These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
118 related articles for article (PubMed ID: 2229253)
1. Determination of the enantiomers of mefloquine in plasma and whole blood using a coupled achiral-chiral high-performance liquid chromatographic system. Gimenez F; Farinotti R; Thuillier A; Hazebroucq G; Wainer IW J Chromatogr; 1990 Aug; 529(2):339-46. PubMed ID: 2229253 [TBL] [Abstract][Full Text] [Related]
2. Coupled column chromatography in chiral separation of salmeterol. Kim KH; Yun HW; Kim HJ; Park HJ; Choi PW Arch Pharm Res; 1998 Apr; 21(2):212-6. PubMed ID: 9875433 [TBL] [Abstract][Full Text] [Related]
3. Improved column-switching liquid chromatographic method for the determination of the enantiomers of mefloquine. Gimenez F; Dumartin C; Wainer IW; Farinotti R J Chromatogr; 1993 Sep; 619(1):161-6. PubMed ID: 8245157 [TBL] [Abstract][Full Text] [Related]
4. Determination of bevantolol enantiomers in human plasma by coupled achiral-chiral high performance-liquid chromatography. Oh JW; Trung TQ; Sin KS; Kang JS; Kim KH Chirality; 2007 Jul; 19(7):528-35. PubMed ID: 17457831 [TBL] [Abstract][Full Text] [Related]
5. Determination of terbutaline enantiomers in human plasma by coupled achiral-chiral high performance liquid chromatography. Kim KH; Kim HJ; Hong SP; Shin SD Arch Pharm Res; 2000 Oct; 23(5):441-5. PubMed ID: 11059819 [TBL] [Abstract][Full Text] [Related]
6. Determination of terbutaline enantiomers in human urine by coupled achiral-chiral high-performance liquid chromatography with fluorescence detection. Kim KH; Kim HJ; Kim JH; Shin SD J Chromatogr B Biomed Sci Appl; 2001 Feb; 751(1):69-77. PubMed ID: 11232857 [TBL] [Abstract][Full Text] [Related]
7. Determination of the enantiomers of zopiclone and its two chiral metabolites in urine using an automated coupled achiral-chiral chromatographic system. Fernandez C; Gimenez F; Baune B; Maradeix V; Thuillier A; Farinotti R J Chromatogr; 1993 Aug; 617(2):271-8. PubMed ID: 8408393 [TBL] [Abstract][Full Text] [Related]
8. Stereospecific determination of mefloquine in biological fluids by high-performance liquid chromatography. Souri E; Farsam H; Jamali F J Chromatogr B Biomed Sci Appl; 1997 Oct; 700(1-2):215-22. PubMed ID: 9390732 [TBL] [Abstract][Full Text] [Related]
9. Determination of hydroxychloroquine and its major metabolites in plasma using sequential achiral-chiral high-performance liquid chromatography. Iredale J; Wainer IW J Chromatogr; 1992 Jan; 573(2):253-8. PubMed ID: 1601957 [TBL] [Abstract][Full Text] [Related]
10. Determination of zopiclone enantiomers in plasma by liquid chromatography using a chiral cellulose carbamate column. Fernandez C; Baune B; Gimenez F; Thuillier A; Farinotti R J Chromatogr; 1991 Dec; 572(1-2):195-202. PubMed ID: 1818054 [TBL] [Abstract][Full Text] [Related]
11. Determination of metoprolol enantiomers in human urine by coupled achiral-chiral chromatography. Kim KH; Kim HJ; Kang JS; Mar W J Pharm Biomed Anal; 2000 Mar; 22(2):377-84. PubMed ID: 10719921 [TBL] [Abstract][Full Text] [Related]
12. Enantioselective high-performance liquid chromatographic determination of (SR)- and (RS)-mefloquine in plasma using N-benzyloxycarbonyl-glycyl-L-proline as chiral counter ion. Bergqvist Y; al Kabbani J; Pettersson C; Huynh NH J Chromatogr; 1993 Oct; 620(2):217-24. PubMed ID: 8300789 [TBL] [Abstract][Full Text] [Related]
13. High-performance liquid chromatographic determination of (SR)- and (RS)-enantiomers of mefloquine in plasma and capillary blood sampled on paper after derivatization with (-)-1-(9-fluorenyl)ethyl chloroformate. Bergqvist Y; Doverskog M; Kabbani JA J Chromatogr; 1994 Jan; 652(1):73-81. PubMed ID: 8014230 [TBL] [Abstract][Full Text] [Related]
14. Direct injection analysis of atenolol enantiomers in plasma using an achiral/chiral coupled column HPLC system. He J; Shibukawa A; Nakagawa T; Wada H; Fujima H; Imai E; Go-oh Y Chem Pharm Bull (Tokyo); 1993 Mar; 41(3):544-8. PubMed ID: 8477506 [TBL] [Abstract][Full Text] [Related]
15. The measurement of warfarin enantiomers in serum using coupled achiral/chiral, high-performance liquid chromatography (HPLC). Chu YQ; Wainer IW Pharm Res; 1988 Oct; 5(10):680-3. PubMed ID: 3244624 [TBL] [Abstract][Full Text] [Related]
16. Enantiomeric determination of the plasma levels of omeprazole by direct plasma injection using high-performance liquid chromatography with achiral-chiral column-switching. Cass QB; Lima VV; Oliveira RV; Cassiano NM; Degani AL; Pedrazzoli J J Chromatogr B Analyt Technol Biomed Life Sci; 2003 Dec; 798(2):275-81. PubMed ID: 14643507 [TBL] [Abstract][Full Text] [Related]
17. High-performance liquid chromatographic method for the enantioselective analysis of mefloquine in plasma and urine. Wallén L; Ericsson O; Wikström I; Hellgren U J Chromatogr B Biomed Appl; 1994 Apr; 655(1):153-7. PubMed ID: 8061825 [TBL] [Abstract][Full Text] [Related]
18. Determination of the enantiomers of verapamil and norverapamil in serum using coupled achiral-chiral high-performance liquid chromatography. Chu YQ; Wainer IW J Chromatogr; 1989 Dec; 497():191-200. PubMed ID: 2625456 [TBL] [Abstract][Full Text] [Related]
19. Determination of low levels of the stereoisomers of leucovorin and 5-methyltetrahydrofolate in plasma using a coupled chiral-achiral high-performance liquid chromatographic system with post-chiral column peak compression. Lin SL; Jadaud P; Whitfield LR; Wainer IW J Chromatogr; 1990 Nov; 532(2):227-36. PubMed ID: 2084121 [TBL] [Abstract][Full Text] [Related]
20. Improved validated assay for the determination of mefloquine and its carboxy metabolite in plasma, serum and whole blood using solid-phase extraction and high-performance liquid chromatography. Green MD; Bergqvist Y; Mount DL; Corbett S; D'Souza MJ J Chromatogr B Biomed Sci Appl; 1999 Apr; 727(1-2):159-65. PubMed ID: 10360435 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]