BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

191 related articles for article (PubMed ID: 22228288)

  • 1. Is a fully heparin-bonded cardiopulmonary bypass circuit superior to a standard cardiopulmonary bypass circuit?
    Mahmood S; Bilal H; Zaman M; Tang A
    Interact Cardiovasc Thorac Surg; 2012 Apr; 14(4):406-14. PubMed ID: 22228288
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biocompatibility of heparin-coated extracorporeal bypass circuits: a randomized, masked clinical trial.
    Muehrcke DD; McCarthy PM; Kottke-Marchant K; Harasaki H; Pierre-Yared J; Borsh JA; Ogella DA; Cosgrove DM
    J Thorac Cardiovasc Surg; 1996 Aug; 112(2):472-83. PubMed ID: 8751516
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Closed, phosphorylcholine-coated circuit and reduction of systemic heparinization for cardiopulmonary bypass: the intraoperative ECMO concept.
    Ranucci M; Pazzaglia A; Isgrò G; Cazzaniga A; Ditta A; Boncilli A; Cotza M; Carboni G; Brozzi S; Bonifazi C
    Int J Artif Organs; 2002 Sep; 25(9):875-81. PubMed ID: 12403404
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Limitation of thrombin generation, platelet activation, and inflammation by elimination of cardiotomy suction in patients undergoing coronary artery bypass grafting treated with heparin-bonded circuits.
    Aldea GS; Soltow LO; Chandler WL; Triggs CM; Vocelka CR; Crockett GI; Shin YT; Curtis WE; Verrier ED
    J Thorac Cardiovasc Surg; 2002 Apr; 123(4):742-55. PubMed ID: 11986603
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Deleterious effects of cardiopulmonary bypass on early graft function after single lung allotransplantation: evaluation of a heparin-coated bypass circuit.
    Francalancia NA; Aeba R; Yousem SA; Griffith BP; Marrone GC
    J Heart Lung Transplant; 1994; 13(3):498-507. PubMed ID: 8061027
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Superior biocompatibility of heparin-bonded circuits in pediatric cardiopulmonary bypass.
    Ozawa T; Yoshihara K; Koyama N; Yamazaki S; Takanashi Y
    Jpn J Thorac Cardiovasc Surg; 1999 Dec; 47(12):592-9. PubMed ID: 10658376
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Can a mini-bypass circuit improve perfusion in cardiac surgery compared to conventional cardiopulmonary bypass?
    Alevizou A; Dunning J; Park JD
    Interact Cardiovasc Thorac Surg; 2009 Apr; 8(4):457-66. PubMed ID: 19153170
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cell activation and thrombin generation in heparin bonded cardiopulmonary bypass circuits using a novel in vitro model.
    Bannan S; Danby A; Cowan D; Ashraf S; Gesinde M; Martin P
    Eur J Cardiothorac Surg; 1997 Aug; 12(2):268-75. PubMed ID: 9288518
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of anticoagulation protocol on outcome in patients undergoing CABG with heparin-bonded cardiopulmonary bypass circuits.
    Aldea GS; O'Gara P; Shapira OM; Treanor P; Osman A; Patalis E; Arkin C; Diamond R; Babikian V; Lazar HL; Shemin RJ
    Ann Thorac Surg; 1998 Feb; 65(2):425-33. PubMed ID: 9485240
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Enhanced blood conservation and improved clinical outcome after valve surgery using heparin-bonded cardiopulmonary bypass circuits.
    Shapira OM; Aldea GS; Zelingher J; Volpe C; Fitzgerald C; DeAndrade K; Lazar HL; Shemin RJ
    J Card Surg; 1996; 11(5):307-17. PubMed ID: 8969375
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Clinical and biomaterial evaluation of hyaluronan-based heparin-bonded extracorporeal circuits with reduced versus full systemic anticoagulation in reoperation for coronary revascularization.
    Gunaydin S; Farsak B; McCusker K; Vijay V; Sari T; Onur MA; Gurpinar A; Zorlutuna Y
    J Cardiovasc Med (Hagerstown); 2009 Feb; 10(2):135-42. PubMed ID: 19377380
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Heparin-coated cardiopulmonary bypass circuit: clinical effects in pediatric cardiac surgery.
    Miyaji K; Hannan RL; Ojito J; Jacobs JP; White JA; Burke RP
    J Card Surg; 2000; 15(3):194-8. PubMed ID: 11414605
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Heparin-bonded circuits: clinical outcomes and costs.
    Mahoney CB
    Perfusion; 1998 May; 13(3):192-204. PubMed ID: 9638717
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Heparin-coated circuits reduce complement activation and inflammatory response to cardiopulmonary bypass.
    Tamim M; Demircin M; Guvener M; Peker O; Yilmaz M
    Panminerva Med; 1999 Sep; 41(3):193-8. PubMed ID: 10568115
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Management of Heparin-Resistant Patients with Benefits? Maximizing Biocompatibility in Cardiopulmonary Bypass: Combining ATryn® Recombinant Antithrombin III and Carmeda® Heparin-Bonded Perfusion Circuits: A Case Series.
    Chryssos A; Stroup SJ; Pifer MM; Tawil M; Conrad CG
    J Extra Corpor Technol; 2015 Mar; 47(1):44-7. PubMed ID: 26390679
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cardiopulmonary bypass with heparin-coated circuits and reduced systemic anticoagulation.
    Kuitunen AH; Heikkilä LJ; Salmenperä MT
    Ann Thorac Surg; 1997 Feb; 63(2):438-44. PubMed ID: 9033316
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Surface-bound heparin fails to reduce thrombin formation during clinical cardiopulmonary bypass.
    Gorman RC; Ziats N; Rao AK; Gikakis N; Sun L; Khan MM; Stenach N; Sapatnekar S; Chouhan V; Gorman JH; Niewiarowski S; Colman RW; Anderson JM; Edmunds LH
    J Thorac Cardiovasc Surg; 1996 Jan; 111(1):1-11; discussion 11-2. PubMed ID: 8551753
    [TBL] [Abstract][Full Text] [Related]  

  • 18. No benefit of reduced heparinization in thoracic aortic operation with heparin-coated bypass circuits.
    Olsson C; Siegbahn A; Haldén E; Nilsson B; Venge P; Thelin S
    Ann Thorac Surg; 2000 Mar; 69(3):743-9. PubMed ID: 10750754
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A randomized study of coronary artery bypass surgery performed with the Resting Heart™ System utilizing a low vs a standard dosage of heparin.
    Nilsson J; Scicluna S; Malmkvist G; Pierre L; Algotsson L; Paulsson P; Bjursten H; Johnsson P
    Interact Cardiovasc Thorac Surg; 2012 Nov; 15(5):834-9. PubMed ID: 22914806
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Heparin-bonded circuits with a reduced anticoagulation protocol in primary CABG: a prospective, randomized study.
    Aldea GS; Doursounian M; O'Gara P; Treanor P; Shapira OM; Lazar HL; Shemin RJ
    Ann Thorac Surg; 1996 Aug; 62(2):410-7; discussion 417-8. PubMed ID: 8694599
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.