114 related articles for article (PubMed ID: 22275021)
1. Endoscopic removal of an embedded partially covered esophageal self-expandable metallic stent by overtube technique.
Yan SL; Chen CH; Yeh YH; Yueh SK
Endoscopy; 2011; 43 Suppl 2 UCTN():E400-1. PubMed ID: 22275021
[No Abstract] [Full Text] [Related]
2. Safety of endoscopic removal of self-expandable stents after treatment of benign esophageal diseases.
van Halsema EE; Wong Kee Song LM; Baron TH; Siersema PD; Vleggaar FP; Ginsberg GG; Shah PM; Fleischer DE; Ratuapli SK; Fockens P; Dijkgraaf MG; Rando G; Repici A; van Hooft JE
Gastrointest Endosc; 2013 Jan; 77(1):18-28. PubMed ID: 23261092
[TBL] [Abstract][Full Text] [Related]
3. Vocal cord paralysis due to self-expandable metal stent in the proximal esophagus.
Moreels TG; De Schepper HU; Macken EJ; Hubens GJ; Pelckmans PA
Endoscopy; 2014; 46 Suppl 1 UCTN():E155-6. PubMed ID: 24756271
[No Abstract] [Full Text] [Related]
4. Stent-in-stent technique for removal of embedded esophageal self-expanding metal stents.
Hirdes MM; Siersema PD; Houben MH; Weusten BL; Vleggaar FP
Am J Gastroenterol; 2011 Feb; 106(2):286-93. PubMed ID: 20940709
[TBL] [Abstract][Full Text] [Related]
5. Novel approach for removal of a fistulating oesophageal stent: an ileostomy.
Miller BJ; Wylie NK
ANZ J Surg; 2013 Jul; 83(7-8):585-6. PubMed ID: 23890300
[No Abstract] [Full Text] [Related]
6. Stent-in-stent technique for removal of embedded partially covered self-expanding metal stents.
DaVee T; Irani S; Leggett CL; Berzosa Corella M; Grooteman KV; Wong Kee Song LM; Wallace MB; Kozarek RA; Baron TH
Surg Endosc; 2016 Jun; 30(6):2332-41. PubMed ID: 26416379
[TBL] [Abstract][Full Text] [Related]
7. Esophageal perforation due to removal of partially covered self-expanding metal stents placed for a benign perforation or leak.
Hirdes MM; Vleggaar FP; Van der Linde K; Willems M; Totté ER; Siersema PD
Endoscopy; 2011 Feb; 43(2):156-9. PubMed ID: 21165825
[TBL] [Abstract][Full Text] [Related]
8. Stent-in-stent technique for removal of a metal stent embedded in the colon wall by using a fully covered, self-expandable metal esophageal stent (with video).
Gornals JB; Golda T; Soriano A
Gastrointest Endosc; 2012 Sep; 76(3):695-6. PubMed ID: 22154410
[No Abstract] [Full Text] [Related]
9. Expandable stents for benign esophageal disease.
Dua KS
Gastrointest Endosc Clin N Am; 2011 Jul; 21(3):359-76, vii. PubMed ID: 21684459
[TBL] [Abstract][Full Text] [Related]
10. Endoscopic removal of a broken self-expandable metal stent using the stent-in-stent technique.
Didden P; Kuipers EJ; Bruno MJ; Spaander MC
Endoscopy; 2012; 44 Suppl 2 UCTN():E232. PubMed ID: 22715009
[No Abstract] [Full Text] [Related]
11. Argon plasma coagulation: a less-expensive alternative to the "stent-in-stent" technique for removal of embedded partially covered esophageal stents.
Fiocca F; Cereatti F; Antypas P; Donatelli G
Gastrointest Endosc; 2016 Feb; 83(2):453. PubMed ID: 26358327
[No Abstract] [Full Text] [Related]
12. Tissue ingrowth in a fully covered self-expandable metallic stent (with videos).
Jaganmohan S; Raju GS
Gastrointest Endosc; 2008 Sep; 68(3):602-4. PubMed ID: 18331738
[No Abstract] [Full Text] [Related]
13. Esophageal self-expanding metallic stent (SEMS) migration: it's a topsy-turvy world.
Toussaint E; Zalcman M; Devière J; Le Moine O; Arvanitakis M
Endoscopy; 2012; 44 Suppl 2 UCTN():E352-3. PubMed ID: 23012017
[No Abstract] [Full Text] [Related]
14. Endoscopic removal of a fractured partially covered Evolution esophageal stent.
Mou S; Kaltenbach T; Yao M; Corrales CE; McGill S; Soetikno R
Endoscopy; 2012; 44 Suppl 2 UCTN():E378-9. PubMed ID: 23135973
[No Abstract] [Full Text] [Related]
15. Endoscopic retrieval of a migrated esophageal stent using another anchored esophageal stent and an enteroscopy overtube: A novel technique.
Nakahara K; Itoh F
Dig Endosc; 2015 Sep; 27(6):709. PubMed ID: 25963954
[No Abstract] [Full Text] [Related]
16. Novel removable internally fully covered self-expanding metal esophageal stent: feasibility, technique of removal, and tissue response in humans.
Eloubeidi MA; Lopes TL
Am J Gastroenterol; 2009 Jun; 104(6):1374-81. PubMed ID: 19491851
[TBL] [Abstract][Full Text] [Related]
17. New "knitted" EGIS esophageal stent allows atraumatic inside-out removal by inversion.
Suntharanathan J; Edwards DW; Mullan D; Martin DF; Laasch HU
Endoscopy; 2013; 45 Suppl 2 UCTN():E187-8. PubMed ID: 23832501
[No Abstract] [Full Text] [Related]
18. Endoscopic closure of esophagothoracocutaneous fistula with collagen plug and fibrin glue.
Solt J; Benkö I; Papp Z
Endoscopy; 2001 Jun; 33(6):556. PubMed ID: 11437055
[No Abstract] [Full Text] [Related]
19. A safe technique for removing a malpositioned covered biliary self-expandable metal stent.
Koornstra JJ; van Dullemen HM; Weersma RK
Endoscopy; 2008 Sep; 40 Suppl 2():E165. PubMed ID: 18668454
[No Abstract] [Full Text] [Related]
20. Closure of a duodenal stent-induced perforation by endoscopic stent removal and covered self-expandable metal stent placement (with video).
Small AJ; Petersen BT; Baron TH
Gastrointest Endosc; 2007 Nov; 66(5):1063-5. PubMed ID: 17767928
[No Abstract] [Full Text] [Related]
[Next] [New Search]