These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

156 related articles for article (PubMed ID: 22248372)

  • 1. Single and inappropriate shock delivered out of tachycardia: device dysfunction?
    Fontenla A; Carrero D; Salguero R; López-Gil M; De Riva M; Arribas F
    Pacing Clin Electrophysiol; 2012 Jul; 35(7):884-6. PubMed ID: 22248372
    [No Abstract]   [Full Text] [Related]  

  • 2. A "shocking" case rectified.
    Van Heuverswyn F; Timmers L; Combes M; Stroobandt R
    Pacing Clin Electrophysiol; 2014 Mar; 37(3):379-82. PubMed ID: 23875996
    [No Abstract]   [Full Text] [Related]  

  • 3. Shock-induced ventricular tachycardia: what is the mechanism?
    Santangeli P; Hsia HH; Wang PJ; Al-Ahmad A
    Pacing Clin Electrophysiol; 2014 Apr; 37(4):516-9. PubMed ID: 23980924
    [No Abstract]   [Full Text] [Related]  

  • 4. Repetitive Periodic Atrial Oversensing in a Cardiac Implantable Electrical Defibrillator at 35 Minutes and 50 Minutes Past the Hour: What Is the Diagnosis?
    Hu YL; Kaszala K; Huizar J; Ellenbogen KA; Tan AY
    Pacing Clin Electrophysiol; 2016 Sep; 39(9):1018-21. PubMed ID: 27356808
    [No Abstract]   [Full Text] [Related]  

  • 5. Inappropriate shocks or inappropriate programming? A review of Guidant's reconfirmation algorithm.
    Mansour F; Guash E; Berruezo A; Brugada J; Tolosana JM; Mont L
    Europace; 2009 Aug; 11(8):1120-2. PubMed ID: 19443435
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Induction of ventricular tachycardia by alternate current due to an insufficiently grounded electrical system.
    Lappegård KT
    Pacing Clin Electrophysiol; 2012 Jun; 35(6):e170-2. PubMed ID: 21091734
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Repetitive Implantable Cardioverter Defibrillator Shocks: What is the Mechanism?
    Iwasawa J; Miyazaki S; Hachiya H; Iesaka Y
    Pacing Clin Electrophysiol; 2015 Jul; 38(7):899-901. PubMed ID: 26132722
    [No Abstract]   [Full Text] [Related]  

  • 8. ICD proarrhythmia as a consequence of an interaction with an algorithm to prevent atrial arrhythmias.
    Martínez-Sánchez J; García-Alberola A; Sánchez-Muñoz JJ; Peñafiel-Verdú P; Giner-Caro JA; Valdés-Chávarri M
    Pacing Clin Electrophysiol; 2009 Aug; 32(8):1096-8. PubMed ID: 19659632
    [TBL] [Abstract][Full Text] [Related]  

  • 9. How to prevent ICD shocks: part I.
    Buck S; Maass AH; Van Gelder IC
    Europace; 2008 Sep; 10(9):1110-1. PubMed ID: 18710855
    [No Abstract]   [Full Text] [Related]  

  • 10. How to prevent ICD shocks: part II.
    Buck S; Maass AH; Van Gelder IC
    Europace; 2008 Sep; 10(9):1126-9. PubMed ID: 18710856
    [No Abstract]   [Full Text] [Related]  

  • 11. Repetitive non-reentrant VA synchrony and pacemaker-mediated tachycardia induced by the AF suppression algorithm.
    Kohno R; Abe H; Nagatomo T; Otsuji Y
    Pacing Clin Electrophysiol; 2009 Oct; 32(10):1333-5. PubMed ID: 19732366
    [No Abstract]   [Full Text] [Related]  

  • 12. Inappropriate Shocks in a Patient with Subcutaneous ICD and Transvenous Pacemaker: Is it as it Seems?
    Santucci LM; Saputo FA; Verticelli L; Tamburri I; Placidi S; Silvetti MS; Drago F
    Pacing Clin Electrophysiol; 2016 Aug; 39(8):873-5. PubMed ID: 27198130
    [No Abstract]   [Full Text] [Related]  

  • 13. Troubleshooting of small R-wave with inappropriate implantable cardioverter-defibrillator shock.
    Baldinger SH; Kadner A; Delacrétaz E
    Europace; 2014 Jun; 16(6):854. PubMed ID: 24008497
    [No Abstract]   [Full Text] [Related]  

  • 14. Programming implantable cardioverter-defibrillators in primary prevention: higher or later.
    Clementy N; Pierre B; Simeon E; Lallemand B; Fauchier L; Babuty D
    Arch Cardiovasc Dis; 2014 May; 107(5):308-18. PubMed ID: 24834904
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Inappropriate shock: a failure of SVT discriminators in a dual chamber ICD?
    Al-Ahmad A; Tsiperfal A; Hsia HH; Wang PJ
    Pacing Clin Electrophysiol; 2006 Dec; 29(12):1413-5. PubMed ID: 17201851
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Avoidance of electromagnetic interference to implantable cardiovertor-defibrillator during atrioventricular node ablation for atrial fibrillation using transvenous cryoablation.
    Siu CW; Tse HF; Lau CP
    Pacing Clin Electrophysiol; 2006 Aug; 29(8):914-6. PubMed ID: 16923011
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A new mechanism for inappropriate therapy observed during recommended device software upgrade of a St Jude Medical Fortify ST™ implantable cardioverter-defibrillator.
    Sandgaard NC; Johansen JB
    Europace; 2014 Jan; 16(1):80. PubMed ID: 23858020
    [No Abstract]   [Full Text] [Related]  

  • 18. Making sense of the new ICD algorithms for the treatment of fast ventricular tachycardia.
    Barold SS; Herweg B
    Pacing Clin Electrophysiol; 2009 Feb; 32(2):149-52. PubMed ID: 19170901
    [No Abstract]   [Full Text] [Related]  

  • 19. Simultaneous spontaneous onset of ventricular tachycardia and termination of atrial fibrillation.
    Osman F; Ward R; Morley-Davies A
    Europace; 2008 Feb; 10(2):171-2. PubMed ID: 18203735
    [No Abstract]   [Full Text] [Related]  

  • 20. Failure of an ICD to Deliver Antitachycardia Therapy against Recurrent, Sustained Ventricular Tachycardia: What's the Mechanism?
    Willoughby MC; Diamantakos E; Dorman AK; Pires LA
    Pacing Clin Electrophysiol; 2016 Jan; 39(1):95-8. PubMed ID: 26310862
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 8.