BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

1538 related articles for article (PubMed ID: 22256968)

  • 1. Detection of human Enterovirus 71 reverse transcription loop-mediated isothermal amplification (RT-LAMP).
    Yaqing H; Wenping Z; Zhiyi Y; Xionghu W; Shouyi Y; Hong Y; Yingchun D; Guifang H
    Lett Appl Microbiol; 2012 Mar; 54(3):233-9. PubMed ID: 22256968
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Development and evaluation of reverse transcription-loop-mediated isothermal amplification assay for rapid detection of enterovirus 71.
    Shi W; Li K; Ji Y; Jiang Q; Shi M; Mi Z
    BMC Infect Dis; 2011 Jul; 11():197. PubMed ID: 21767352
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Improved detection limit in rapid detection of human enterovirus 71 and coxsackievirus A16 by a novel reverse transcription-isothermal multiple-self-matching-initiated amplification assay.
    Ding X; Nie K; Shi L; Zhang Y; Guan L; Zhang D; Qi S; Ma X
    J Clin Microbiol; 2014 Jun; 52(6):1862-70. PubMed ID: 24648558
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Rapid and visual detection of human enterovirus coxsackievirus A16 by reverse transcription loop-mediated isothermal amplification combined with lateral flow device.
    Yan G; Jun L; Kangchen Z; Yiyue G; Yang Y; Xiaoyu Z; Zhiyang S; Lunbiao C
    Lett Appl Microbiol; 2015 Dec; 61(6):531-7. PubMed ID: 26399963
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of a direct reverse transcription loop-mediated isothermal amplification method without RNA extraction for the detection of human enterovirus 71 subgenotype C4 in nasopharyngeal swab specimens.
    Nie K; Qi SX; Zhang Y; Luo L; Xie Y; Yang MJ; Zhang Y; Li J; Shen H; Li Q; Ma XJ
    PLoS One; 2012; 7(12):e52486. PubMed ID: 23272248
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A tailored reverse transcription loop-mediated isothermal amplification for sensitive and specific detection of serotype A foot-and-mouth disease virus circulating in pool 1 region countries.
    Lim DR; Kim HR; Park MJ; Chae HG; Ku BK; Nah JJ; Ryoo S; Wee SH; Park CK
    Transbound Emerg Dis; 2018 Dec; 65(6):1898-1908. PubMed ID: 30054975
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Simple and rapid detection of human enterovirus 71 by reverse-transcription and loop-mediated isothermal amplification: cryopreservation affected the detection ability.
    Xia JF; Yan XF; Yu H; Qu D; Long JE
    Diagn Microbiol Infect Dis; 2011 Nov; 71(3):244-51. PubMed ID: 21899976
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Detection of enterovirus 71 gene from clinical specimens by reverse-transcription loop-mediated isothermal amplification.
    Wang D; Wang X; Geng Y; An C
    Indian J Med Microbiol; 2014; 32(2):124-9. PubMed ID: 24713896
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Applicability of duplex real time and lateral flow strip reverse-transcription recombinase aided amplification assays for the detection of Enterovirus 71 and Coxsackievirus A16.
    Li XN; Shen XX; Li MH; Qi JJ; Wang RH; Duan QX; Zhang RQ; Fan T; Bai XD; Fan GH; Xie Y; Ma XJ
    Virol J; 2019 Dec; 16(1):166. PubMed ID: 31888694
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Detection of enterovirus 71 using reverse transcription loop-mediated isothermal amplification (RT-LAMP).
    Wang X; Zhu JP; Zhang Q; Xu ZG; Zhang F; Zhao ZH; Zheng WZ; Zheng LS
    J Virol Methods; 2012 Feb; 179(2):330-4. PubMed ID: 22155579
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A one-step, triplex, real-time RT-PCR assay for the simultaneous detection of enterovirus 71, coxsackie A16 and pan-enterovirus in a single tube.
    Zhang S; Wang J; Yan Q; He S; Zhou W; Ge S; Xia N
    PLoS One; 2014; 9(7):e102724. PubMed ID: 25029500
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Development and evaluation of a rapid recombinase polymerase amplification assay for the detection of human enterovirus 71.
    Yin D; Zhu Y; Wang K; Wang J; Zhang X; Han M; He Y; Chen Q; Hu G
    Arch Virol; 2018 Sep; 163(9):2459-2463. PubMed ID: 29767300
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Colorimetric detection of coxsackievirus A6 by reverse transcription loop mediated isothermal amplification].
    Guan L; Xu S; Nie K; Zhang D; Li X; Xu W; Ma X
    Zhonghua Yu Fang Yi Xue Za Zhi; 2015 Nov; 49(11):1009-13. PubMed ID: 26833014
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An improved reverse transcription loop-mediated isothermal amplification assay for sensitive and specific detection of serotype O foot-and-mouth disease virus.
    Lim DR; Kim HR; Park MJ; Chae HG; Ku BK; Nah JJ; Ryoo SY; Wee SH; Park YR; Jeon HS; Kim JJ; Jeon BY; Lee HW; Yeo SG; Park CK
    J Virol Methods; 2018 Oct; 260():6-13. PubMed ID: 29964077
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of a rapid detection for Coxsackievirus B3 using one-step reverse transcription loop-mediated isothermal amplification (RT-LAMP).
    Monazah A; Zeinoddini M; Saeeidinia AR
    J Virol Methods; 2017 Aug; 246():27-33. PubMed ID: 28435073
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Rapid detection of peste des petits ruminants virus by a reverse transcription loop-mediated isothermal amplification assay.
    Li L; Bao J; Wu X; Wang Z; Wang J; Gong M; Liu C; Li J
    J Virol Methods; 2010 Dec; 170(1-2):37-41. PubMed ID: 20813134
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Development and evaluation of a reverse transcription-loop-mediated isothermal amplification assay for rapid detection of enterovirus 71.
    Jiang T; Liu J; Deng YQ; Xu LJ; Li XF; Han JF; Cao RY; Qin ED; Qin CF
    J Clin Microbiol; 2011 Mar; 49(3):870-4. PubMed ID: 21177907
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Development of a highly sensitive real-time nested RT-PCR assay in a single closed tube for detection of enterovirus 71 in hand, foot, and mouth disease.
    Niu P; Qi S; Yu B; Zhang C; Wang J; Li Q; Ma X
    Arch Virol; 2016 Nov; 161(11):3003-10. PubMed ID: 27475103
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Development of a new method for diagnosis of Group B Coxsackie genome by reverse transcription loop-mediated isothermal amplification.
    Jaianand K; Saravanan N; Gunasekaran P; Sheriff AK
    Indian J Med Microbiol; 2011; 29(2):110-7. PubMed ID: 21654103
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Colorimetric detection of human influenza A H1N1 virus by reverse transcription loop mediated isothermal amplification].
    Nie K; Wang DY; Qin M; Gao RB; Wang M; Zou SM; Han F; Zhao X; Li XY; Shu YL; Ma XJ
    Bing Du Xue Bao; 2010 Mar; 26(2):81-7. PubMed ID: 20480635
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 77.