These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 2230860)

  • 21. [Analog-digital converter for an oscilloscope with digital memory].
    Godlevskiĭ PG; Gomza OB; Kats BM; Olifer BM; Tishchenko AG
    Nov Med Tekh; 1977; (4):45-8. PubMed ID: 616909
    [No Abstract]   [Full Text] [Related]  

  • 22. [A new modification to an indirect method of recording the arterial pressure in the tail artery of rats].
    Lapshin DN; Koshelev VB
    Fiziol Zh SSSR Im I M Sechenova; 1989 Feb; 75(2):282-6. PubMed ID: 2721772
    [No Abstract]   [Full Text] [Related]  

  • 23. Bone conduction auditory steady state response: investigations into reducing artifact.
    Brooke RE; Brennan SK; Stevens JC
    Ear Hear; 2009 Feb; 30(1):23-30. PubMed ID: 19050642
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A simple method to measure pulmonary artery pressure and central venous pressure with a single transducer.
    Pull ter Gunne AJ; Bruining HA
    Neth J Surg; 1984 Dec; 36(6):172-3. PubMed ID: 6521939
    [No Abstract]   [Full Text] [Related]  

  • 25. Sweep-frequency marker generator for blood pressure transducer testing.
    Lee AS
    J Clin Eng; 1983; 8(3):248-52. PubMed ID: 10263340
    [TBL] [Abstract][Full Text] [Related]  

  • 26. A 160 μA biopotential acquisition IC with fully integrated IA and motion artifact suppression.
    Van Helleputte N; Kim S; Kim H; Kim JP; Van Hoof C; Yazicioglu RF
    IEEE Trans Biomed Circuits Syst; 2012 Dec; 6(6):552-61. PubMed ID: 23853256
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Frequency response of fluid-filled catheter-micromanometer systems used for measurement of left ventricular pressure.
    Scruggs V; Pietras RJ; Rosen KM
    Am Heart J; 1975 May; 89(5):619-24. PubMed ID: 1119370
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Thin fluid-filled catheters for more accurate determination of pressures and their time derivatives.
    Lomholt N; Bille-Brahe NE; Andersen HR; Djuurhus JC; Bredgaard M
    Acta Chir Scand Suppl; 1980; 502():27-32. PubMed ID: 6941598
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Analysis: Electroencephalography Acquisition System: Analog Design.
    Alkhorshid DR; Molaeezadeh SF; Alkhorshid MR
    Biomed Instrum Technol; 2020 Sep; 54(5):346-351. PubMed ID: 33049766
    [TBL] [Abstract][Full Text] [Related]  

  • 30. An integrated system for multichannel neuronal recording with spike/LFP separation, integrated A/D conversion and threshold detection.
    Perelman Y; Ginosar R
    IEEE Trans Biomed Eng; 2007 Jan; 54(1):130-7. PubMed ID: 17260864
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Continuous ambulatory pulmonary artery pressure monitoring. A new method using a transducer tipped catheter and a simple recording system.
    Levy RD; Cunningham D; Shapiro LM; Wright C; Mockus L; Fox KM
    Br Heart J; 1986 Apr; 55(4):336-43. PubMed ID: 3964499
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Dynamic response of liquid-filled catheter systems for measurement of blood pressure: precision of measurements and reliability of the Pressure Recording Analytical Method with different disposable systems.
    Romagnoli S; Romano SM; Bevilacqua S; Lazzeri C; Gensini GF; Pratesi C; Quattrone D; Dini D; De Gaudio AR
    J Crit Care; 2011 Aug; 26(4):415-22. PubMed ID: 21036533
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Investigation of basic imaging properties in digital radiography. 2. Noise Wiener spectrum.
    Giger ML; Doi K; Metz CE
    Med Phys; 1984; 11(6):797-805. PubMed ID: 6513887
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Sampling rate effects on surface EMG timing and amplitude measures.
    Ives JC; Wigglesworth JK
    Clin Biomech (Bristol, Avon); 2003 Jul; 18(6):543-52. PubMed ID: 12828904
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Bipolar analog-digital converter of sequential counting on integral circuits].
    Mikhlin BS; Bulgakov SP; Kulikov MI
    Nov Med Tekh; 1978; (3):54-7. PubMed ID: 755984
    [No Abstract]   [Full Text] [Related]  

  • 36. High-fidelity digital recording and playback sphygmomanometry system: device description and proof of concept.
    Lee J; Chee Y; Kim I; Karpettas N; Kollias A; Atkins N; Stergiou GS; O'Brien E
    Blood Press Monit; 2015 Oct; 20(5):266-72. PubMed ID: 26075332
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Analog frontend for multichannel neuronal recording system with spike and LFP separation.
    Perelman Y; Ginosar R
    J Neurosci Methods; 2006 May; 153(1):21-6. PubMed ID: 16337276
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Design and development of a new electronic sphygmomanometer.
    Vachtsevanos GJ; Kalaitzakis KC; Papamarkos NE
    Med Biol Eng Comput; 1985 Sep; 23(5):453-8. PubMed ID: 4068779
    [No Abstract]   [Full Text] [Related]  

  • 39. Long term assessment of blood pressure transducer drift in rhesus monkeys chronically instrumented with telemetry implants.
    Regan HK; Lynch JJ; Regan CP
    J Pharmacol Toxicol Methods; 2009; 59(1):35-8. PubMed ID: 18983927
    [TBL] [Abstract][Full Text] [Related]  

  • 40. The frequency response of external transducer blood pressure measurement systems: a theoretical and experimental study.
    Yeomanson CW; Evans DH
    Clin Phys Physiol Meas; 1983 Nov; 4(4):435-49. PubMed ID: 6653046
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.