BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

159 related articles for article (PubMed ID: 22251167)

  • 1. Comparison of corticosterone responses to acute stressors: chronic jugular vein versus trunk blood samples in mice.
    Nyuyki KD; Maloumby R; Reber SO; Neumann ID
    Stress; 2012 Nov; 15(6):618-26. PubMed ID: 22251167
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparative analysis of ACTH and corticosterone sampling methods in rats.
    Vahl TP; Ulrich-Lai YM; Ostrander MM; Dolgas CM; Elfers EE; Seeley RJ; D'Alessio DA; Herman JP
    Am J Physiol Endocrinol Metab; 2005 Nov; 289(5):E823-8. PubMed ID: 15956051
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of the stress response in rats to repeated isoflurane or CO2:O2 anesthesia used for restraint during serial blood collection via the jugular vein.
    Altholtz LY; Fowler KA; Badura LL; Kovacs MS
    J Am Assoc Lab Anim Sci; 2006 May; 45(3):17-22. PubMed ID: 16642965
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Blood sampling technique for measurement of plasma arginine vasopressin concentration in conscious and unrestrained rats.
    Suzuki K; Koizumi N; Hirose H; Hokao R; Takemura N; Motoyoshi S
    Lab Anim Sci; 1997 Apr; 47(2):190-3. PubMed ID: 9150500
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of coagulation test results for blood samples obtained by means of direct venipuncture and through a jugular vein catheter in clinically normal dogs.
    Millis DL; Hawkins E; Jager M; Boyle CR
    J Am Vet Med Assoc; 1995 Nov; 207(10):1311-4. PubMed ID: 7591925
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Cannulation of the jugular vein in mice: a method for serial withdrawal of blood samples.
    Bardelmeijer HA; Buckle T; Ouwehand M; Beijnen JH; Schellens JH; van Tellingen O
    Lab Anim; 2003 Jul; 37(3):181-7. PubMed ID: 12869279
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A non-surgical jugular catheterization technique for multiple blood sampling in cats.
    Albarellos GA; Bonafine RR; Kreil VE; Ambros LA; Montoya L; Hallu RE
    Lab Anim; 2003 Jul; 37(3):188-92. PubMed ID: 12869280
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Serum corticosterone and blood glucose in rats after two jugular vein blood sampling methods: comparison of the stress response.
    Vachon P; Moreau JP
    Contemp Top Lab Anim Sci; 2001 Sep; 40(5):22-4. PubMed ID: 11560401
    [TBL] [Abstract][Full Text] [Related]  

  • 9. High plasma corticosterone levels persist during frequent automatic blood sampling in rats.
    Abelson KS; Adem B; Royo F; Carlsson HE; Hau J
    In Vivo; 2005; 19(5):815-9. PubMed ID: 16097432
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Validation of a refined technique for taking repeated blood samples from juvenile and adult mice.
    Sadler AM; Bailey SJ
    Lab Anim; 2013 Oct; 47(4):316-9. PubMed ID: 23828854
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effects of anesthesia and blood sampling techniques on plasma metabolites and corticosterone in the rat.
    Arnold M; Langhans W
    Physiol Behav; 2010 Apr; 99(5):592-8. PubMed ID: 20152845
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A simple procedure to secure an indwelling jugular vein catheter to the neck of cattle for repeated blood sampling.
    Zalkovic P; MacLean MA; Ambrose DJ
    Can Vet J; 2001 Dec; 42(12):940-2. PubMed ID: 11769620
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A fast and simple technique for jugular catheterization in adult sows.
    Zanella AJ; Mendl MT
    Lab Anim; 1992 Jul; 26(3):211-3. PubMed ID: 1501436
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A jugular bleeding technique in rabbits.
    Nelson EA; Keller GL; Mitchell TW; Pennypacker B; Rebbeck P; Rogers IT
    Lab Anim (NY); 2010 Jan; 39(1):17-22. PubMed ID: 20023677
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Baseline and stress-induced plasma corticosterone concentrations of mice selectively bred for high voluntary wheel running.
    Malisch JL; Saltzman W; Gomes FR; Rezende EL; Jeske DR; Garland T
    Physiol Biochem Zool; 2007; 80(1):146-56. PubMed ID: 17160887
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of clinical pathology parameters with two different blood sampling techniques in rats: retrobulbar plexus versus sublingual vein.
    Mahl A; Heining P; Ulrich P; Jakubowski J; Bobadilla M; Zeller W; Bergmann R; Singer T; Meister L
    Lab Anim; 2000 Oct; 34(4):351-61. PubMed ID: 11072855
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Simultaneous sampling of portal, hepatic and systemic blood during intragastric loading and tracer infusion in conscious pigs.
    Olesen HP; Sjøntoft E; Tronier B
    Lab Anim Sci; 1989 Sep; 39(5):429-32. PubMed ID: 2530399
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Surgical vascular access in the porcine model for long-term repeated blood sampling.
    Lombardo C; Damiano G; Cassata G; Palumbo VD; Cacciabaudo F; Spinelii G; Calvagna C; Gioviale MC; Maione CL; Lo Monte AI
    Acta Biomed; 2010 Sep; 81(2):101-3. PubMed ID: 21309130
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Non-surgical catheterization of the jugular vein in young pigs.
    Carroll JA; Daniel JA; Keisler DH; Matteri RL
    Lab Anim; 1999 Apr; 33(2):129-34. PubMed ID: 10780815
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Individual variation in corticosterone secretion in laying hens.
    Littin KE; Cockrem JF
    Br Poult Sci; 2001 Sep; 42(4):536-46. PubMed ID: 11572631
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.