  • 1. Relationship between Sprint Fidelis leads and patient mortality.
    Maytin M; Epstein LM
    J Am Coll Cardiol; 2012 Jan; 59(2):193-4. PubMed ID: 22222084
    [No Abstract]   [Full Text] [Related]  

  • 2. Mortality risk of Fidelis management.
    Faddis MN
    J Am Coll Cardiol; 2011 Jul; 58(3):284-5. PubMed ID: 21737020
    [No Abstract]   [Full Text] [Related]  

  • 3. Impact of implanted recalled sprint Fidelis lead on patient mortality.
    Morrison TB; Friedman PA; Kallinen LM; Hodge DO; Crusan D; Kumar K; Hayes DL; Rea RF; Hauser RG
    J Am Coll Cardiol; 2011 Jul; 58(3):278-83. PubMed ID: 21737019
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Sudden and Fatal Malfunction of a Durata Defibrillator Lead due to External Insulation Failure.
    Shah AD; Hirsh DS; Langberg JJ
    Pacing Clin Electrophysiol; 2016 Jan; 39(1):101-4. PubMed ID: 26293817
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A fatal complication of ICD therapy due to lead failure.
    Theuns DA; Szili-Torok T; Jordaens LJ
    J Cardiovasc Electrophysiol; 2008 Jul; 19(7):E48. PubMed ID: 18554196
    [No Abstract]   [Full Text] [Related]  

  • 6. The Sprint Fidelis lead fracture story: what do we really know and where do we go from here?
    Ellenbogen KA; Wood MA; Swerdlow CD
    Heart Rhythm; 2008 Oct; 5(10):1380-1. PubMed ID: 18929322
    [No Abstract]   [Full Text] [Related]  

  • 7. Inappropriate implantable cardioverter defibrillator shocks in fractured Sprint Fidelis leads associated with 'appropriate' interrogation.
    Farwell D; Redpath C; Birnie D; Gollob M; Lemery R; Posan E; Green M
    Europace; 2008 Jun; 10(6):726-8. PubMed ID: 18456645
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Failure of implantable cardioverter-defibrillator leads: a matter of lead size?
    Rordorf R; Poggio L; Savastano S; Vicentini A; Petracci B; Chieffo E; Klersy C; Landolina M
    Heart Rhythm; 2013 Feb; 10(2):184-90. PubMed ID: 23063430
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Transvenous implantable cardioverter-defibrillator leads: the weakest link.
    Maisel WH
    Circulation; 2007 May; 115(19):2461-3. PubMed ID: 17502585
    [No Abstract]   [Full Text] [Related]  

  • 10. Lead integrity alert algorithm decreases inappropriate shocks in patients who have Sprint Fidelis pace-sense conductor fractures.
    Kallinen LM; Hauser RG; Tang C; Melby DP; Almquist AK; Katsiyiannis WT; Gornick CC
    Heart Rhythm; 2010 Aug; 7(8):1048-55. PubMed ID: 20493965
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Clinical outcomes in patients with implantable cardioverter defibrillators and Sprint Fidelis leads.
    Verlato R; Facchin D; Catanzariti D; Molon G; Zanotto G; Morani G; Brieda M; Zanon F; Delise P; Leoni L; Comisso J; Campo C
    Heart; 2013 Jun; 99(11):799-804. PubMed ID: 23434626
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Lead electrical parameters may not predict integrity of the Sprint Fidelis ICD lead.
    Maytin M; Epstein LM
    Heart Rhythm; 2012 Sep; 9(9):1446-51. PubMed ID: 22537883
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of Sprint Fidelis and Riata defibrillator lead failure rates.
    Fazal IA; Shepherd EJ; Tynan M; Plummer CJ; McComb JM
    Int J Cardiol; 2013 Sep; 168(2):848-52. PubMed ID: 23138013
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accelerating risk of Fidelis lead fracture.
    Farwell D; Green MS; Lemery R; Gollob MH; Birnie DH
    Heart Rhythm; 2008 Oct; 5(10):1375-9. PubMed ID: 18783996
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Computed tomography's crucial role in averting a life-threatening complication of lead extraction.
    Srivatsa UN; Dinh H; Stark S
    Heart Rhythm; 2013 Feb; 10(2):308-9. PubMed ID: 21952005
    [No Abstract]   [Full Text] [Related]  

  • 16. Failure of impedance monitoring to prevent adverse clinical events caused by fracture of a recalled high-voltage implantable cardioverter-defibrillator lead.
    Kallinen LM; Hauser RG; Lee KW; Almquist AK; Katsiyiannis WT; Tang CY; Melby DP; Gornick CC
    Heart Rhythm; 2008 Jun; 5(6):775-9. PubMed ID: 18534361
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Increasing hazard of Sprint Fidelis implantable cardioverter-defibrillator lead failure.
    Hauser RG; Hayes DL
    Heart Rhythm; 2009 May; 6(5):605-10. PubMed ID: 19285920
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Update on small-diameter implantable cardioverter-defibrillator leads performance.
    van Rees JB; van Welsenes GH; Borleffs CJ; Thijssen J; van der Velde ET; van der Wall EE; van Erven L; Schalij MJ
    Pacing Clin Electrophysiol; 2012 Jun; 35(6):652-8. PubMed ID: 22352338
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Unusual failure of a multilumen, small-diameter implantable cardioverter-defibrillator lead.
    Jalal Z; Derval N; Ploux S; Bordachar P
    Heart Rhythm; 2010 Aug; 7(8):1166-7. PubMed ID: 20149982
    [No Abstract]   [Full Text] [Related]  

  • 20. Complications associated with revision of Sprint Fidelis leads: report from the Canadian Heart Rhythm Society Device Advisory Committee.
    Parkash R; Crystal E; Bashir J; Simpson C; Birnie D; Sterns L; Exner D; Thibault B; Connors S; Healey JS; Champagne J; Cameron D; Mangat I; Verma A; Wolfe K; Essebag V; Kus T; Ayala-Paredes F; Davies T; Sanatani S; Gow R; Coutu B; Sivakumaran S; Stephenson E; Krahn A
    Circulation; 2010 Jun; 121(22):2384-7. PubMed ID: 20497979
    [TBL] [Abstract][Full Text] [Related]  