These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

102 related articles for article (PubMed ID: 22277815)

  • 1. [Reconstruction of coronary 64-multidetector-row computed tomography angiography in patients with atrial fibrillation: delete short RR intervals using electorocardiogram].
    Matsutani H; Sano T; Kondo T; Fujimoto S; Sekine T; Arai T; Morita H; Takase S
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2012; 68(1):50-8. PubMed ID: 22277815
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Relationship between heart rate and optimal reconstruction phase in coronary CT angiography performed on a 256-slice multidetector CT.
    Yang CC; Law WY; Lu KM; Wu TH
    Br J Radiol; 2019 Sep; 92(1101):20180945. PubMed ID: 31322906
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Estimation of radiation dose and image quality of coronary 320-row area detector CT angiography by optimal prospective ECG-gated protocols for different heart rate].
    Sano T; Matsutani H; Kondo T; Fujimoto S; Sekine T; Arai T; Morita H; Takase S
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2011; 67(11):1398-407. PubMed ID: 22104231
    [TBL] [Abstract][Full Text] [Related]  

  • 4. ECG-edited middiastolic phase reconstruction improves image quality at 64-MDCT coronary angiography of patients with atrial fibrillation.
    Matsumoto H; Kondo T; Watanabe S; Kikumoto R; Shimada T; Hiraoka Y; Ueda K
    AJR Am J Roentgenol; 2008 Dec; 191(6):1659-66. PubMed ID: 19020233
    [TBL] [Abstract][Full Text] [Related]  

  • 5. 256-Slice coronary computed tomographic angiography in patients with atrial fibrillation: optimal reconstruction phase and image quality.
    Oda S; Honda K; Yoshimura A; Katahira K; Noda K; Oshima S; Yuki H; Kidoh M; Utsunomiya D; Nakaura T; Namimoto T; Yamashita Y
    Eur Radiol; 2016 Jan; 26(1):55-63. PubMed ID: 25994199
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Noninvasive imaging of the coronary arteries using a 64-row multidetector CT scanner: initial clinical experience and radiation dose concerns.
    Francone M; Napoli A; Carbone I; Cavacece M; Nardis PG; Lanciotti K; Visconti S; Bertoletti L; Di Castro E; Catalano C; Passariello R
    Radiol Med; 2007 Feb; 112(1):31-46. PubMed ID: 17310293
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Radiation Dose Levels of Retrospectively ECG-Gated Coronary CT Angiography Using 70-kVp Tube Voltage in Patients with High or Irregular Heart Rates.
    Meyer M; Haubenreisser H; Schoepf UJ; Vliegenthart R; Ong MM; Doesch C; Sudarski S; Borggrefe M; Schoenberg SO; Henzler T
    Acad Radiol; 2017 Jan; 24(1):30-37. PubMed ID: 28029558
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Significance of PQ interval in acquisition of coronary multidetector row computed tomography.
    Sano T; Kondo T; Matsutani H; Morita H; Arai T; Sekine T; Takase S; Oida A; Fukazawa H; Kodama T; Kondo M; Orihara T; Yamada N; Narula J
    J Cardiol; 2009 Dec; 54(3):441-51. PubMed ID: 19944320
    [TBL] [Abstract][Full Text] [Related]  

  • 9. ECG-edit function in multidetector-row computed tomography coronary arteriography for patients with arrhythmias.
    Matsutani H; Sano T; Kondo T; Morita H; Arai T; Sekine T; Takase S; Oida A; Fukazawa H; Suguta M; Kondo M; Kodama T; Orihara T; Yamada N; Tsuyuki M; Narula J
    Circ J; 2008 Jul; 72(7):1071-8. PubMed ID: 18577814
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Prospectively ECG-Triggered Sequential Dual-Source Coronary CT Angiography in Patients with Atrial Fibrillation: Influence of Heart Rate on Image Quality and Evaluation of Diagnostic Accuracy.
    Yang L; Xu L; Schoepf UJ; Wichmann JL; Fox MA; Yan J; Fan Z; Zhang Z
    PLoS One; 2015; 10(7):e0134194. PubMed ID: 26221952
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Automatic selection of optimal cardiac-phase in coronary CT angiography--its clinical usefulness for patients with atrial fibrillation].
    Matsumoto R; Narita H; Anno H; Ida Y; Sanda Y; Katada K; Motoyama S; Sarai M; Tsuyuki M
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2008 Apr; 64(4):442-9. PubMed ID: 18451601
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Evaluation of 320-row area detector computed tomography (ADCT) coronary angiography for patients with atrial fibrillation].
    Takagi M; Kaneko T; Kato R; Anno H; Yoshimi S; Ida Y; Sanda Y; Katada K
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2011; 67(4):321-7. PubMed ID: 21532241
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The feasibility of sub-millisievert coronary CT angiography with low tube voltage, prospective ECG gating, and a knowledge-based iterative model reconstruction algorithm.
    Park CH; Lee J; Oh C; Han KH; Kim TH
    Int J Cardiovasc Imaging; 2015 Dec; 31 Suppl 2():197-203. PubMed ID: 26521066
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Coronary Computed Tomography Angiography for Patients with Atrial Fibrillation: Feasibility of Prospective Electrocardiography-gated Diastolic Acquisition with a Manual Exposure-termination Technique].
    Matsutani H; Amanuma M; Sano T; Takayanagi T; Ishizaka K; Sekine T; Arai T; Morita H
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2018; 74(2):140-147. PubMed ID: 29459540
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Multidetector-row computed tomography coronary angiography: optimization of image reconstruction phase according to the heart rate.
    Nagatani Y; Takahashi M; Takazakura R; Nitta N; Murata K; Ushio N; Matsuo S; Yamamoto T; Horie M
    Circ J; 2007 Jan; 71(1):112-21. PubMed ID: 17186988
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Knowledge-based iterative model reconstruction in coronary computed tomography angiography: comparison with hybrid iterative reconstruction and filtered back projection.
    Cha MJ; Seo JS; Yoo DS; Chong S
    Acta Radiol; 2018 Mar; 59(3):280-286. PubMed ID: 28648124
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Applicability of ECG-gated multislice helical ct to patients with atrial fibrillation.
    Sato T; Anno H; Kondo T; Harigaya H; Inoue K; Kakizawa S; Ohshima K; Sarai M; Hishida H; Katada K; Kanou M
    Circ J; 2005 Sep; 69(9):1068-73. PubMed ID: 16127188
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Submillisievert coronary CT angiography with adaptive prospective ECG-triggered sequence acquisition and iterative reconstruction in patients with high heart rate on the dual-source CT.
    Tang PH; Du BJ; Fang XM; Hu XY; Qian PY; Gao QS
    J Xray Sci Technol; 2016 Nov; 24(6):807-820. PubMed ID: 27612046
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [CT coronary angiography in patients with atrial fibrillation].
    Kovacs A; Probst C; Sommer T; Leiss A; Nähle P; Welz A; Schild H; Flacke S
    Rofo; 2005 Dec; 177(12):1655-62. PubMed ID: 16333788
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Applications of retrospective electrocardiogram editing in dual-source computed tomography coronary angiography in patients with arrhythmia].
    Shen YF; Yin L; Zheng XM; Ma MB; Wu XL; Su JW; Zheng TH; Lin LX; DU RB
    Zhongguo Yi Xue Ke Xue Yuan Xue Bao; 2010 Dec; 32(6):671-6. PubMed ID: 21219799
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.