BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

241 related articles for article (PubMed ID: 22288931)

  • 1. Comparison of malleable stylet and reusable and disposable bougies by paramedics in a simulated difficult intubation.
    Gregory P; Woollard M; Lighton D; Munro G; Jenkinson E; Newcombe RG; O'Meara P; Hamilton L
    Anaesthesia; 2012 Apr; 67(4):371-6. PubMed ID: 22288931
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A comparison of a fiberoptic stylet and a bougie as adjuncts to direct laryngoscopy in a manikin-simulated difficult airway.
    Kovacs G; Law JA; McCrossin C; Vu M; Leblanc D; Gao J
    Ann Emerg Med; 2007 Dec; 50(6):676-85. PubMed ID: 17681639
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Bougies as an aid for endotracheal intubation with the Airway Scope: bench and manikin comparison studies.
    Takenaka I; Aoyama K; Iwagaki T; Takenaka Y
    BMC Anesthesiol; 2017 Oct; 17(1):133. PubMed ID: 28969598
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The effect of temperature on bougies: a photographic and manikin study.
    Mingo O; Suaris P; Charman S; Ferguson C; Patel A
    Anaesthesia; 2008 Oct; 63(10):1135-8. PubMed ID: 18717662
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A comparison of the Seeing Optical Stylet and the gum elastic bougie in simulated difficult tracheal intubation: a manikin study.
    Evans A; Morris S; Petterson J; Hall JE
    Anaesthesia; 2006 May; 61(5):478-81. PubMed ID: 16674624
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Comparison of bougie-assisted intubation with traditional endotracheal intubation in a simulated difficult airway.
    Messa MJ; Kupas DF; Dunham DL
    Prehosp Emerg Care; 2011; 15(1):30-3. PubMed ID: 21067319
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of a disposable bougie versus a newly designed malleable bougie in the intubation of a difficult manikin airway.
    Boedeker BH; Bernhagen M; Miller DJ; Murray WB
    Stud Health Technol Inform; 2011; 163():65-7. PubMed ID: 21335760
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of tracheal tube introducers in simulated difficult intubation.
    Janakiraman C; Hodzovic I; Reddy S; Desai N; Wilkes AR; Latto IP
    Anaesthesia; 2009 Mar; 64(3):309-14. PubMed ID: 19302646
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A comparison of simulated difficult intubation with multiple-use and single-use bougies in a manikin.
    Annamaneni R; Hodzovic I; Wilkes AR; Latto IP
    Anaesthesia; 2003 Jan; 58(1):45-9. PubMed ID: 12492669
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Evaluation of Frova, single-use intubation introducer, in a manikin. Comparison with Eschmann multiple-use introducer and Portex single-use introducer.
    Hodzovic I; Latto IP; Wilkes AR; Hall JE; Mapleson WW
    Anaesthesia; 2004 Aug; 59(8):811-6. PubMed ID: 15270974
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of the Airway Scope, gum elastic bougie and fibreoptic bronchoscope in simulated difficult tracheal intubation: a manikin study.
    Koyama Y; Inagawa G; Miyashita T; Kikuchi T; Miura N; Miki T; Kurihara R; Kamiya Y; Goto T
    Anaesthesia; 2007 Sep; 62(9):936-9. PubMed ID: 17697222
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of the Levitan FPS Scope and the single-use bougie for simulated difficult intubation in anaesthetised patients.
    Greenland KB; Liu G; Tan H; Edwards M; Irwin MG
    Anaesthesia; 2007 May; 62(5):509-15. PubMed ID: 17448065
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Bougie-assisted difficult airway management in a manikin - the effect of position held on placement and force exerted by the tip.
    Hodzovic I; Wilkes AR; Latto IP
    Anaesthesia; 2004 Jan; 59(1):38-43. PubMed ID: 14687097
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Tracheal intubation through the intubating laryngeal mask airway training on manikin: comparison of single use and reusable devices from the same manufacturer].
    Haardt V; Lenfant F; Cailliod R; Freysz M
    Ann Fr Anesth Reanim; 2008 Apr; 27(4):297-301. PubMed ID: 18375094
    [TBL] [Abstract][Full Text] [Related]  

  • 15. To shape or not to shape...simulated bougie-assisted difficult intubation in a manikin.
    Hodzovic I; Wilkes AR; Latto IP
    Anaesthesia; 2003 Aug; 58(8):792-7. PubMed ID: 12859474
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A comparison of plastic single-use with metallic reusable laryngoscope blades for out-of-hospital tracheal intubation.
    Jabre P; Leroux B; Brohon S; Penet C; Lockey D; Adnet F; Margenet A; Marty J; Combes X
    Ann Emerg Med; 2007 Sep; 50(3):258-63. PubMed ID: 17583382
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of six different intubation aids for use while wearing CBRN-PPE: a manikin study.
    Castle N; Pillay Y; Spencer N
    Resuscitation; 2011 Dec; 82(12):1548-52. PubMed ID: 21763057
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Bougie-related airway trauma: dangers of the hold-up sign.
    Marson BA; Anderson E; Wilkes AR; Hodzovic I
    Anaesthesia; 2014 Mar; 69(3):219-23. PubMed ID: 24548354
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of intubation performance by emergency medicine residents using gum elastic bougie versus standard stylet in simulated easy and difficult intubation scenarios.
    Walsh R; Cookman L; Luerssen E
    Emerg Med Australas; 2014 Oct; 26(5):446-9. PubMed ID: 25158992
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Airtraq vs standard laryngoscopy by student paramedics and experienced prehospital laryngoscopists managing a model of difficult intubation.
    Woollard M; Lighton D; Mannion W; Watt J; McCrea C; Johns I; Hamilton L; O'Meara P; Cotton C; Smyth M
    Anaesthesia; 2008 Jan; 63(1):26-31. PubMed ID: 18086067
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.