1. Significance of missing telemetered markers in implanted cardioverter-defibrillators. Barold SS; Stroobandt RX; Van Heuverswyn F; Herweg B Pacing Clin Electrophysiol; 2012 Apr; 35(4):409-15. PubMed ID: 22303882 [TBL] [Abstract][Full Text] [Related]
2. Functional atrial undersensing associated with switching to a tracking mode of pacing. Barold SS; Van Heuverswyn F; Timmers L; Stroobandt RX Pacing Clin Electrophysiol; 2012 Oct; 35(10):1188-93. PubMed ID: 22816428 [TBL] [Abstract][Full Text] [Related]
3. Pacemaker/defibrillator evaluation at Los Angeles County Department of Coroner*. Saint-Martin P; Rogers C; Muto J; Boyle NG; Rieders D; Sathyavagiswaran L J Forensic Sci; 2008 Sep; 53(5):1160-5. PubMed ID: 18637876 [TBL] [Abstract][Full Text] [Related]
4. [Stored intracardiac electrograms: accuracy of arrhythmia classification in patients with cardioverter/defibrillator system]. Neuzner J; Pitschner HF; König S; Stöhring R; Schlepper M Z Kardiol; 1993 Aug; 82(8):459-65. PubMed ID: 8212778 [TBL] [Abstract][Full Text] [Related]
5. Isoelectric PVCs diagnosed with a monitor with simultaneous ECG, and ICD intracardiac electrogram and marker channels. Scher DL; Man DC; Edery T; Lu S Pacing Clin Electrophysiol; 2009 Jan; 32(1):137-9. PubMed ID: 19140925 [TBL] [Abstract][Full Text] [Related]
6. Electrocardiogram-electrogram desynchronization while using radiofrequency wandless telemetry during implantation of an implantable cardioverter defibrillator. Cano O; Osca J; Buendía F; Sancho-Tello MJ; Olagüe J; Salvador A Europace; 2011 Feb; 13(2):291-2. PubMed ID: 20798116 [No Abstract] [Full Text] [Related]
7. Electromagnetic interference from welding and motors on implantable cardioverter-defibrillators as tested in the electrically hostile work site. Fetter JG; Benditt DG; Stanton MS J Am Coll Cardiol; 1996 Aug; 28(2):423-7. PubMed ID: 8800120 [TBL] [Abstract][Full Text] [Related]
9. [Implantable cardioverter-defibrillators in patients resuscitated from sudden death and in patients with sustained refractory ventricular tachycardia]. Adragão P; Parreira L; Neves J; Morgado F; Abecassis M; Almeida M; Martins D; Bonhorst D; Seabra-Gomes R Rev Port Cardiol; 1996 Mar; 15(3):195-206, 179, 181. PubMed ID: 8634168 [TBL] [Abstract][Full Text] [Related]
10. Multiple shocks after upgrade of an implantable cardioverter-defibrillator to a cardiac resynchronization therapy-defibrillator device. Francisco GM; Sharma S; Dougherty AH; Kantharia BK Cardiol J; 2009; 16(5):473-6. PubMed ID: 19753529 [TBL] [Abstract][Full Text] [Related]
11. Implantable cardioverter-defibrillators in patients with left ventricular noncompaction. Kobza R; Jenni R; Erne P; Oechslin E; Duru F Pacing Clin Electrophysiol; 2008 Apr; 31(4):461-7. PubMed ID: 18373765 [TBL] [Abstract][Full Text] [Related]
12. Temporary external implantable cardioverter defibrillator in the pacemaker-dependent ventricular tachycardia patient. Cooper JM; Lavi N; Polin GM; Dixit S; Verdino RJ Europace; 2011 May; 13(5):761-3. PubMed ID: 21106578 [No Abstract] [Full Text] [Related]
13. Reduction of ventricular tachyarrhythmia by treatment of atrial fibrillation in ICD patients with dual-chamber implantable cardioverter/defibrillators capable of atrial therapy delivery: the REVERT-AF Study. Gradaus R; Seidl K; Korte T; Himmrich E; Wieneke H; Schuchert A; Bauer W; Gerss J; Wollmann CG; Borggrefe M; Böcker D Europace; 2007 Jul; 9(7):534-9. PubMed ID: 17440005 [TBL] [Abstract][Full Text] [Related]
14. Effects of surgical and endoscopic electrocautery on modern-day permanent pacemaker and implantable cardioverter-defibrillator systems. Cheng A; Nazarian S; Spragg DD; Bilchick K; Tandri H; Mark L; Halperin H; Calkins H; Berger RD; Henrikson CA Pacing Clin Electrophysiol; 2008 Mar; 31(3):344-50. PubMed ID: 18307631 [TBL] [Abstract][Full Text] [Related]
15. [Dual-chamber implantable automatic defibrillators. Experiences apropos of 16 cases]. Le Franc P; Klug D; Lacroix D; Kouakam C; Jarwé M; Kacet S Arch Mal Coeur Vaiss; 1998 Jun; 91(6):739-44. PubMed ID: 9749190 [TBL] [Abstract][Full Text] [Related]
16. Left ventricular sensing and pacing for sensing difficulties in internal cardioverter defibrillator therapy for arrhythmogenic right ventricular cardiomyopathy. Lochy S; François B; Hollanders G; Provenier F Europace; 2010 Aug; 12(8):1195-6. PubMed ID: 20348554 [TBL] [Abstract][Full Text] [Related]