BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

324 related articles for article (PubMed ID: 22292204)

  • 1. The tribological behaviour of different clearance MOM hip joints with lubricants of physiological viscosities.
    Hu XQ; Wood RJ; Taylor A; Tuke MA
    Proc Inst Mech Eng H; 2011 Nov; 225(11):1061-9. PubMed ID: 22292204
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The effects of proteins on the friction and lubrication of artificial joints.
    Scholes SC; Unsworth A
    Proc Inst Mech Eng H; 2006 Aug; 220(6):687-93. PubMed ID: 16961188
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of friction and lubrication of different hip prostheses.
    Scholes SC; Unsworth A
    Proc Inst Mech Eng H; 2000; 214(1):49-57. PubMed ID: 10718050
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Modes of lubrication in human hip joints.
    Roberts BJ; Unsworth A; Mian N
    Ann Rheum Dis; 1982 Jun; 41(3):217-24. PubMed ID: 7092334
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The effect of femoral head diameter upon lubrication and wear of metal-on-metal total hip replacements.
    Smith SL; Dowson D; Goldsmith AA
    Proc Inst Mech Eng H; 2001; 215(2):161-70. PubMed ID: 11382075
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of wear of bearing surfaces on elastohydrodynamic lubrication of metal-on-metal hip implants.
    Liu F; Jin ZM; Hirt F; Rieker C; Roberts P; Grigoris P
    Proc Inst Mech Eng H; 2005 Sep; 219(5):319-28. PubMed ID: 16225148
    [TBL] [Abstract][Full Text] [Related]  

  • 7. In vitro friction and lubrication of large bearing hip prostheses.
    Flanagan S; Jones E; Birkinshaw C
    Proc Inst Mech Eng H; 2010; 224(7):853-64. PubMed ID: 20839653
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of swing phase load on metal-on-metal hip lubrication, friction and wear.
    Williams S; Jalali-Vahid D; Brockett C; Jin Z; Stone MH; Ingham E; Fisher J
    J Biomech; 2006; 39(12):2274-81. PubMed ID: 16143337
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Compliant layer acetabular cups: friction testing of a range of materials and designs for a new generation of prosthesis that mimics the natural joint.
    Scholes SC; Burgess IC; Marsden HR; Unsworth A; Jones E; Smith N
    Proc Inst Mech Eng H; 2006 Jul; 220(5):583-96. PubMed ID: 16898216
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Does surface wettability influence the friction and wear of large-diameter CoCrMo alloy hip resurfacings?
    Curran S; Hoskin T; Williams S; Scholes SC; Kinbrum A; Unsworth A
    Proc Inst Mech Eng H; 2013 Aug; 227(8):847-58. PubMed ID: 23852389
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Appropriate radial clearance of ceramic-on-ceramic total hip prostheses to realize squeeze-film lubrication.
    Mabuchi K; Sakai R; Ota M; Ujihira M
    Clin Biomech (Bristol, Avon); 2004 May; 19(4):362-9. PubMed ID: 15109756
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Viscosity determination of synovial fluids from the canine hip and elbow joint as well as the human knee joint].
    Helms G; Rittmann P; Wefstaedt P; Windhagen H; Pressel T; Behrens BA; Nolte I
    Berl Munch Tierarztl Wochenschr; 2008; 121(9-10):374-80. PubMed ID: 18822609
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Steady-state elastohydrodynamic lubrication analysis of a metal-on-metal hip implant employing a metallic cup with an ultra-high molecular weight polyethylene backing.
    Liu F; Wang FC; Jin ZM; Hirt F; Rieker C; Grigoris P
    Proc Inst Mech Eng H; 2004; 218(4):261-70. PubMed ID: 15376728
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The influence of clearance on friction, lubrication and squeaking in large diameter metal-on-metal hip replacements.
    Brockett CL; Harper P; Williams S; Isaac GH; Dwyer-Joyce RS; Jin Z; Fisher J
    J Mater Sci Mater Med; 2008 Apr; 19(4):1575-9. PubMed ID: 17990078
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Lubrication of metal-on-metal hip joints: the effect of protein content and load on film formation and wear.
    Myant C; Underwood R; Fan J; Cann PM
    J Mech Behav Biomed Mater; 2012 Feb; 6():30-40. PubMed ID: 22301171
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Metal-on-metal hip joint tribology.
    Dowson D; Jin ZM
    Proc Inst Mech Eng H; 2006 Feb; 220(2):107-18. PubMed ID: 16669380
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of wear, acetabular cup inclination angle, load and serum degradation on the friction of a large diameter metal-on-metal hip prosthesis.
    Saikko V
    Clin Biomech (Bristol, Avon); 2019 Mar; 63():1-9. PubMed ID: 30784784
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Analysis of elastohydrodynamic lubrication in McKee-Farrar metal-on-metal hip joint replacement.
    Yew A; Udofia I; Jagatia M; Jin ZM
    Proc Inst Mech Eng H; 2004; 218(1):27-34. PubMed ID: 14982343
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Synovial fluid lubrication of artificial joints: protein film formation and composition.
    Fan J; Myant C; Underwood R; Cann P
    Faraday Discuss; 2012; 156():69-85; discussion 87-103. PubMed ID: 23285623
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of bearing geometry and structure support on transient elastohydrodynamic lubrication of metal-on-metal hip implants.
    Liu F; Jin Z; Roberts P; Grigoris P
    J Biomech; 2007; 40(6):1340-9. PubMed ID: 16824529
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 17.