related]  

  • 11. First experience using intraoperative contrast-enhanced ultrasound during endovascular aneurysm repair for infrarenal aortic aneurysms.
    Kopp R; Zürn W; Weidenhagen R; Meimarakis G; Clevert DA
    J Vasc Surg; 2010 May; 51(5):1103-10. PubMed ID: 20420978
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Contrast Enhanced Ultrasound can Replace Computed Tomography Angiography for Surveillance After Endovascular Aortic Aneurysm Repair.
    Bredahl KK; Taudorf M; Lönn L; Vogt KC; Sillesen H; Eiberg JP
    Eur J Vasc Endovasc Surg; 2016 Dec; 52(6):729-734. PubMed ID: 27760698
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Standardized 2D ultrasound versus 3D/4D ultrasound and image fusion for measurement of aortic aneurysm diameter in follow-up after EVAR.
    Pfister K; Schierling W; Jung EM; Apfelbeck H; Hennersperger C; Kasprzak PM
    Clin Hemorheol Microcirc; 2016; 62(3):249-60. PubMed ID: 26484714
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Contrast harmonic imaging ultrasound and perfusion imaging for surveillance after endovascular abdominal aneurysm repair regarding detection and characterization of suspected endoleaks.
    Pfister K; Rennert J; Uller W; Schnitzbauer AA; Stehr A; Jung W; Hofstetter P; Zorger N; Kasprzak PM; Jung EM
    Clin Hemorheol Microcirc; 2009; 43(1-2):119-28. PubMed ID: 19713606
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Prospective comparative analysis of colour-Doppler ultrasound, contrast-enhanced ultrasound, computed tomography and magnetic resonance in detecting endoleak after endovascular abdominal aortic aneurysm repair.
    Cantisani V; Ricci P; Grazhdani H; Napoli A; Fanelli F; Catalano C; Galati G; D'Andrea V; Biancari F; Passariello R
    Eur J Vasc Endovasc Surg; 2011 Feb; 41(2):186-92. PubMed ID: 21095141
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Image fusion of contrast enhanced ultrasound (CEUS) with computed tomography (CT) or magnetic resonance imaging (MRI) using volume navigation for detection, characterization and planning of therapeutic interventions of liver tumors.
    Rennert J; Georgieva M; Schreyer AG; Jung W; Ross C; Stroszczynski C; Jung EM
    Clin Hemorheol Microcirc; 2011; 49(1-4):67-81. PubMed ID: 22214679
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Could four-dimensional contrast-enhanced ultrasound replace computed tomography angiography during follow up of fenestrated endografts? Results of a preliminary experience.
    Gargiulo M; Gallitto E; Serra C; Freyrie A; Mascoli C; Bianchini Massoni C; De Matteis M; De Molo C; Stella A
    Eur J Vasc Endovasc Surg; 2014 Nov; 48(5):536-42. PubMed ID: 25023904
    [TBL] [Abstract][Full Text] [Related]  

  • 18. 3D contrast enhanced ultrasound for detecting endoleak following endovascular aneurysm repair (EVAR).
    Abbas A; Hansrani V; Sedgwick N; Ghosh J; McCollum CN
    Eur J Vasc Endovasc Surg; 2014 May; 47(5):487-92. PubMed ID: 24618331
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Contrast-enhanced ultrasound detects type II endoleaks during follow-up for endovascular aneurysm repair.
    Johnsen L; Hisdal J; Jonung T; Braaten A; Pedersen G
    J Vasc Surg; 2020 Dec; 72(6):1952-1959. PubMed ID: 32249048
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Intra-operative cone beam computed tomography can help avoid reinterventions and reduce CT follow up after infrarenal EVAR.
    Törnqvist P; Dias N; Sonesson B; Kristmundsson T; Resch T
    Eur J Vasc Endovasc Surg; 2015 Apr; 49(4):390-5. PubMed ID: 25736514
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 23.