These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

116 related articles for article (PubMed ID: 22280797)

  • 1. Pacemaker-mediated tachycardia initiated by an atrioventricular search algorithm to minimize right ventricular pacing.
    Barold SS; Stroobandt RX
    J Electrocardiol; 2012; 45(3):336-9. PubMed ID: 22280797
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A 2:1 AV rhythm: an adverse effect of a long AV delay during DDI pacing and its prevention by the ventricular intrinsic preference algorithm in DDD mode.
    Minamiguchi H; Oginosawa Y; Kohno R; Tamura M; Takeuchi M; Otsuji Y; Abe H
    Pacing Clin Electrophysiol; 2012 Jul; 35(7):e189-92. PubMed ID: 21671954
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Pacemaker-mediated tachycardia with varying cycle length: what is the mechanism?
    Verrijcken A; Huybrechts W; Willems R
    Europace; 2009 Oct; 11(10):1400-2. PubMed ID: 19578056
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Possible role of a common pacing algorithm in initiation of ventricular arrhythmia.
    Pavri BB
    Pacing Clin Electrophysiol; 2009 May; 32(5):663-6. PubMed ID: 19422590
    [No Abstract]   [Full Text] [Related]  

  • 5. ICD proarrhythmia as a consequence of an interaction with an algorithm to prevent atrial arrhythmias.
    Martínez-Sánchez J; García-Alberola A; Sánchez-Muñoz JJ; Peñafiel-Verdú P; Giner-Caro JA; Valdés-Chávarri M
    Pacing Clin Electrophysiol; 2009 Aug; 32(8):1096-8. PubMed ID: 19659632
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Initiation of ventricular tachycardia by interruption of pacemaker-mediated tachycardia in a patient with a dual-chamber implantable cardioverter defibrillator.
    Van Gelder BM; Meijer A; Dekker LR; Bracke FA
    Pacing Clin Electrophysiol; 2009 Sep; 32(9):1227-30. PubMed ID: 19719503
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Hazards of antitachycardia pacing to treat ventricular tachycardias with implantable cardioverter defibrillators.
    Maass AH; Van Gelder IC
    Europace; 2009 Jun; 11(6):819. PubMed ID: 19357140
    [No Abstract]   [Full Text] [Related]  

  • 8. Reduction of RV pacing by continuous optimization of the AV interval.
    Milasinovic G; Sperzel J; Smith TW; Mead H; Brandt J; Haisty WK; Bailey JR; Roelke M; Simonson J; Gerritse B; Englund J; Compton SJ;
    Pacing Clin Electrophysiol; 2006 Apr; 29(4):406-12. PubMed ID: 16650270
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Minimizing right ventricular pacing in pacemaker patients with intact and compromised atrioventricular conduction : Results from the EVITA Trial.
    Bauer A; Vermeulen J; Toivonen L; Voitk J; Barr C; Peytchev P
    Herzschrittmacherther Elektrophysiol; 2015 Dec; 26(4):359-66. PubMed ID: 26315154
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy of the pacemaker-mediated tachycardia algorithm in Boston Scientific devices.
    Strik M; Frontera A; Eschalier R; Defaye P; Mondoly P; Ritter P; Haïssaguerre M; Ploux S; Bordachar P
    J Electrocardiol; 2016; 49(4):522-9. PubMed ID: 27199031
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Incidence and significance of far-field R wave sensing in a VDD-implantable cardioverter defibrillator.
    Eberhardt F; Schuchert A; Schmitz D; Zerm T; Mitzenheim S; Wiegand UKh;
    Pacing Clin Electrophysiol; 2007 Mar; 30(3):395-403. PubMed ID: 17367360
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Reduction of right ventricular pacing with advanced atrioventricular search hysteresis: results of the PREVENT study.
    Kolb C; Schmidt R; Dietl JU; Weyerbrock S; Morgenstern M; Fleckenstein M; Beier T; Von Bary C; Mackes KG; Widmaier J; Kreuzer J; Semmler V; Zrenner B;
    Pacing Clin Electrophysiol; 2011 Aug; 34(8):975-83. PubMed ID: 21438891
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Beneficial effect of Bradycardia Tachycardia Response (BTR) algorithm on VT detection in the presence of rate smoothing.
    Nikolidakis S; Luria D; Weisemberg JS; Tanami N; Lev DB; Gurevitz O; Sham'a RA; Eldar M; Friedman P; Glikson M
    Pacing Clin Electrophysiol; 2012 May; 35(5):586-91. PubMed ID: 22360747
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Performance of a ventricular automatic-capture algorithm in a wide clinical setting.
    Pecora D; Morandi F; Liccardo M; Pepi P; Orazi S; Caico SI; Scaccia A; Bizeau O; Citerne O; Raciti G; Del Giudice G
    Pacing Clin Electrophysiol; 2008 Dec; 31(12):1546-53. PubMed ID: 19067806
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Performance of a specific algorithm to minimize right ventricular pacing: A multicenter study.
    Strik M; Defaye P; Eschalier R; Mondoly P; Frontera A; Ritter P; Haïssaguerre M; Ploux S; Ellenbogen KA; Bordachar P
    Heart Rhythm; 2016 Jun; 13(6):1266-73. PubMed ID: 26899544
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Repetitive non-reentrant VA synchrony and pacemaker-mediated tachycardia induced by the AF suppression algorithm.
    Kohno R; Abe H; Nagatomo T; Otsuji Y
    Pacing Clin Electrophysiol; 2009 Oct; 32(10):1333-5. PubMed ID: 19732366
    [No Abstract]   [Full Text] [Related]  

  • 17. Orthodromic pacemaker-mediated tachycardia in a biventricular system without an atrial electrode.
    Berruezo A; Mont L; Scalise A; Brugada J
    J Cardiovasc Electrophysiol; 2004 Sep; 15(9):1100-2. PubMed ID: 15363087
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Severe atrioventricular decoupling, uncoupling, and ventriculoatrial coupling during enhanced atrial pacing: incidence, mechanisms, and implications for minimizing right ventricular pacing in ICD patients.
    Sweeney MO; Ellenbogen KA; Tang AS; Johnson J; Belk P; Sheldon T
    J Cardiovasc Electrophysiol; 2008 Nov; 19(11):1175-80. PubMed ID: 18554192
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Right ventricular pacing is an independent predictor for ventricular tachycardia/ventricular fibrillation occurrence and heart failure events in patients with an implantable cardioverter-defibrillator.
    Gardiwal A; Yu H; Oswald H; Luesebrink U; Ludwig A; Pichlmaier AM; Drexler H; Klein G
    Europace; 2008 Mar; 10(3):358-63. PubMed ID: 18308756
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Tachycardia after pacemaker implantation in a patient with complete atrioventricular block.
    Duray GZ; Israel CW; Wegener FT; Hohnloser SH
    Europace; 2007 Oct; 9(10):900-3. PubMed ID: 17526508
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.