166 related articles for article (PubMed ID: 22245751)
1. Analysis of post-exposure density growth in radiochromic film with respect to the radiation dose.
Shima K; Tateoka K; Saitoh Y; Suzuki J; Yaegashi Y; Fujimoto K; Nakazawa T; Nakata A; Abe T; Imai S; Sakata K; Hareyama M
J Radiat Res; 2012; 53(2):301-5. PubMed ID: 22245751
[TBL] [Abstract][Full Text] [Related]
2. Dosimetric characterization of GafChromic EBT film and its implication on film dosimetry quality assurance.
Fuss M; Sturtewagen E; De Wagter C; Georg D
Phys Med Biol; 2007 Jul; 52(14):4211-25. PubMed ID: 17664604
[TBL] [Abstract][Full Text] [Related]
3. Evaluation of an Epson flatbed scanner to read Gafchromic EBT films for radiation dosimetry.
Ferreira BC; Lopes MC; Capela M
Phys Med Biol; 2009 Feb; 54(4):1073-85. PubMed ID: 19168937
[TBL] [Abstract][Full Text] [Related]
4. Post-irradiation colouration of Gafchromic EBT radiochromic film.
Cheung T; Butson MJ; Yu PK
Phys Med Biol; 2005 Oct; 50(20):N281-5. PubMed ID: 16204869
[TBL] [Abstract][Full Text] [Related]
5. Precautions and strategies in using a commercial flatbed scanner for radiochromic film dosimetry.
Paelinck L; De Neve W; De Wagter C
Phys Med Biol; 2007 Jan; 52(1):231-42. PubMed ID: 17183138
[TBL] [Abstract][Full Text] [Related]
6. A prototype, glassless densitometer traceable to primary optical standards for quantitative radiochromic film dosimetry.
Rosen BS; Soares CG; Hammer CG; Kunugi KA; DeWerd LA
Med Phys; 2015 Jul; 42(7):4055-68. PubMed ID: 26133606
[TBL] [Abstract][Full Text] [Related]
7. Dose-response curve of EBT, EBT2, and EBT3 radiochromic films to synchrotron-produced monochromatic x-ray beams.
Brown TA; Hogstrom KR; Alvarez D; Matthews KL; Ham K; Dugas JP
Med Phys; 2012 Dec; 39(12):7412-7. PubMed ID: 23231291
[TBL] [Abstract][Full Text] [Related]
8. Important considerations for radiochromic film dosimetry with flatbed CCD scanners and EBT GAFCHROMIC film.
Lynch BD; Kozelka J; Ranade MK; Li JG; Simon WE; Dempsey JF
Med Phys; 2006 Dec; 33(12):4551-6. PubMed ID: 17278806
[TBL] [Abstract][Full Text] [Related]
9. GafChromic EBT film dosimetry with flatbed CCD scanner: a novel background correction method and full dose uncertainty analysis.
Saur S; Frengen J
Med Phys; 2008 Jul; 35(7):3094-101. PubMed ID: 18697534
[TBL] [Abstract][Full Text] [Related]
10. Comparison of the epson expression 1680 flatbed and the vidar VXR-16 dosimetry PRO film scanners for use in IMRT dosimetry using gafchromic and radiographic film.
Wilcox E; Daskalov G; Nedialkova L
Med Phys; 2007 Jan; 34(1):41-8. PubMed ID: 17278488
[TBL] [Abstract][Full Text] [Related]
11. Multichannel film dosimetry with nonuniformity correction.
Micke A; Lewis DF; Yu X
Med Phys; 2011 May; 38(5):2523-34. PubMed ID: 21776787
[TBL] [Abstract][Full Text] [Related]
12. Scanning orientation effects on Gafchromic EBT film dosimetry.
Butson MJ; Cheung T; Yu PK
Australas Phys Eng Sci Med; 2006 Sep; 29(3):281-4. PubMed ID: 17058592
[TBL] [Abstract][Full Text] [Related]
13. A prototype quantitative film scanner for radiochromic film dosimetry.
Ranade MK; Li JG; Dubose RS; Kozelka J; Simon WE; Dempsey JF
Med Phys; 2008 Feb; 35(2):473-9. PubMed ID: 18383667
[TBL] [Abstract][Full Text] [Related]
14. High-precision GAFCHROMIC EBT film-based absolute clinical dosimetry using a standard flatbed scanner without the use of a scanner non-uniformity correction.
Chung H; Lynch B; Samant S
J Appl Clin Med Phys; 2010 Apr; 11(2):3112. PubMed ID: 20592696
[TBL] [Abstract][Full Text] [Related]
15. Evaluation of a commercial flatbed document scanner and radiographic film scanner for radiochromic EBT film dosimetry.
Matney JE; Parker BC; Neck DW; Henkelmann G; Rosen II
J Appl Clin Med Phys; 2010 Apr; 11(2):3165. PubMed ID: 20592699
[TBL] [Abstract][Full Text] [Related]
16. Investigation of energy dependence of EBT and EBT-2 gafchromic film.
Lindsay P; Rink A; Ruschin M; Jaffray D
Med Phys; 2010 Feb; 37(2):571-6. PubMed ID: 20229865
[TBL] [Abstract][Full Text] [Related]
17. Radiochromic film dosimetry with flatbed scanners: a fast and accurate method for dose calibration and uniformity correction with single film exposure.
Menegotti L; Delana A; Martignano A
Med Phys; 2008 Jul; 35(7):3078-85. PubMed ID: 18697531
[TBL] [Abstract][Full Text] [Related]
18. Absorption spectra of irradiated XRCT radiochromic film.
Butson MJ; Cheung T; Yu PK
Phys Med Biol; 2006 Jun; 51(12):3099-103. PubMed ID: 16757865
[TBL] [Abstract][Full Text] [Related]
19. Radiochromic film dosimetry: considerations on precision and accuracy for EBT2 and EBT3 type films.
Dreindl R; Georg D; Stock M
Z Med Phys; 2014 May; 24(2):153-63. PubMed ID: 24055395
[TBL] [Abstract][Full Text] [Related]
20. The use of new GAFCHROMIC EBT film for 125I seed dosimetry in Solid Water phantom.
Chiu-Tsao ST; Medich D; Munro J
Med Phys; 2008 Aug; 35(8):3787-99. PubMed ID: 18777938
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]