162 related articles for article (PubMed ID: 22275149)
1. A computational model for stress reduction at the skin-implant interface of osseointegrated prostheses.
Yerneni S; Dhaher Y; Kuiken TA
J Biomed Mater Res A; 2012 Apr; 100(4):911-7. PubMed ID: 22275149
[TBL] [Abstract][Full Text] [Related]
2. Revision Amputation with Press-Fit Osseointegration for Transfemoral Amputees.
Hoellwarth JS; Reif TJ; Rozbruch SR
JBJS Essent Surg Tech; 2022; 12(2):. PubMed ID: 36741033
[TBL] [Abstract][Full Text] [Related]
3. Transcutaneous Osseointegrated Prosthesis Systems (TOPS) for Rehabilitation After Lower Limb Loss: Surgical Pearls.
Aschoff HH; Örgel M; Sass M; Fischer DC; Mittlmeier T
JBJS Essent Surg Tech; 2024; 14(1):. PubMed ID: 38268768
[TBL] [Abstract][Full Text] [Related]
4. [3D finite element analysis of bone stress around distally osseointegrated implant for artificial limb attachment].
Zheng L; Luo J; Wang X; Chen J; Gu Z; Zhang X
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2007 Jun; 24(3):554-7. PubMed ID: 17713260
[TBL] [Abstract][Full Text] [Related]
5. Thighplasty at the Time of Stage-1 Bone-Anchored Osseointegration Surgery.
Harrington CJ; Guliyeva G; Mayerson JL; Potter BK; Forsberg JA; Souza JM
JBJS Essent Surg Tech; 2024; 14(1):. PubMed ID: 38516351
[TBL] [Abstract][Full Text] [Related]
6. Risk of failure during gait for direct skeletal attachment of a femoral prosthesis: a finite element study.
Helgason B; Pálsson H; Rúnarsson TP; Frossard L; Viceconti M
Med Eng Phys; 2009 Jun; 31(5):595-600. PubMed ID: 19150253
[TBL] [Abstract][Full Text] [Related]
7. FE stress analysis of the interface between the bone and an osseointegrated implant for amputees--implications to refine the rehabilitation program.
Lee WC; Doocey JM; Brånemark R; Adam CJ; Evans JH; Pearcy MJ; Frossard LA
Clin Biomech (Bristol, Avon); 2008 Dec; 23(10):1243-50. PubMed ID: 18809231
[TBL] [Abstract][Full Text] [Related]
8. Constructing an Osseointegrated Prosthetic Leg.
Kafedzic H; Rozbruch SR; Reif TJ; Hoellwarth JS
JBJS Essent Surg Tech; 2024; 14(1):. PubMed ID: 38406563
[TBL] [Abstract][Full Text] [Related]
9. Evaluation of bone insertion level of support teeth in class I mandibular removable partial denture associated with an osseointegrated implant: a study using finite element analysis.
Verri FR; Pellizzer EP; Pereira JA; Zuim PR; Santiago Júnior JF
Implant Dent; 2011 Jun; 20(3):192-201. PubMed ID: 21613946
[TBL] [Abstract][Full Text] [Related]
10. Real-time patient-specific finite element analysis of internal stresses in the soft tissues of a residual limb: a new tool for prosthetic fitting.
Portnoy S; Yarnitzky G; Yizhar Z; Kristal A; Oppenheim U; Siev-Ner I; Gefen A
Ann Biomed Eng; 2007 Jan; 35(1):120-35. PubMed ID: 17120139
[TBL] [Abstract][Full Text] [Related]
11. Numeric simulation of time-dependent remodeling of bone around loaded oral implants.
Eser A; Tonuk E; Akca K; Cehreli MC
Int J Oral Maxillofac Implants; 2009; 24(4):597-608. PubMed ID: 19885399
[TBL] [Abstract][Full Text] [Related]
12. Finite element analysis of stress-breaking attachments on maxillary implant-retained overdentures.
Tanino F; Hayakawa I; Hirano S; Minakuchi S
Int J Prosthodont; 2007; 20(2):193-8. PubMed ID: 17455444
[TBL] [Abstract][Full Text] [Related]
13. Effects of implant surface roughness and stiffness of grafted bone on an immediately loaded maxillary implant: a 3D numerical analysis.
Huang HL; Fuh LJ; Hsu JT; Tu MG; Shen YW; Wu CL
J Oral Rehabil; 2008 Apr; 35(4):283-90. PubMed ID: 18321264
[TBL] [Abstract][Full Text] [Related]
14. The effects of implant length and diameter prior to and after osseointegration: a 2-D finite element analysis.
Georgiopoulos B; Kalioras K; Provatidis C; Manda M; Koidis P
J Oral Implantol; 2007; 33(5):243-56. PubMed ID: 17987856
[TBL] [Abstract][Full Text] [Related]
15. Use of micro-CT-based finite element analysis to accurately quantify peri-implant bone strains: a validation in rat tibiae.
Torcasio A; Zhang X; Van Oosterwyck H; Duyck J; van Lenthe GH
Biomech Model Mechanobiol; 2012 May; 11(5):743-50. PubMed ID: 21898099
[TBL] [Abstract][Full Text] [Related]
16. Evaluating antimicrobials and implant materials for infection prevention around transcutaneous osseointegrated implants in a rabbit model.
Chou TG; Petti CA; Szakacs J; Bloebaum RD
J Biomed Mater Res A; 2010 Mar; 92(3):942-52. PubMed ID: 19291687
[TBL] [Abstract][Full Text] [Related]
17. Multi-body simulation of various falling scenarios for determining resulting loads at the prosthesis interface of transfemoral amputees with osseointegrated fixation.
Welke B; Schwarze M; Hurschler C; Calliess T; Seehaus F
J Orthop Res; 2013 Jul; 31(7):1123-9. PubMed ID: 23494733
[TBL] [Abstract][Full Text] [Related]
18. The influence of implant diameter and length on stress distribution of osseointegrated implants related to crestal bone geometry: a three-dimensional finite element analysis.
Baggi L; Cappelloni I; Di Girolamo M; Maceri F; Vairo G
J Prosthet Dent; 2008 Dec; 100(6):422-31. PubMed ID: 19033026
[TBL] [Abstract][Full Text] [Related]
19. Finite element analysis of bone stress and strain around a distal osseointegrated implant for prosthetic limb attachment.
Xu W; Crocombe AD; Hughes SC
Proc Inst Mech Eng H; 2000; 214(6):595-602. PubMed ID: 11201407
[TBL] [Abstract][Full Text] [Related]
20. Does migration of osseointegrated implants for transfemoral amputees predict later revision? A prospective 2-year radiostereometric analysis with 5-years clinical follow-up.
Hansen RL; Langdahl BL; Jørgensen PH; Petersen KK; Søballe K; Stilling M
Orthop Traumatol Surg Res; 2019 Sep; 105(5):1013-1020. PubMed ID: 31255502
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]