These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

229 related articles for article (PubMed ID: 22255924)

  • 1. Telefetalcare: a first prototype of a wearable fetal electrocardiograph.
    Fanelli A; Signorini MG; Ferrario M; Perego P; Piccini L; Andreoni G; Magenes G
    Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():6899-902. PubMed ID: 22255924
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Heart rate detection in low amplitude non-invasive fetal ECG recordings.
    Peters C; Vullings R; Bergmans J; Oei G; Wijn P
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():6092-4. PubMed ID: 17946740
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Fetal ECG extraction via Type-2 adaptive neuro-fuzzy inference systems.
    Ahmadieh H; Asl BM
    Comput Methods Programs Biomed; 2017 Apr; 142():101-108. PubMed ID: 28325438
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A novel LabVIEW-based multi-channel non-invasive abdominal maternal-fetal electrocardiogram signal generator.
    Martinek R; Kelnar M; Koudelka P; Vanus J; Bilik P; Janku P; Nazeran H; Zidek J
    Physiol Meas; 2016 Feb; 37(2):238-56. PubMed ID: 26799770
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Single-lead noninvasive fetal ECG extraction by means of combining clustering and principal components analysis.
    Zhang Y; Yu S
    Med Biol Eng Comput; 2020 Feb; 58(2):419-432. PubMed ID: 31858419
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Fetal Heart Rate Monitoring Using Maternal Abdominal Surface Electrodes in Third Trimester: Can We Obtain Additional Information Other than CTG Trace?
    Fuchs T; Grobelak K; Pomorski M; Zimmer M
    Adv Clin Exp Med; 2016; 25(2):309-16. PubMed ID: 27627565
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Extraction of foetal ECG from abdominal ECG by nonlinear transformation and estimations.
    John RG; Ramachandran KI
    Comput Methods Programs Biomed; 2019 Jul; 175():193-204. PubMed ID: 31104707
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Beat-to-beat heart rate detection in multi-lead abdominal fetal ECG recordings.
    Peters CH; van Laar JO; Vullings R; Oei SG; Wijn PF
    Med Eng Phys; 2012 Apr; 34(3):333-8. PubMed ID: 21893425
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Fetal electrocardiogram enhancement in abdominal recordings: recording setup analysis.
    Taralunga DD; MihaelaUngureanu G; Hurezeanu PB; Gussi I; Strungaru R; Wolf W
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():1907-10. PubMed ID: 24110085
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Feasibility of non-invasive Foetal electrocardiography in a twin pregnancy.
    Noben L; Westerhuis MEMH; van Laar JOEH; Kok RD; Oei SG; Peters CHL; Vullings R
    BMC Pregnancy Childbirth; 2020 Apr; 20(1):215. PubMed ID: 32293330
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Noninvasive fetal electrocardiography: an overview of the signal electrophysiological meaning, recording procedures, and processing techniques.
    Agostinelli A; Grillo M; Biagini A; Giuliani C; Burattini L; Fioretti S; Di Nardo F; Giannubilo SR; Ciavattini A; Burattini L
    Ann Noninvasive Electrocardiol; 2015 Jul; 20(4):303-13. PubMed ID: 25640061
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Prototype of a wearable system for remote fetal monitoring during pregnancy.
    Fanelli A; Ferrario M; Piccini L; Andreoni G; Matrone G; Magenes G; Signorini MG
    Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():5815-8. PubMed ID: 21096913
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Morphology extraction of fetal ECG using temporal CNN-based nonlinear adaptive noise cancelling.
    Cao S; Xiao H; Gong G; Fang W; Chen C
    PLoS One; 2022; 17(12):e0278917. PubMed ID: 36520789
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Non-invasive acquisition of fetal ECG from the maternal xyphoid process: a feasibility study in pregnant sheep and a call for open data sets.
    Shen C; Frasch MG; Wu HT; Herry CL; Cao M; Desrochers A; Fecteau G; Burns P
    Physiol Meas; 2018 Mar; 39(3):035005. PubMed ID: 29369821
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Systematic analysis of single- and multi-reference adaptive filters for non-invasive fetal electrocardiography.
    Sulas E; Urru M; Tumbarello R; Raffo L; Pani D
    Math Biosci Eng; 2019 Oct; 17(1):286-308. PubMed ID: 31731352
    [TBL] [Abstract][Full Text] [Related]  

  • 16. QRS classification and spatial combination for robust heart rate detection in low-quality fetal ECG recordings.
    Warmerdam G; Vullings R; Van Pul C; Andriessen P; Oei SG; Wijn P
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():2004-7. PubMed ID: 24110110
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dynamic segmentation and linear prediction for maternal ECG removal in antenatal abdominal recordings.
    Vullings R; Peters CH; Sluijter RJ; Mischi M; Oei SG; Bergmans JW
    Physiol Meas; 2009 Mar; 30(3):291-307. PubMed ID: 19223679
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Fetal QRS extraction from abdominal recordings via model-based signal processing and intelligent signal merging.
    Haghpanahi M; Borkholder DA
    Physiol Meas; 2014 Aug; 35(8):1591-605. PubMed ID: 25069479
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Noninvasive fetal ECG extraction using doubly constrained block-term decomposition.
    Mousavian I; Shamsollahi MB; Fatemizadeh E
    Math Biosci Eng; 2019 Sep; 17(1):144-159. PubMed ID: 31731344
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Improved equipment for abdominal fetal electrocardiogram recording: description and clinical evaluation.
    Cicinelli E; Bortone A; Carbonara I; Incampo G; Bochicchio M; Ventura G; Montanaro S; Aloisio G
    Int J Biomed Comput; 1994 Apr; 35(3):193-205. PubMed ID: 8005712
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.