These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

370 related articles for article (PubMed ID: 22301391)

  • 1. The association of rate pressure product (RPP) and myocardial perfusion imaging (MPI) findings: a preliminary study.
    Ansari M; Javadi H; Pourbehi M; Mogharrabi M; Rayzan M; Semnani S; Jallalat S; Amini A; Abbaszadeh M; Barekat M; Nabipour I; Assadi M
    Perfusion; 2012 May; 27(3):207-13. PubMed ID: 22301391
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Relationship between gated myocardial perfusion SPECT findings and hemodynamic, electrocardiographic, and heart rate changes after Dipyridamole infusion.
    Gholoobi A; Ayati N; Baghyari A; Mouhebati M; Atar B; Dabbagh Kakhki VR
    Int J Cardiovasc Imaging; 2017 Jun; 33(6):951-956. PubMed ID: 28150082
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Association of hemodynamic response during dipyridamole stress testing with 99mTc-MIBI SPET myocardial perfusion image findings.
    Hatutale A; Vorster M; Ankrah AO; Rheeder P; Sathekge MM
    Hell J Nucl Med; 2013; 16(3):181-5. PubMed ID: 24137582
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Assessment of absolute Tc-99m tetrofosmin retention in the myocardium as an index of myocardial blood flow and coronary flow reserve by gated-SPECT/CT: a feasibility study.
    Apostolopoulos DJ; Kaspiri A; Spyridonidis T; Patsouras N; Savvopoulos CA; Davlouros P; Vassilakos PJ; Alexopoulos D
    Ann Nucl Med; 2015 Aug; 29(7):588-602. PubMed ID: 25971450
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Incremental Diagnostic Performance of Combined Parameters in the Detection of Severe Coronary Artery Disease Using Exercise Gated Myocardial Perfusion Imaging.
    Liu CJ; Wu YW; Ko KY; Chen YC; Cheng MF; Yen RF; Tzen KY
    PLoS One; 2015; 10(7):e0134485. PubMed ID: 26230651
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Ventricular-arterial coupling assessment using gated single-photon emission computed tomography: relationship with reserve pulse pressure and repolarization abnormalities.
    Masoli OH; Redruello M; San Miguel L; Medus J; Pabstleben N; Blanco JM; Collaud C
    Nucl Med Commun; 2016 Dec; 37(12):1297-1301. PubMed ID: 27454405
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparative utility of gated myocardial perfusion imaging and transthoracic coronary flow reserve for the assessment of coronary artery disease in patients with left bundle branch block.
    Pavlovic S; Sobic-Saranovic D; Djordjevic-Dikic A; Beleslin B; Stepanovic J; Artiko V; Giga V; Petrasinovic Z; Ostojic M; Vujisic-Tesic B; Obradovic V
    Nucl Med Commun; 2010 Apr; 31(4):334-40. PubMed ID: 20042989
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Prediction of new-onset refractory congestive heart failure using gated myocardial perfusion SPECT imaging in patients with known or suspected coronary artery disease subanalysis of the J-ACCESS database.
    Nakata T; Hashimoto A; Wakabayashi T; Kusuoka H; Nishimura T
    JACC Cardiovasc Imaging; 2009 Dec; 2(12):1393-400. PubMed ID: 20083074
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Reduced heart rate response to dipyridamole in patients undergoing myocardial perfusion SPECT.
    Gorur GD; Ciftci EA; Kozdag G; Isgoren S; Oc MA; Haksal C; Gur M; Demir H
    Ann Nucl Med; 2012 Oct; 26(8):609-15. PubMed ID: 22714113
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Gated-SPECT myocardial perfusion imaging and coronary calcium score for evaluation of patients with acute chest pain and a normal or nondiagnostic electrocardiogram.
    Peix A; Batista E; Cabrera LO; Rodríguez L; Padrón K; Saínz B; Mendoza V; Carrillo R; Fernández Y; Mena E; Dondi M
    Coron Artery Dis; 2012 Nov; 23(7):438-44. PubMed ID: 22868413
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The additive value of transient left ventricular dilation using two-day dipyridamole 99mTc-MIBI SPET for screening coronary artery disease in patients with otherwise normal myocardial perfusion: a comparison between diabetic and non-diabetic cases.
    Fallahi B; Beiki D; Fard-Esfahani A; Akbarpour S; Abolhassani A; Kakhki VR; Eftekhari M
    Hell J Nucl Med; 2010; 13(3):246-52. PubMed ID: 21193879
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of patients with coronary artery disease. IQ-SPECT protocol in myocardial perfusion imaging: Preliminary results.
    Caobelli F; Pizzocaro C; Paghera B; Guerra UP
    Nuklearmedizin; 2013; 52(5):178-85. PubMed ID: 23703588
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Influence of attenuation correction on transient left ventricular dilation in dual isotope myocardial perfusion imaging in patients with known or suspected coronary artery disease.
    Brodov Y; Frenkel A; Chouraqui P; Przewloka K; Rispler S; Abadi S; Keidar Z
    Am J Cardiol; 2012 Jul; 110(1):57-61. PubMed ID: 22481016
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Stress and rest dynamic myocardial perfusion imaging by evaluation of complete time-attenuation curves with dual-source CT.
    Ho KT; Chua KC; Klotz E; Panknin C
    JACC Cardiovasc Imaging; 2010 Aug; 3(8):811-20. PubMed ID: 20705260
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Incremental value of regional wall motion abnormalities for detecting obstructive coronary artery disease by rest-only electrocardiogram-gated single-photon emission computerized tomography myocardial perfusion imaging in suspected coronary artery disease patients.
    Liu B; Yu W; Wang J; Shao X; Zhang F; Yang M; Yang X; Wu Z; Li S; Shi Y; Wang B; Xu Y; Wang Y
    Nucl Med Commun; 2021 Mar; 42(3):276-283. PubMed ID: 33252509
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Coronary arteriography in the diagnosis results and prognosis analysis of suspected coronary artery disease in patients with normal SPET myocardial perfusion imaging.
    Yuan JW; Wang YT; Lu CZ
    Hell J Nucl Med; 2015; 18(3):215-21. PubMed ID: 26637500
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The clinical usefulness of phase analysis in detecting coronary artery disease using dipyridamole thallium-201-gated myocardial perfusion imaging with a cadmium-zinc-telluride camera.
    Lin WL; Wang SY; Shiau YC; Wu YW
    J Nucl Cardiol; 2020 Feb; 27(1):241-250. PubMed ID: 30171522
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Physiological basis for angina and ST-segment change PET-verified thresholds of quantitative stress myocardial perfusion and coronary flow reserve.
    Johnson NP; Gould KL
    JACC Cardiovasc Imaging; 2011 Sep; 4(9):990-8. PubMed ID: 21920337
    [TBL] [Abstract][Full Text] [Related]  

  • 19. High-speed myocardial perfusion imaging initial clinical comparison with conventional dual detector anger camera imaging.
    Sharir T; Ben-Haim S; Merzon K; Prochorov V; Dickman D; Ben-Haim S; Berman DS
    JACC Cardiovasc Imaging; 2008 Mar; 1(2):156-63. PubMed ID: 19356422
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Diagnostic value of ischemia severity at myocardial perfusion imaging in elderly persons with suspected coronary disease.
    Canepa M; Bezante G; Vianello P; Ameri P; Milaneschi Y; Aste M; Cavalla F; Bauckneht M; Marini C; Balbi M; Brunelli C; Sambuceti G
    J Cardiovasc Med (Hagerstown); 2016 Oct; 17(10):719-28. PubMed ID: 26599683
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 19.