These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Effect of mattress deflection on CPR quality assessment for older children and adolescents. Nishisaki A; Nysaether J; Sutton R; Maltese M; Niles D; Donoghue A; Bishnoi R; Helfaer M; Perkins GD; Berg R; Arbogast K; Nadkarni V Resuscitation; 2009 May; 80(5):540-5. PubMed ID: 19342150 [TBL] [Abstract][Full Text] [Related]
4. The impact of backboard size and orientation on sternum-to-spine compression depth and compression stiffness in a manikin study of CPR using two mattress types. Cloete G; Dellimore KH; Scheffer C; Smuts MS; Wallis LA Resuscitation; 2011 Aug; 82(8):1064-70. PubMed ID: 21601344 [TBL] [Abstract][Full Text] [Related]
5. Compression feedback devices over estimate chest compression depth when performed on a bed. Perkins GD; Kocierz L; Smith SC; McCulloch RA; Davies RP Resuscitation; 2009 Jan; 80(1):79-82. PubMed ID: 18952361 [TBL] [Abstract][Full Text] [Related]
6. Manual versus Mechanical Chest Compressions on Surfaces of Varying Softness with or without Backboards: A Randomized, Crossover Manikin Study. Putzer G; Fiala A; Braun P; Neururer S; Biechl K; Keilig B; Ploner W; Fop E; Paal P J Emerg Med; 2016 Apr; 50(4):594-600.e1. PubMed ID: 26607696 [TBL] [Abstract][Full Text] [Related]
7. Use of backboard and deflation improve quality of chest compression when cardiopulmonary resuscitation is performed on a typical air inflated mattress configuration. Oh J; Kang H; Chee Y; Lim T; Song Y; Cho Y; Je S J Korean Med Sci; 2013 Feb; 28(2):315-9. PubMed ID: 23399985 [TBL] [Abstract][Full Text] [Related]
8. Can support surfaces characteristics influence high-quality chest compression? manikin experiment with a mechanical device. Vianna CA; Campos JF; de Oliveira HC; Machado DM; de Bakker GB; da Silva RC; Brandão MAG Heart Lung; 2023; 57():180-185. PubMed ID: 36228538 [TBL] [Abstract][Full Text] [Related]
9. Backboard insertion in the operating table increases chest compression depth: a manikin study. Sato H; Komasawa N; Ueki R; Yamamoto N; Fujii A; Nishi S; Kaminoh Y J Anesth; 2011 Oct; 25(5):770-2. PubMed ID: 21739192 [TBL] [Abstract][Full Text] [Related]
10. The Impact of Backboard Placement on Chest Compression Quality: A Mannequin Study. Sanri E; Karacabey S Prehosp Disaster Med; 2019 Apr; 34(2):182-187. PubMed ID: 30981288 [TBL] [Abstract][Full Text] [Related]
11. Effect of mattress and bed frame deflection on real chest compression depth measured with two CPR sensors. Sainio M; Hellevuo H; Huhtala H; Hoppu S; Eilevstjønn J; Tenhunen J; Olkkola KT Resuscitation; 2014 Jun; 85(6):840-3. PubMed ID: 24657249 [TBL] [Abstract][Full Text] [Related]
12. Effect of Emergency Department Mattress Compressibility on Chest Compression Depth Using a Standardized Cardiopulmonary Resuscitation Board, a Slider Transfer Board, and a Flat Spine Board: A Simulation-Based Study. Cheng A; Belanger C; Wan B; Davidson J; Lin Y Simul Healthc; 2017 Dec; 12(6):364-369. PubMed ID: 28697056 [TBL] [Abstract][Full Text] [Related]
13. Proper target depth of an accelerometer-based feedback device during CPR performed on a hospital bed: a randomized simulation study. Lee S; Oh J; Kang H; Lim T; Kim W; Chee Y; Song Y; Ahn C; Cho JH Am J Emerg Med; 2015 Oct; 33(10):1425-9. PubMed ID: 26298053 [TBL] [Abstract][Full Text] [Related]
14. The impact of compliant surfaces on in-hospital chest compressions: effects of common mattresses and a backboard. Noordergraaf GJ; Paulussen IW; Venema A; van Berkom PF; Woerlee PH; Scheffer GJ; Noordergraaf A Resuscitation; 2009 May; 80(5):546-52. PubMed ID: 19409300 [TBL] [Abstract][Full Text] [Related]
15. Effect of a dynamic mattress on chest compression quality during cardiopulmonary resuscitation. Torsy T; Deswarte W; Karlberg Traav M; Beeckman D Nurs Crit Care; 2022 Mar; 27(2):275-281. PubMed ID: 33884701 [TBL] [Abstract][Full Text] [Related]
16. A novel method to decrease mattress compression during CPR using a mattress compression cover and a vacuum pump. Oh J; Chee Y; Song Y; Lim T; Kang H; Cho Y Resuscitation; 2013 Jul; 84(7):987-91. PubMed ID: 23318913 [TBL] [Abstract][Full Text] [Related]
17. The use of dual accelerometers improves measurement of chest compression depth. Oh J; Song Y; Kang B; Kang H; Lim T; Suh Y; Chee Y Resuscitation; 2012 Apr; 83(4):500-4. PubMed ID: 22001002 [TBL] [Abstract][Full Text] [Related]
18. Effects of a backboard, bed height, and operator position on compression depth during simulated resuscitation. Perkins GD; Smith CM; Augre C; Allan M; Rogers H; Stephenson B; Thickett DR Intensive Care Med; 2006 Oct; 32(10):1632-5. PubMed ID: 16826385 [TBL] [Abstract][Full Text] [Related]
19. Accurate feedback of chest compression depth on a manikin on a soft surface with correction for total body displacement. Beesems SG; Koster RW Resuscitation; 2014 Nov; 85(11):1439-43. PubMed ID: 25150184 [TBL] [Abstract][Full Text] [Related]
20. Comparison of experimental chest compression data to a theoretical model for the mechanics of constant peak displacement cardiopulmonary resuscitation. Cloete G; Dellimore KH; Scheffer C Acad Emerg Med; 2011 Nov; 18(11):1167-76. PubMed ID: 22092898 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]