These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
26. The use of experimental design in the development of an HPLC-ECD method for the analysis of captopril. Khamanga SM; Walker RB Talanta; 2011 Jan; 83(3):1037-49. PubMed ID: 21147355 [TBL] [Abstract][Full Text] [Related]
27. Development and application of a specially designed heating system for temperature-programmed high-performance liquid chromatography using subcritical water as the mobile phase. Teutenberg T; Goetze HJ; Tuerk J; Ploeger J; Kiffmeyer TK; Schmidt KG; Kohorst Wg; Rohe T; Jansen HD; Weber H J Chromatogr A; 2006 May; 1114(1):89-96. PubMed ID: 16530210 [TBL] [Abstract][Full Text] [Related]
28. Simultaneous determination of some food additives in soft drinks and other liquid foods by flow injection on-line dialysis coupled to high performance liquid chromatography. Kritsunankul O; Jakmunee J Talanta; 2011 Jun; 84(5):1342-9. PubMed ID: 21641449 [TBL] [Abstract][Full Text] [Related]
29. A practical approach for predicting retention time shifts due to pressure and temperature gradients in ultra-high-pressure liquid chromatography. Åsberg D; Chutkowski M; Leśko M; Samuelsson J; Kaczmarski K; Fornstedt T J Chromatogr A; 2017 Jan; 1479():107-120. PubMed ID: 27986288 [TBL] [Abstract][Full Text] [Related]
30. Development of a high performance liquid chromatography method and a liquid chromatography-tandem mass spectrometry method with the pressurized liquid extraction for the quantification and confirmation of sulfonamides in the foods of animal origin. Yu H; Tao Y; Chen D; Wang Y; Huang L; Peng D; Dai M; Liu Z; Wang X; Yuan Z J Chromatogr B Analyt Technol Biomed Life Sci; 2011 Sep; 879(25):2653-62. PubMed ID: 21840270 [TBL] [Abstract][Full Text] [Related]
31. Rapid high performance liquid chromatography method development with high prediction accuracy, using 5cm long narrow bore columns packed with sub-2microm particles and Design Space computer modeling. Fekete S; Fekete J; Molnár I; Ganzler K J Chromatogr A; 2009 Nov; 1216(45):7816-23. PubMed ID: 19815221 [TBL] [Abstract][Full Text] [Related]
32. Multilinear gradient elution optimization in reversed-phase liquid chromatography based on logarithmic retention models: application to separation of a set of purines, pyrimidines and nucleosides. Nikitas P; Pappa-Louisi A; Agrafiotou P; Mansour A J Chromatogr A; 2011 Aug; 1218(33):5658-63. PubMed ID: 21774937 [TBL] [Abstract][Full Text] [Related]
33. Analysis of hydrophilic metabolites by high-performance liquid chromatography-mass spectrometry using a silica hydride-based stationary phase. Pesek JJ; Matyska MT; Fischer SM; Sana TR J Chromatogr A; 2008 Sep; 1204(1):48-55. PubMed ID: 18701108 [TBL] [Abstract][Full Text] [Related]
34. The ultimate band compression factor in gradient elution chromatography. Gritti F; Guiochon G J Chromatogr A; 2008 Jan; 1178(1-2):79-91. PubMed ID: 18062981 [TBL] [Abstract][Full Text] [Related]
35. Combined effects of mobile phase composition and temperature on the retention of homologous and polar test compounds on polydentate C8 column. Jandera P; Krupczyńska K; Vynuchalová K; Buszewski B J Chromatogr A; 2010 Sep; 1217(39):6052-60. PubMed ID: 20728897 [TBL] [Abstract][Full Text] [Related]
36. Numerical modeling of elution peak profiles in supercritical fluid chromatography. Part I--elution of an unretained tracer. Kaczmarski K; Poe DP; Guiochon G J Chromatogr A; 2010 Oct; 1217(42):6578-87. PubMed ID: 20813372 [TBL] [Abstract][Full Text] [Related]
37. Modeling the effects of different mobile phase compositions and temperatures on the retention of various analytes in HPLC. Jouyban A; Soltanpour S; Acree WE; Thomas D; Agrafiotou P; Pappa-Louisi A J Sep Sci; 2009 Nov; 32(22):3898-905. PubMed ID: 19842120 [TBL] [Abstract][Full Text] [Related]
38. Modelling of retention of pesticides in reversed-phase high-performance liquid chromatography: quantitative structure-retention relationships based on solute quantum-chemical descriptors and experimental (solvatochromic and spin-probe) mobile phase descriptors. D'Archivio AA; Ruggieri F; Mazzeo P; Tettamanti E Anal Chim Acta; 2007 Jun; 593(2):140-51. PubMed ID: 17543600 [TBL] [Abstract][Full Text] [Related]
39. Influence of frictional heating on temperature gradients in ultra-high-pressure liquid chromatography on 2.1mm I.D. columns. de Villiers A; Lauer H; Szucs R; Goodall S; Sandra P J Chromatogr A; 2006 Apr; 1113(1-2):84-91. PubMed ID: 16476437 [TBL] [Abstract][Full Text] [Related]
40. Simultaneous analysis of aspartame and its hydrolysis products of Coca-Cola Zero by on-line postcolumn derivation fluorescence detection and ultraviolet detection coupled two-dimensional high-performance liquid chromatography. Cheng C; Wu SC J Chromatogr A; 2011 May; 1218(20):2976-83. PubMed ID: 21481403 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]