These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

74 related articles for article (PubMed ID: 22292157)

  • 1. Tears of joy for noninvasive glucose test.
    Sutton C
    Bioanalysis; 2011 Dec; 3(24):2706. PubMed ID: 22292157
    [No Abstract]   [Full Text] [Related]  

  • 2. Measurement of tear glucose levels with amperometric glucose biosensor/capillary tube configuration.
    Yan Q; Peng B; Su G; Cohan BE; Major TC; Meyerhoff ME
    Anal Chem; 2011 Nov; 83(21):8341-6. PubMed ID: 21961809
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Glucose biosensor based on immobilization of glucose oxidase in platinum nanoparticles/graphene/chitosan nanocomposite film.
    Wu H; Wang J; Kang X; Wang C; Wang D; Liu J; Aksay IA; Lin Y
    Talanta; 2009 Nov; 80(1):403-6. PubMed ID: 19782243
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A novel glucose biosensor based on immobilization of glucose oxidase in chitosan on a glassy carbon electrode modified with gold-platinum alloy nanoparticles/multiwall carbon nanotubes.
    Kang X; Mai Z; Zou X; Cai P; Mo J
    Anal Biochem; 2007 Oct; 369(1):71-9. PubMed ID: 17678866
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Characterization of natural chitosan membranes from the carapace of the soldier crab Mictyris brevidactylus and its application to immobilize glucose oxidase in amperometric flow-injection biosensing system.
    Chen PC; Hsieh BC; Chen RL; Wang TY; Hsiao HY; Cheng TJ
    Bioelectrochemistry; 2006 Jan; 68(1):72-80. PubMed ID: 15950546
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Preparation, characterization, and application of an enzyme-immobilized magnetic microreactor for flow injection analysis.
    Nomura A; Shin S; Mehdi OO; Kauffmann JM
    Anal Chem; 2004 Sep; 76(18):5498-502. PubMed ID: 15362912
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Glucose oxidase multilayer modified microcantilevers for glucose measurement.
    Yan X; Xu XK; Ji HF
    Anal Chem; 2005 Oct; 77(19):6197-204. PubMed ID: 16194079
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [X-ray microanalysis of the activity of immobilized glucose oxidase on enzyme electrode].
    Li T; Yao ZH; Qui MD; AN W; Shi DG
    Guang Pu Xue Yu Guang Pu Fen Xi; 2005 Jul; 25(7):1151-4. PubMed ID: 16241079
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Catalase-conjugated liposomes encapsulating glucose oxidase for controlled oxidation of glucose with decomposition of hydrogen peroxide produced.
    Yoshimoto M; Takaki N; Yamasaki M
    Colloids Surf B Biointerfaces; 2010 Sep; 79(2):403-8. PubMed ID: 20537512
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Immobilization of lignin peroxidase on nanoporous gold: enzymatic properties and in situ release of H2O2 by co-immobilized glucose oxidase.
    Qiu H; Li Y; Ji G; Zhou G; Huang X; Qu Y; Gao P
    Bioresour Technol; 2009 Sep; 100(17):3837-42. PubMed ID: 19349165
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The influence of peroxide-stabilizing agents on enzyme deactivation by H2O2.
    Cho YK; Bailey JE
    Biotechnol Bioeng; 1977 Jan; 19(1):157-8. PubMed ID: 843614
    [No Abstract]   [Full Text] [Related]  

  • 12. Analysis of the coupled transport, reaction, and deactivation phenomena in the immobilized glucose oxidase and catalase system.
    Reuss M; Buchholz K
    Biotechnol Bioeng; 1979 Nov; 21(11):2061-81. PubMed ID: 486720
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Various applications of immobilized glucose oxidase and polyphenol oxidase in a conducting polymer matrix.
    Cil M; Böyükbayram AE; Kiralp S; Toppare L; Yağci Y
    Int J Biol Macromol; 2007 Jun; 41(1):49-55. PubMed ID: 17291580
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biosensors for diabetes mellitus.
    Pickup JC
    Biotechnology; 1989; 11():227-47. PubMed ID: 2650763
    [No Abstract]   [Full Text] [Related]  

  • 15. Applications of purification reactions for minimizing reaction-generated enzyme poisoning.
    Yeung SY; Cho Y; Bailey JE
    Biotechnol Bioeng; 1978 Aug; 20(8):1249-65. PubMed ID: 687790
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Development of an implantable D-serine biosensor for in vivo monitoring using mammalian D-amino acid oxidase on a poly (o-phenylenediamine) and Nafion-modified platinum-iridium disk electrode.
    Zain ZM; O'Neill RD; Lowry JP; Pierce KW; Tricklebank M; Dewa A; Ab Ghani S
    Biosens Bioelectron; 2010 Feb; 25(6):1454-9. PubMed ID: 19945264
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Enzyme immobilization on activated carbon: alleviation of enzyme deactivation by hydrogen peroxide.
    Cho YK; Bailey JE
    Biotechnol Bioeng; 1977 May; 19(5):769-75. PubMed ID: 403970
    [No Abstract]   [Full Text] [Related]  

  • 18. One-minute blood glucose testing.
    DeLawter DE
    Am Fam Physician; 1973 Sep; 8(3):174-5. PubMed ID: 4729715
    [No Abstract]   [Full Text] [Related]  

  • 19. Effects of omega-3 fatty acids on apoptosis of human gastric epithelial cells exposed to silica-immobilized glucose oxidase.
    Yu JH; Kang SG; Jung UY; Jun CH; Kim H
    Ann N Y Acad Sci; 2009 Aug; 1171():359-64. PubMed ID: 19723076
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Estimation of tear glucose level and its role as a prompt indicator of blood sugar level.
    Chatterjee PR; De S; Datta H; Chatterjee S; Biswas MC; Sarkar K; Mandal LK
    J Indian Med Assoc; 2003 Aug; 101(8):481-3. PubMed ID: 15071801
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.