These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
115 related articles for article (PubMed ID: 22281376)
1. Can we shorten the small-bowel capsule reading time with the "Quick-view" image detection system? Saurin JC; Lapalus MG; Cholet F; D'Halluin PN; Filoche B; Gaudric M; Sacher-Huvelin S; Savalle C; Frederic M; Lamarre PA; Ben Soussan E; Dig Liver Dis; 2012 Jun; 44(6):477-81. PubMed ID: 22281376 [TBL] [Abstract][Full Text] [Related]
2. Prospective randomized comparison between axial- and lateral-viewing capsule endoscopy systems in patients with obscure digestive bleeding. Pioche M; Vanbiervliet G; Jacob P; Duburque C; Gincul R; Filoche B; Daudet J; Filippi J; Saurin JC; Endoscopy; 2014 Jun; 46(6):479-84. PubMed ID: 24285122 [TBL] [Abstract][Full Text] [Related]
3. Analysis of small-bowel capsule endoscopy reading by using Quickview mode: training assistants for reading may produce a high diagnostic yield and save time for physicians. Shiotani A; Honda K; Kawakami M; Kimura Y; Yamanaka Y; Fujita M; Matsumoto H; Tarumi K; Manabe N; Haruma K J Clin Gastroenterol; 2012; 46(10):e92-5. PubMed ID: 22495816 [TBL] [Abstract][Full Text] [Related]
4. Usefulness of flexible spectral imaging color enhancement (FICE) for the detection of angiodysplasia in the preview of capsule endoscopy. Nakamura M; Ohmiya N; Miyahara R; Ando T; Watanabe O; Kawashima H; Itoh A; Hirooka Y; Goto H Hepatogastroenterology; 2012; 59(117):1474-7. PubMed ID: 22683964 [TBL] [Abstract][Full Text] [Related]
5. Evaluations of capsule endoscopy software in reducing the reading time and the rate of false negatives by inexperienced endoscopists. Hosoe N; Rey JF; Imaeda H; Bessho R; Ichikawa R; Ida Y; Naganuma M; Kanai T; Hibi T; Ogata H Clin Res Hepatol Gastroenterol; 2012 Feb; 36(1):66-71. PubMed ID: 22074640 [TBL] [Abstract][Full Text] [Related]
6. Capsule endoscopy interpretation by an endoscopy nurse - a comparative trial. Riphaus A; Richter S; Vonderach M; Wehrmann T Z Gastroenterol; 2009 Mar; 47(3):273-6. PubMed ID: 19280540 [TBL] [Abstract][Full Text] [Related]
7. Sensitivity and specificity of the suspected blood identification system in video capsule enteroscopy. Signorelli C; Villa F; Rondonotti E; Abbiati C; Beccari G; de Franchis R Endoscopy; 2005 Dec; 37(12):1170-3. PubMed ID: 16329012 [TBL] [Abstract][Full Text] [Related]
8. Evaluation of four time-saving methods of reading capsule endoscopy videos. Kyriakos N; Karagiannis S; Galanis P; Liatsos C; Zouboulis-Vafiadis I; Georgiou E; Mavrogiannis C Eur J Gastroenterol Hepatol; 2012 Nov; 24(11):1276-80. PubMed ID: 22825645 [TBL] [Abstract][Full Text] [Related]
9. Achieving complete small-bowel capsule endoscopy: is it possible and does it matter? Schnoll-Sussman F Gastrointest Endosc; 2010 Jul; 72(1):109-11. PubMed ID: 20620277 [No Abstract] [Full Text] [Related]
10. The role of capsule endoscopy combined with double-balloon enteroscopy in diagnosis of small bowel diseases. Li XB; Ge ZZ; Dai J; Gao YJ; Liu WZ; Hu YB; Xiao SD Chin Med J (Engl); 2007 Jan; 120(1):30-5. PubMed ID: 17254484 [TBL] [Abstract][Full Text] [Related]
11. Prospective, randomized comparison of two small-bowel capsule endoscopy systems in patients with obscure GI bleeding. Pioche M; Gaudin JL; Filoche B; Jacob P; Lamouliatte H; Lapalus MG; Duburque C; Chaput U; Ben Soussan E; Daudet J; Tournan R; Gaudric M; Edery J; Cellier C; Halluin PN; Saurin JC; Gastrointest Endosc; 2011 Jun; 73(6):1181-8. PubMed ID: 21628014 [TBL] [Abstract][Full Text] [Related]
13. The evaluation of the OMOM capsule endoscopy with similar pictures elimination mode. Xu Y; Zhang W; Ye S; Han Z; Bai Y; Li A; Chen Z; Wan T; Liu S Clin Res Hepatol Gastroenterol; 2014 Dec; 38(6):757-62. PubMed ID: 25282556 [TBL] [Abstract][Full Text] [Related]
14. [Capsule endoscopy for the diagnosis of small bowel diseases. An updated statement by the endoscopy section of DGVS]. May A; Albert J; Keuchel M; Moog G; Hartmann D Z Gastroenterol; 2010 Dec; 48(12):1384-404. PubMed ID: 21108180 [No Abstract] [Full Text] [Related]
15. Comparison of two commercial systems for computer-assisted detection (CAD) as an aid to interpreting screening mammograms. Ciatto S; Ambrogetti D; Bonardi R; Brancato B; Catarzi S; Risso G; Rosselli Del Turco M Radiol Med; 2004; 107(5-6):480-8. PubMed ID: 15195010 [TBL] [Abstract][Full Text] [Related]
16. Image-enhanced capsule endoscopy based on the diagnosis of vascularity when using a new type of capsule. Aihara H; Ikeda K; Tajiri H Gastrointest Endosc; 2011 Jun; 73(6):1274-9. PubMed ID: 21492852 [TBL] [Abstract][Full Text] [Related]
17. Capsule endoscopy and bowel preparation with oral sodium phosphate: a prospective randomized controlled trial. Lapalus MG; Ben Soussan E; Saurin JC; Favre O; D'Halluin PN; Coumaros D; Gaudric M; Fumex F; Antonietti M; Gaudin JL; Jacob P; Heresbach D; Pilichos C; Fan R; Mozer M; Heyries L; Dumortier J; Ponchon T; Gastrointest Endosc; 2008 Jun; 67(7):1091-6. PubMed ID: 18513551 [TBL] [Abstract][Full Text] [Related]
18. Clinical outcome of patients examined by capsule endoscopy for suspected small bowel Crohn's disease. Girelli CM; Porta P; Malacrida V; Barzaghi F; Rocca F Dig Liver Dis; 2007 Feb; 39(2):148-54. PubMed ID: 17196893 [TBL] [Abstract][Full Text] [Related]
19. High diagnostic and clinical impact of small-bowel capsule endoscopy in patients with hereditary hemorrhagic telangiectasia with overt digestive bleeding and/or severe anemia. Grève E; Moussata D; Gaudin JL; Lapalus MG; Giraud S; Dupuis-Girod S; Calender A; Plauchu H; Saurin JC Gastrointest Endosc; 2010 Apr; 71(4):760-7. PubMed ID: 20170910 [TBL] [Abstract][Full Text] [Related]