These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

94 related articles for article (PubMed ID: 22309386)

  • 1. Unrecognized failure of a narrow caliber defibrillation lead: the role of defibrillation threshold testing in identifying an unprotected individual.
    Leong DP; van Erven L
    Pacing Clin Electrophysiol; 2012 Jun; 35(6):e154-5. PubMed ID: 22309386
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Pulse Generator Exchange Does Not Accelerate the Rate of Electrical Failure in a Recalled Small Caliber ICD Lead.
    Lovelock JD; Premkumar A; Levy MR; Mengistu A; Hoskins MH; El-Chami MF; Lloyd MS; Leon AR; Langberg JJ; Delurgio DB
    Pacing Clin Electrophysiol; 2015 Dec; 38(12):1434-8. PubMed ID: 26285670
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Failure to deliver therapy by a Riata Lead with internal wire externalization and normal electrical parameters during routine interrogation.
    Shah P; Singh G; Chandra S; Schuger CD
    J Cardiovasc Electrophysiol; 2013 Jan; 24(1):94-6. PubMed ID: 22612668
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Update on small-diameter implantable cardioverter-defibrillator leads performance.
    van Rees JB; van Welsenes GH; Borleffs CJ; Thijssen J; van der Velde ET; van der Wall EE; van Erven L; Schalij MJ
    Pacing Clin Electrophysiol; 2012 Jun; 35(6):652-8. PubMed ID: 22352338
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Detection of a Riata™ insulation failure by the Medtronic Lead Integrity Alert™.
    Kneller J; Delacey W; Wood MA; Ellenbogen KA
    Europace; 2012 Aug; 14(8):1215-6. PubMed ID: 22371526
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Conductor externalization of the Riata internal cardioverter defibrillator lead: tip of the iceberg? Report of three cases and review of literature.
    Dorman HG; van Opstal JM; Stevenhagen J; Scholten MF
    Europace; 2012 Aug; 14(8):1161-4. PubMed ID: 22431444
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Sudden and Fatal Malfunction of a Durata Defibrillator Lead due to External Insulation Failure.
    Shah AD; Hirsh DS; Langberg JJ
    Pacing Clin Electrophysiol; 2016 Jan; 39(1):101-4. PubMed ID: 26293817
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Prevention of inappropriate ICD shocks due to lead insulation failure by continuous monitoring and automatic alert.
    Gelder RN; Gunderson BD
    Pacing Clin Electrophysiol; 2012 Jun; 35(6):e150-3. PubMed ID: 22309317
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Fluoroscopic and electrical assessment of a series of defibrillation leads: prevalence of externalized conductors.
    Kodoth VN; Hodkinson EC; Noad RL; Ashfield KP; Cromie NA; McEneaney DJ; Wilson CM; Roberts MJ
    Pacing Clin Electrophysiol; 2012 Dec; 35(12):1498-504. PubMed ID: 23035735
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Premature failure of a Riata defibrillator lead without impedance change or inappropriate sensing: a case report and review of the literature.
    Krebsbach A; Alhumaid F; Henrikson CA; Calkins H; Berger RD; Cheng A
    J Cardiovasc Electrophysiol; 2011 Sep; 22(9):1070-2. PubMed ID: 21385268
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Prevalence of asymptomatic and electrically undetectable intracardiac inside-out abrasion in silicon-coated Riata® and Riata® ST implantable cardioverter-defibrillator leads.
    Schmutz M; Delacrétaz E; Schwick N; Roten L; Fuhrer J; Boesch C; Tanner H
    Int J Cardiol; 2013 Jul; 167(1):254-7. PubMed ID: 22236515
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A plea for delivery of high-voltage shocks during implantable cardioverter-defibrillator replacement or system upgrade.
    Sticherling C; Schaer B; Kühne M; Osswald S
    Can J Cardiol; 2012; 28(5):611.e5-6. PubMed ID: 22498180
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Estimation of defibrillation threshold using abdominally implanted cardioverter-defibrillator with an additional defibrillation pole in a dual-coil lead endocardial defibrillation system].
    Pazdyga A; Lubiński A; Lewicka-Nowak E; Królak T; Kempa M; Zienciuk A; Raczak G
    Pol Merkur Lekarski; 2007 Feb; 22(128):86-9. PubMed ID: 17598649
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Progressive decrease in amplitude of intracardiac ventricular electrogram and higher left ventricular ejection fraction are associated with conductors' externalization in Riata leads.
    Kubala M; Traullé S; Leborgne L; Hermida JS
    Europace; 2013 Aug; 15(8):1198-204. PubMed ID: 23388185
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of >10 years.
    Kleemann T; Becker T; Doenges K; Vater M; Senges J; Schneider S; Saggau W; Weisse U; Seidl K
    Circulation; 2007 May; 115(19):2474-80. PubMed ID: 17470696
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Inductionless or limited shock testing is possible in most patients with implantable cardioverter- defibrillators/cardiac resynchronization therapy defibrillators: results of the multicenter ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduction Evaluation With Implantable Cardioverter-Defibrillator Implantations).
    Day JD; Doshi RN; Belott P; Birgersdotter-Green U; Behboodikhah M; Ott P; Glatter KA; Tobias S; Frumin H; Lee BK; Merillat J; Wiener I; Wang S; Grogin H; Chun S; Patrawalla R; Crandall B; Osborn JS; Weiss JP; Lappe DL; Neuman S
    Circulation; 2007 May; 115(18):2382-9. PubMed ID: 17470697
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Does size really matter? A comparison of the Riata lead family based on size and its relation to performance.
    Corbisiero R; Armbruster R
    Pacing Clin Electrophysiol; 2008 Jun; 31(6):722-6. PubMed ID: 18507545
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Electrical failure of an ICD lead due to a presumed insulation defect only diagnosed by a maximum output shock.
    Goldstein MA; Badri M; Kocovic D; Kowey PR
    Pacing Clin Electrophysiol; 2013 Sep; 36(9):1068-71. PubMed ID: 23731252
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fluoroscopic screening of asymptomatic patients implanted with the recalled Riata lead family.
    Liu J; Rattan R; Adelstein E; Barrington W; Bazaz R; Brode S; Jain S; Mendenhall GS; Nemec J; Razak E; Shalaby A; Schwartzman D; Voigt A; Wang NC; Saba S
    Circ Arrhythm Electrophysiol; 2012 Aug; 5(4):809-14. PubMed ID: 22787015
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Lead thrombi associated with externalized cables on Riata ICD leads: a case series.
    Goyal SK; Ellis CR; Rottman JN; Whalen SP
    J Cardiovasc Electrophysiol; 2013 Sep; 24(9):1047-50. PubMed ID: 23577693
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.