These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

107 related articles for article (PubMed ID: 2222715)

  • 1. [Equipment for respiratory gas conditioning under hygienic conditions].
    Soltau U; Bonell R; Kaufhold W; Baumann B
    Anaesthesiol Reanim; 1990; 15(4):205-11. PubMed ID: 2222715
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Prevention of exogenous respiratory infection].
    Goetz ML; Pottecher B; Eberhart R; Vautravers MJ; Pottecher T
    Agressologie; 1990; 31(8 Spec No):483-8. PubMed ID: 2089967
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Review of the development of air humidifiers working on the principle of evaporation with reference to their experimentally assured efficacy].
    Viehberg H; Tontschev G; Bensow C
    Z Exp Chir; 1979 Aug; 12(4):258-68. PubMed ID: 394493
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A comparison of the rate of bacterial contamination for prefilled disposable and reusable oxygen humidifiers.
    Yamashita K; Nishiyama T; Yokoyama T; Abe H; Manabe M
    J Crit Care; 2005 Jun; 20(2):172-5; discussion 175. PubMed ID: 16139158
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Bacterial contamination potential of sterile, prefilled humidifiers and nebulizer reservoirs.
    Koss JA; Conine TA; Eitzen HE; LoSasso AM
    Heart Lung; 1979; 8(6):1117-21. PubMed ID: 259068
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [New potentials for monitoring the temperature and the relative and absolute humidity of the air-oxygen mixture during the prolonged artificial ventilation of newborn infants].
    Milenin OB; Efimov MS
    Anesteziol Reanimatol; 1998; (1):49-52. PubMed ID: 9553263
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The effects of passive humidifier dead space on respiratory variables in paralyzed and spontaneously breathing patients.
    Campbell RS; Davis K; Johannigman JA; Branson RD
    Respir Care; 2000 Mar; 45(3):306-12. PubMed ID: 10771799
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The effects of excessive humidity.
    Williams RB
    Respir Care Clin N Am; 1998 Jun; 4(2):215-28. PubMed ID: 9648183
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Characteristics of several humidifiers for CPAP-therapy, invasive and non-invasive ventilation and oxygen therapy under standardised climatic conditions in a climatic chamber].
    Wenzel M; Wenzel G; Klauke M; Kerl J; Hund-Rinke K
    Pneumologie; 2008 Jun; 62(6):324-9. PubMed ID: 18535976
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Devices used to humidify respired gases.
    Rathgeber J
    Respir Care Clin N Am; 2006 Jun; 12(2):165-82. PubMed ID: 16828689
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Use of Normothermic Default Humidifier Settings Causes Excessive Humidification of Respiratory Gases During Therapeutic Hypothermia.
    Tanaka S; Iwata S; Kinoshita M; Tsuda K; Sakai S; Saikusa M; Shindo R; Harada E; Okada J; Hisano T; Kanda H; Maeno Y; Araki Y; Ushijima K; Sakamoto T; Yamashita Y; Iwata O
    Ther Hypothermia Temp Manag; 2016 Dec; 6(4):180-188. PubMed ID: 27167667
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effect of humidification on the incidence of ventilator-associated pneumonia.
    Ricard JD; Boyer A; Dreyfuss D
    Respir Care Clin N Am; 2006 Jun; 12(2):263-73. PubMed ID: 16828694
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Humidification of respired gases in neonates and infants.
    Schiffmann H
    Respir Care Clin N Am; 2006 Jun; 12(2):321-36. PubMed ID: 16828698
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Preservation of humidity and heat of respiratory gases in patients with a minute ventilation greater than 10 L/min.
    Martin C; Papazian L; Perrin G; Saux P; Gouin F
    Crit Care Med; 1994 Nov; 22(11):1871-6. PubMed ID: 7956294
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The efficiency of various humidifiers for respired gas.
    Tontschev G; Lueder M; Bensow C
    Resuscitation; 1980 Sep; 8(3):167-79. PubMed ID: 7444216
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [On the problem of optimal warming and moistening of the inspired gases in controlled and assisted artificial ventilation (author's transl)].
    Lang VO
    Anaesthesist; 1979 Mar; 28(3):125-35. PubMed ID: 434427
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Extended use of prefilled humidifier reservoirs and the likelihood of contamination.
    Seigel D; Romo B
    Respir Care; 1990 Aug; 35(8):806. PubMed ID: 10145318
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Performance of heated wire humidifiers: an in vitro study.
    Pelosi P; Chiumello D; Severgnini P; De Grandis CE; Landi L; Chierichetti LM; Frigerio A; Munaro M; Park G; Chiaranda M
    J Crit Care; 2007 Sep; 22(3):258-64. PubMed ID: 17869979
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Filters reduce the risk of bacterial transmission from contaminated heated humidifiers used with CPAP for obstructive sleep apnea.
    Ortolano GA; Schaffer J; McAlister MB; Stanchfield I; Hill E; Vandenburgh L; Lewis M; John S; Canonica FP; Cervia JS
    J Clin Sleep Med; 2007 Dec; 3(7):700-5. PubMed ID: 18198803
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An in-hospital evaluation of the sonic mist ultrasonic room humidifier.
    Chatburn RL; Lough MD; Klinger JD
    Respir Care; 1984 Sep; 29(9):893-9. PubMed ID: 10315606
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.