BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 22254725)

  • 1. Transcranial magnetic stimulation coil with electronically switchable active and sham modes.
    Deng ZD; Peterchev AV
    Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():1993-6. PubMed ID: 22254725
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Coil design considerations for deep-brain transcranial magnetic stimulation (dTMS).
    Deng ZD; Peterchev AV; Lisanby SH
    Annu Int Conf IEEE Eng Med Biol Soc; 2008; 2008():5675-9. PubMed ID: 19164005
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Coil design for real and sham transcranial magnetic stimulation.
    Ruohonen J; Ollikainen M; Nikouline V; Virtanen J; Ilmoniemi RJ
    IEEE Trans Biomed Eng; 2000 Feb; 47(2):145-8. PubMed ID: 10721620
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A real electro-magnetic placebo (REMP) device for sham transcranial magnetic stimulation (TMS).
    Rossi S; Ferro M; Cincotta M; Ulivelli M; Bartalini S; Miniussi C; Giovannelli F; Passero S
    Clin Neurophysiol; 2007 Mar; 118(3):709-16. PubMed ID: 17188568
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Electronically switchable sham transcranial magnetic stimulation (TMS) system.
    Hoeft F; Wu DA; Hernandez A; Glover GH; Shimojo S
    PLoS One; 2008 Apr; 3(4):e1923. PubMed ID: 18398456
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Iron-core coils for transcranial magnetic stimulation.
    Epstein CM; Davey KR
    J Clin Neurophysiol; 2002 Aug; 19(4):376-81. PubMed ID: 12436092
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Electric field depth-focality tradeoff in transcranial magnetic stimulation: simulation comparison of 50 coil designs.
    Deng ZD; Lisanby SH; Peterchev AV
    Brain Stimul; 2013 Jan; 6(1):1-13. PubMed ID: 22483681
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Repetitive transcranial magnetic stimulator with controllable pulse parameters.
    Peterchev AV; Murphy DL; Lisanby SH
    J Neural Eng; 2011 Jun; 8(3):036016. PubMed ID: 21540487
    [TBL] [Abstract][Full Text] [Related]  

  • 9. High permeability cores to optimize the stimulation of deeply located brain regions using transcranial magnetic stimulation.
    Salvador R; Miranda PC; Roth Y; Zangen A
    Phys Med Biol; 2009 May; 54(10):3113-28. PubMed ID: 19420425
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Transcranial magnetic stimulation--a sandwich coil design for a better sham.
    Sommer J; Jansen A; Dräger B; Steinsträter O; Breitenstein C; Deppe M; Knecht S
    Clin Neurophysiol; 2006 Feb; 117(2):440-6. PubMed ID: 16376141
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A transcranial magnetic stimulator inducing near-rectangular pulses with controllable pulse width (cTMS).
    Peterchev AV; Jalinous R; Lisanby SH
    IEEE Trans Biomed Eng; 2008 Jan; 55(1):257-66. PubMed ID: 18232369
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Minimum-energy coils for transcranial magnetic stimulation: application to focal stimulation.
    Koponen LM; Nieminen JO; Ilmoniemi RJ
    Brain Stimul; 2015; 8(1):124-34. PubMed ID: 25458713
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Three-dimensional distribution of the electric field induced in the brain by transcranial magnetic stimulation using figure-8 and deep H-coils.
    Roth Y; Amir A; Levkovitz Y; Zangen A
    J Clin Neurophysiol; 2007 Feb; 24(1):31-8. PubMed ID: 17277575
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Coil design considerations for deep transcranial magnetic stimulation.
    Deng ZD; Lisanby SH; Peterchev AV
    Clin Neurophysiol; 2014 Jun; 125(6):1202-12. PubMed ID: 24411523
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Transcranial magnetic stimulation of small animals: a modeling study of the influence of coil geometry, size and orientation.
    Salvador R; Miranda PC
    Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():674-7. PubMed ID: 19964482
    [TBL] [Abstract][Full Text] [Related]  

  • 16. MR-based measurements and simulations of the magnetic field created by a realistic transcranial magnetic stimulation (TMS) coil and stimulator.
    Mandija S; Petrov PI; Neggers SF; Luijten PR; van den Berg CA
    NMR Biomed; 2016 Nov; 29(11):1590-1600. PubMed ID: 27669678
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Design of a dynamic transcranial magnetic stimulation coil system.
    Ge S; Jiang R; Wang R; Chen J
    J Med Syst; 2014 Aug; 38(8):64. PubMed ID: 24957390
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effects of TMS coil geometry on stimulation specificity.
    Talebinejad M; Musallam S
    Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():1507-10. PubMed ID: 21096368
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Improved field localization in transcranial magnetic stimulation of the brain with the utilization of a conductive shield plate in the stimulator.
    Kim DH; Georghiou GE; Won C
    IEEE Trans Biomed Eng; 2006 Apr; 53(4):720-5. PubMed ID: 16602579
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Design of transcranial magnetic stimulation coils with optimal trade-off between depth, focality, and energy.
    Gomez LJ; Goetz SM; Peterchev AV
    J Neural Eng; 2018 Aug; 15(4):046033. PubMed ID: 29855433
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.