These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

86 related articles for article (PubMed ID: 22264565)

  • 1. Distal locking of femoral nails. Mathematical analysis of the appropriate targeting range.
    Moor BK; Ehlinger M; Arlettaz Y
    Orthop Traumatol Surg Res; 2012 Feb; 98(1):85-9. PubMed ID: 22264565
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Deformation of femoral nails with intramedullary insertion.
    Krettek C; Mannss J; Miclau T; Schandelmaier P; Linnemann I; Tscherne H
    J Orthop Res; 1998 Sep; 16(5):572-5. PubMed ID: 9820280
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Stress analysis of the distal locking screws for femoral interlocking nailing.
    Lin J; Lin SJ; Chen PQ; Yang SH
    J Orthop Res; 2001 Jan; 19(1):57-63. PubMed ID: 11332621
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Mechanical study of the safe distance between distal femoral fracture site and distal locking screws in antegrade intramedullary nailing.
    Antekeier SB; Burden RL; Voor MJ; Roberts CS
    J Orthop Trauma; 2005; 19(10):693-7. PubMed ID: 16314716
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Increasing nail-cortical contact to increase fixation stability and decrease implant strain in antegrade locked nailing of distal femoral fractures: a biomechanical study.
    Huang SC; Lin CC; Lin J
    J Trauma; 2009 Feb; 66(2):436-42. PubMed ID: 19065112
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Distal femoral fixation: a biomechanical comparison of trigen retrograde intramedullary (i.m.) nail, dynamic condylar screw (DCS), and locking compression plate (LCP) condylar plate.
    Heiney JP; Barnett MD; Vrabec GA; Schoenfeld AJ; Baji A; Njus GO
    J Trauma; 2009 Feb; 66(2):443-9. PubMed ID: 19204519
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Do locked compression intramedullary nails improve the biomechanical stability of distal femoral fractures?
    Wild M; Thelen S; Spoor V; Eichler C; Koebke J; Jungbluth P; Betsch M; Windolf J; Hakimi M
    J Trauma; 2011 Apr; 70(4):832-7. PubMed ID: 21248651
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biomechanical analysis of titanium elastic nail fixation in a pediatric femur fracture model.
    Li Y; Stabile KJ; Shilt JS
    J Pediatr Orthop; 2008 Dec; 28(8):874-8. PubMed ID: 19034181
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A biomechanical investigation of the effects of static fixation and dynamization after interlocking femoral nailing: a finite element study.
    Shih KS; Hsu CC; Hsu TP
    J Trauma Acute Care Surg; 2012 Feb; 72(2):E46-53. PubMed ID: 22327998
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biomechanical comparison of expandable and locked intramedullary femoral nails.
    Oliveira ML; Lemon MA; Mears SC; Dinah AF; Waites MD; Knight TA; Belkoff SM
    J Orthop Trauma; 2008 Aug; 22(7):446-50. PubMed ID: 18670283
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Nail over nail technique for distal locking of femoral intramedullary nails.
    Rohilla R; Singh R; Magu N; Devgun A; Siwach R; Gulia A
    Int Orthop; 2009 Aug; 33(4):1107-12. PubMed ID: 18500514
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Influence of muscular contractions on the stress analysis of distal femoral interlocking nailing.
    Shih KS; Tseng CS; Lee CC; Lin SC
    Clin Biomech (Bristol, Avon); 2008 Jan; 23(1):38-44. PubMed ID: 17945402
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Literature review of current techniques for the insertion of distal screws into intramedullary locking nails.
    Whatling GM; Nokes LD
    Injury; 2006 Feb; 37(2):109-19. PubMed ID: 16310192
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Distal locking of femoral nails: evaluation of a new radiation-independent targeting system.
    Arlettaz Y; Dominguez A; Farron A; Ehlinger M; Moor BK
    J Orthop Trauma; 2012 Nov; 26(11):633-7. PubMed ID: 22473064
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Angular stability potentially permits fewer locking screws compared with conventional locking in intramedullary nailed distal tibia fractures: a biomechanical study.
    Gueorguiev B; Ockert B; Schwieger K; Wähnert D; Lawson-Smith M; Windolf M; Stoffel K
    J Orthop Trauma; 2011 Jun; 25(6):340-6. PubMed ID: 21577069
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Insertion of distal screws in interlocking nailing using a new free-hand control device].
    Pennig D; Brug E
    Unfallchirurg; 1989 Jul; 92(7):331-4. PubMed ID: 2762819
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Does the extent of prebending affect the stability of femoral shaft fractures stabilized by titanium elastic nails? A biomechanical investigation on an adolescent femur model.
    Doser A; Helwig P; Konstantinidis L; Kuminack KF; Südkamp NP; Strohm PC
    J Pediatr Orthop; 2011 Dec; 31(8):834-8. PubMed ID: 22101660
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Mechanical properties of different combinations of flexible nails in a model of a pediatric femoral fracture.
    Kiely N
    J Pediatr Orthop; 2002; 22(4):424-7. PubMed ID: 12131434
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Rotational stability of femoral osteosynthesis in femoral fractures - navigated measurements.
    Citak M; Kendoff D; Gardner MJ; Oszwald M; O'Loughlin PF; Olivier LC; Krettek C; Hüfner T; Citak M
    Technol Health Care; 2009; 17(1):25-32. PubMed ID: 19478402
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Use of locking compression plates for long bone nonunions without removing existing intramedullary nail: review of literature and our experience.
    Nadkarni B; Srivastav S; Mittal V; Agarwal S
    J Trauma; 2008 Aug; 65(2):482-6. PubMed ID: 18695487
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.