BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

160 related articles for article (PubMed ID: 22303587)

  • 1. Computational simulation of hematocrit effects on arterial gas embolism dynamics.
    Mukundakrishnan K; Ayyaswamy PS; Eckmann DM
    Aviat Space Environ Med; 2012 Feb; 83(2):92-101. PubMed ID: 22303587
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Bubble motion in a blood vessel: shear stress induced endothelial cell injury.
    Mukundakrishnan K; Ayyaswamy PS; Eckmann DM
    J Biomech Eng; 2009 Jul; 131(7):074516. PubMed ID: 19640152
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Finite-sized gas bubble motion in a blood vessel: non-Newtonian effects.
    Mukundakrishnan K; Ayyaswamy PS; Eckmann DM
    Phys Rev E Stat Nonlin Soft Matter Phys; 2008 Sep; 78(3 Pt 2):036303. PubMed ID: 18851139
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effect of a soluble surfactant on a finite sized bubble motion in a blood vessel.
    Swaminathan TN; Mukundakrishnan K; Ayyaswamy PS; Eckmann DM
    J Fluid Mech; 2010 Jan; 642():509-539. PubMed ID: 20305744
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Surfactant properties differentially influence intravascular gas embolism mechanics.
    Swaminathan TN; Ayyaswamy PS; Eckmann DM
    Ann Biomed Eng; 2010 Dec; 38(12):3649-63. PubMed ID: 20625830
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Direct numerical simulations of micro-bubble expansion in gas embolotherapy.
    Ye T; Bull JL
    J Biomech Eng; 2004 Dec; 126(6):745-59. PubMed ID: 15796333
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Blood viscosity in man following decompression: correlations wiht hematocrit and venous gas emboli.
    Neuman TS; Harris MG; Linaweaver PG
    Aviat Space Environ Med; 1976 Aug; 47(8):803-7. PubMed ID: 949295
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Numerical modeling of the transport to an intravascular bubble in a tube with a soluble/insoluble surfactant.
    Ayyaswamy PS; Zhang J; Eckmann DM
    Ann N Y Acad Sci; 2006 Sep; 1077():270-87. PubMed ID: 17124130
    [TBL] [Abstract][Full Text] [Related]  

  • 9. DCS or DCI? The difference and why it matters.
    Mitchell SJ
    Diving Hyperb Med; 2019 Sep; 49(3):152-153. PubMed ID: 31523788
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Mathematical model of gas bubble evolution in a straight tube.
    Halpern D; Jiang Y; Himm JF
    J Biomech Eng; 1999 Oct; 121(5):505-13. PubMed ID: 10529918
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Microbubble oscillating in a microvessel filled with viscous fluid: A finite element modeling study.
    Chen C; Gu Y; Tu J; Guo X; Zhang D
    Ultrasonics; 2016 Mar; 66():54-64. PubMed ID: 26651263
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Wall shear stress--an important determinant of endothelial cell function and structure--in the arterial system in vivo. Discrepancies with theory.
    Reneman RS; Arts T; Hoeks AP
    J Vasc Res; 2006; 43(3):251-69. PubMed ID: 16491020
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Bubble splitting in bifurcating tubes: a model study of cardiovascular gas emboli transport.
    Calderón AJ; Fowlkes JB; Bull JL
    J Appl Physiol (1985); 2005 Aug; 99(2):479-87. PubMed ID: 15790688
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Arterial gas embolism and hemoconcentration.
    Smith RM; Van Hoesen KB; Neuman TS
    J Emerg Med; 1994; 12(2):147-53. PubMed ID: 8207148
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Gas embolism and surfactant-based intervention: implications for long-duration space-based activity.
    Eckmann DM; Zhang J; Lampe J; Ayyaswamy PS
    Ann N Y Acad Sci; 2006 Sep; 1077():256-69. PubMed ID: 17124129
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Flow structures and red blood cell dynamics in arteriole of dilated or constricted cross section.
    Gambaruto AM
    J Biomech; 2016 Jul; 49(11):2229-2240. PubMed ID: 26822224
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A fully dynamical theory for the rate of arterial gas embolism growth and dissolution.
    Goldman S
    Math Biosci; 2022 Mar; 345():108793. PubMed ID: 35167830
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Endothelial nitric oxide synthase and calcium production in arterial geometries: an integrated fluid mechanics/cell model.
    Comerford A; Plank MJ; David T
    J Biomech Eng; 2008 Feb; 130(1):011010. PubMed ID: 18298186
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Multiple red blood cell flows through microvascular bifurcations: cell free layer, cell trajectory, and hematocrit separation.
    Yin X; Thomas T; Zhang J
    Microvasc Res; 2013 Sep; 89():47-56. PubMed ID: 23727384
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Hemodilution during venous gas embolization improves gas exchange, without altering V(A)/Q or pulmonary blood flow distributions.
    Deem S; McKinney S; Polissar NL; Hedges RG; Swenson ER
    Anesthesiology; 1999 Dec; 91(6):1861-72. PubMed ID: 10598631
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.