BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

139 related articles for article (PubMed ID: 22258638)

  • 1. Indirect measurement of pinch and pull forces at the shaft of laparoscopic graspers.
    Dobbelsteen JJ; Lee RA; Noorden Mv; Dankelman J
    Med Biol Eng Comput; 2012 Mar; 50(3):215-21. PubMed ID: 22258638
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The optimal mechanical efficiency of laparoscopic forceps.
    Heijnsdijk EA; Pasdeloup A; Dankelman J; Gouma DJ
    Surg Endosc; 2004 Dec; 18(12):1766-70. PubMed ID: 15809786
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of laparoscopic grasper force transmission ratio on grasp control.
    Westebring-van der Putten EP; van den Dobbelsteen JJ; Goossens RH; Jakimowicz JJ; Dankelman J
    Surg Endosc; 2009 Apr; 23(4):818-24. PubMed ID: 18814010
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A modular force-controlled robotic instrument for minimally invasive surgery - efficacy for being used in autonomous grasping against a variable pull force.
    Khadem SM; Behzadipour S; Mirbagheri A; Farahmand F
    Int J Med Robot; 2016 Dec; 12(4):620-633. PubMed ID: 26804489
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Force-adjustable parallel-occlusion grasper.
    Khan H; Coleman S; Cuschieri A
    Int J Surg; 2024 Feb; 110(2):750-757. PubMed ID: 37995091
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Grasper having tactile sensing function using acoustic reflection for laparoscopic surgery.
    Ly HH; Tanaka Y; Fukuda T; Sano A
    Int J Comput Assist Radiol Surg; 2017 Aug; 12(8):1333-1343. PubMed ID: 28455766
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An actuated force feedback-enabled laparoscopic instrument for robotic-assisted surgery.
    Moradi Dalvand M; Shirinzadeh B; Shamdani AH; Smith J; Zhong Y
    Int J Med Robot; 2014 Mar; 10(1):11-21. PubMed ID: 23640908
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Pneumatically driven surgical instrument capable of estimating translational force and grasping force.
    Miyazaki R; Kanno T; Kawashima K
    Int J Med Robot; 2019 Jun; 15(3):e1983. PubMed ID: 30648783
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Design and Evaluation of a Balanced Compliant Laparoscopic Grasper.
    Klok JW; Postema R; Steinporsson AT; Dankelman J; Horeman T
    IEEE J Transl Eng Health Med; 2023; 11():451-459. PubMed ID: 37817822
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Design of a multifunctional compliant instrument for minimally invasive surgery.
    Frecker MI; Powell KM; Haluck R
    J Biomech Eng; 2005 Nov; 127(6):990-3. PubMed ID: 16438237
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Friction dynamics of trocars.
    van den Dobbelsteen JJ; Schooleman A; Dankelman J
    Surg Endosc; 2007 Aug; 21(8):1338-43. PubMed ID: 17165115
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Stiffness Assessment and Lump Detection in Minimally Invasive Surgery Using In-House Developed Smart Laparoscopic Forceps.
    Othman W; Vandyck KE; Abril C; Barajas-Gamboa JS; Pantoja JP; Kroh M; Qasaimeh MA
    IEEE J Transl Eng Health Med; 2022; 10():2500410. PubMed ID: 35774413
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Slip and damage properties of jaws of laparoscopic graspers.
    Heijnsdijk EA; de Visser H; Dankelman J; Gouma DJ
    Surg Endosc; 2004 Jun; 18(6):974-9. PubMed ID: 15108111
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Force-feedback grasper helps restore sense of touch in minimally invasive surgery.
    MacFarlane M; Rosen J; Hannaford B; Pellegrini C; Sinanan M
    J Gastrointest Surg; 1999; 3(3):278-85. PubMed ID: 10481120
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Design and feasibility of PASSIST, a passive instrument positioner.
    Jaspers JE; Den Boer KT; Sjoerdsma W; Bruijn M; Grimbergen CA
    J Laparoendosc Adv Surg Tech A; 2000 Dec; 10(6):331-5. PubMed ID: 11132913
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Factors influencing forces during laparoscopic pinching: Towards the design of virtual simulator.
    Susmitha WK; Mathew G; Devasahayam SR; Perakath B; Velusamy SK
    Int J Surg; 2015 Jun; 18():211-5. PubMed ID: 25937156
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Output force and ratio of laparoscopic graspers: an evaluation of operating room ergonomics.
    Olig EM; Wilson S; Reddy M
    Am J Obstet Gynecol; 2023 Sep; 229(3):307.e1-307.e9. PubMed ID: 37201694
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Force sensing of multiple-DOF cable-driven instruments for minimally invasive robotic surgery.
    He C; Wang S; Sang H; Li J; Zhang L
    Int J Med Robot; 2014 Sep; 10(3):314-24. PubMed ID: 24030887
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Smart Laparoscopic Grasper Utilizing Force and Angle Sensors for Stiffness Assessment in Minimally Invasive Surgery
    Othman W; Qasaimeh MA
    Annu Int Conf IEEE Eng Med Biol Soc; 2021 Nov; 2021():7336-7339. PubMed ID: 34892792
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Real-Time Measurement of the Tool-Tissue Interaction in Minimally Invasive Abdominal Surgery: The First Step to Developing the Next Generation of Smart Laparoscopic Instruments.
    Barrie J; Jayne DG; Neville A; Hunter L; Hood AJ; Culmer PR
    Surg Innov; 2016 Oct; 23(5):463-8. PubMed ID: 27122481
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.