94 related articles for article (PubMed ID: 22309386)
1. Unrecognized failure of a narrow caliber defibrillation lead: the role of defibrillation threshold testing in identifying an unprotected individual. Leong DP; van Erven L Pacing Clin Electrophysiol; 2012 Jun; 35(6):e154-5. PubMed ID: 22309386 [TBL] [Abstract][Full Text] [Related]
2. Pulse Generator Exchange Does Not Accelerate the Rate of Electrical Failure in a Recalled Small Caliber ICD Lead. Lovelock JD; Premkumar A; Levy MR; Mengistu A; Hoskins MH; El-Chami MF; Lloyd MS; Leon AR; Langberg JJ; Delurgio DB Pacing Clin Electrophysiol; 2015 Dec; 38(12):1434-8. PubMed ID: 26285670 [TBL] [Abstract][Full Text] [Related]
3. Failure to deliver therapy by a Riata Lead with internal wire externalization and normal electrical parameters during routine interrogation. Shah P; Singh G; Chandra S; Schuger CD J Cardiovasc Electrophysiol; 2013 Jan; 24(1):94-6. PubMed ID: 22612668 [TBL] [Abstract][Full Text] [Related]
4. Update on small-diameter implantable cardioverter-defibrillator leads performance. van Rees JB; van Welsenes GH; Borleffs CJ; Thijssen J; van der Velde ET; van der Wall EE; van Erven L; Schalij MJ Pacing Clin Electrophysiol; 2012 Jun; 35(6):652-8. PubMed ID: 22352338 [TBL] [Abstract][Full Text] [Related]
5. Detection of a Riata™ insulation failure by the Medtronic Lead Integrity Alert™. Kneller J; Delacey W; Wood MA; Ellenbogen KA Europace; 2012 Aug; 14(8):1215-6. PubMed ID: 22371526 [TBL] [Abstract][Full Text] [Related]
6. Conductor externalization of the Riata internal cardioverter defibrillator lead: tip of the iceberg? Report of three cases and review of literature. Dorman HG; van Opstal JM; Stevenhagen J; Scholten MF Europace; 2012 Aug; 14(8):1161-4. PubMed ID: 22431444 [TBL] [Abstract][Full Text] [Related]
7. Sudden and Fatal Malfunction of a Durata Defibrillator Lead due to External Insulation Failure. Shah AD; Hirsh DS; Langberg JJ Pacing Clin Electrophysiol; 2016 Jan; 39(1):101-4. PubMed ID: 26293817 [TBL] [Abstract][Full Text] [Related]
8. Prevention of inappropriate ICD shocks due to lead insulation failure by continuous monitoring and automatic alert. Gelder RN; Gunderson BD Pacing Clin Electrophysiol; 2012 Jun; 35(6):e150-3. PubMed ID: 22309317 [TBL] [Abstract][Full Text] [Related]
9. Fluoroscopic and electrical assessment of a series of defibrillation leads: prevalence of externalized conductors. Kodoth VN; Hodkinson EC; Noad RL; Ashfield KP; Cromie NA; McEneaney DJ; Wilson CM; Roberts MJ Pacing Clin Electrophysiol; 2012 Dec; 35(12):1498-504. PubMed ID: 23035735 [TBL] [Abstract][Full Text] [Related]
10. Premature failure of a Riata defibrillator lead without impedance change or inappropriate sensing: a case report and review of the literature. Krebsbach A; Alhumaid F; Henrikson CA; Calkins H; Berger RD; Cheng A J Cardiovasc Electrophysiol; 2011 Sep; 22(9):1070-2. PubMed ID: 21385268 [TBL] [Abstract][Full Text] [Related]
11. Prevalence of asymptomatic and electrically undetectable intracardiac inside-out abrasion in silicon-coated Riata® and Riata® ST implantable cardioverter-defibrillator leads. Schmutz M; Delacrétaz E; Schwick N; Roten L; Fuhrer J; Boesch C; Tanner H Int J Cardiol; 2013 Jul; 167(1):254-7. PubMed ID: 22236515 [TBL] [Abstract][Full Text] [Related]
12. A plea for delivery of high-voltage shocks during implantable cardioverter-defibrillator replacement or system upgrade. Sticherling C; Schaer B; Kühne M; Osswald S Can J Cardiol; 2012; 28(5):611.e5-6. PubMed ID: 22498180 [TBL] [Abstract][Full Text] [Related]
13. [Estimation of defibrillation threshold using abdominally implanted cardioverter-defibrillator with an additional defibrillation pole in a dual-coil lead endocardial defibrillation system]. Pazdyga A; Lubiński A; Lewicka-Nowak E; Królak T; Kempa M; Zienciuk A; Raczak G Pol Merkur Lekarski; 2007 Feb; 22(128):86-9. PubMed ID: 17598649 [TBL] [Abstract][Full Text] [Related]
14. Progressive decrease in amplitude of intracardiac ventricular electrogram and higher left ventricular ejection fraction are associated with conductors' externalization in Riata leads. Kubala M; Traullé S; Leborgne L; Hermida JS Europace; 2013 Aug; 15(8):1198-204. PubMed ID: 23388185 [TBL] [Abstract][Full Text] [Related]
15. Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of >10 years. Kleemann T; Becker T; Doenges K; Vater M; Senges J; Schneider S; Saggau W; Weisse U; Seidl K Circulation; 2007 May; 115(19):2474-80. PubMed ID: 17470696 [TBL] [Abstract][Full Text] [Related]
16. Inductionless or limited shock testing is possible in most patients with implantable cardioverter- defibrillators/cardiac resynchronization therapy defibrillators: results of the multicenter ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduction Evaluation With Implantable Cardioverter-Defibrillator Implantations). Day JD; Doshi RN; Belott P; Birgersdotter-Green U; Behboodikhah M; Ott P; Glatter KA; Tobias S; Frumin H; Lee BK; Merillat J; Wiener I; Wang S; Grogin H; Chun S; Patrawalla R; Crandall B; Osborn JS; Weiss JP; Lappe DL; Neuman S Circulation; 2007 May; 115(18):2382-9. PubMed ID: 17470697 [TBL] [Abstract][Full Text] [Related]
17. Does size really matter? A comparison of the Riata lead family based on size and its relation to performance. Corbisiero R; Armbruster R Pacing Clin Electrophysiol; 2008 Jun; 31(6):722-6. PubMed ID: 18507545 [TBL] [Abstract][Full Text] [Related]
18. Electrical failure of an ICD lead due to a presumed insulation defect only diagnosed by a maximum output shock. Goldstein MA; Badri M; Kocovic D; Kowey PR Pacing Clin Electrophysiol; 2013 Sep; 36(9):1068-71. PubMed ID: 23731252 [TBL] [Abstract][Full Text] [Related]
19. Fluoroscopic screening of asymptomatic patients implanted with the recalled Riata lead family. Liu J; Rattan R; Adelstein E; Barrington W; Bazaz R; Brode S; Jain S; Mendenhall GS; Nemec J; Razak E; Shalaby A; Schwartzman D; Voigt A; Wang NC; Saba S Circ Arrhythm Electrophysiol; 2012 Aug; 5(4):809-14. PubMed ID: 22787015 [TBL] [Abstract][Full Text] [Related]
20. Lead thrombi associated with externalized cables on Riata ICD leads: a case series. Goyal SK; Ellis CR; Rottman JN; Whalen SP J Cardiovasc Electrophysiol; 2013 Sep; 24(9):1047-50. PubMed ID: 23577693 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]