BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

147 related articles for article (PubMed ID: 2231457)

  • 1. Gravity-induced stresses by an obturator prosthesis.
    Schwartzman B; Caputo AA; Beumer J
    J Prosthet Dent; 1990 Oct; 64(4):466-8. PubMed ID: 2231457
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Occlusal force transfer by removable partial denture designs for a radical maxillectomy.
    Schwartzman B; Caputo A; Beumer J
    J Prosthet Dent; 1985 Sep; 54(3):397-403. PubMed ID: 3906096
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Finite element method analysis of the stress distribution to supporting tissues in a Class IV Aramany removable partial denture (Part I: the teeth and periodontal ligament).
    Gharechahi J; Sharifi E; Aghdaee NA; Nosohian S
    J Contemp Dent Pract; 2008 Sep; 9(6):65-72. PubMed ID: 18784861
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A photoelastic study of stress induced by framework design in a maxillary resection.
    Myers RE; Mitchell DL
    J Prosthet Dent; 1989 May; 61(5):590-4. PubMed ID: 2664145
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Retention of obturator-removable partial dentures: a comparison of buccal and lingual retention.
    Firtell DN; Grisius RJ
    J Prosthet Dent; 1980 Feb; 43(2):212-7. PubMed ID: 6985968
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Abutment load transfer by removable partial denture obturator frameworks in different acquired maxillary defects.
    Lyons KM; Beumer J; Caputo AA
    J Prosthet Dent; 2005 Sep; 94(3):281-8. PubMed ID: 16126081
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Basic principles of obturator design for partially edentulous patients. Part II: design principles.
    Aramany MA
    J Prosthet Dent; 1978 Dec; 40(6):656-62. PubMed ID: 364026
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Review of removable partial denture components and their design as related to maintenance of tissue health.
    Weintraub GS
    Dent Clin North Am; 1985 Jan; 29(1):39-56. PubMed ID: 3882475
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Swinglock removable partial denture and biting forces in partially edentulous patients. Comparison of individual biting forces with and without swinglock removable partial denture.
    Mizukawa K; Mega J
    J Nihon Univ Sch Dent; 1993 Sep; 35(3):204-8. PubMed ID: 8246044
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Finite element method analysis of stress distribution to supporting tissues in a Class IV Aramany removable partial denture (Part II: bone and mucosal membrane).
    Gharechahi J; Sharifi E; Nosohian S; Aghdaee NA
    J Contemp Dent Pract; 2008 Nov; 9(7):49-56. PubMed ID: 18997916
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Swing-lock design considerations for obturator frameworks.
    Parr GR; Gardner LK
    J Prosthet Dent; 1995 Nov; 74(5):503-11. PubMed ID: 8809257
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Resin bonded attachments for maxillary obturator retention: a clinical report.
    Grossmann Y; Madjar D
    J Prosthet Dent; 2004 Sep; 92(3):229-32. PubMed ID: 15343156
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Force transmission by indirect retainers when a unilateral dislodging force is applied.
    McDowell GC; Fisher RL
    J Prosthet Dent; 1982 Apr; 47(4):360-5. PubMed ID: 7040637
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Obturator design for hemimaxillectomy patients.
    Javid NS; Dadmanesh J
    J Prosthet Dent; 1976 Jul; 36(1):77-81. PubMed ID: 787503
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Removable partial denture framework try-in.
    Wong MT; Calverley MJ; Nagy WW
    J Prosthet Dent; 1993 Apr; 69(4):363-8. PubMed ID: 8463963
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Retention magnets in guiding plates of distal-extension removable partial dentures.
    Pezzoli M; Highton R; Caputo A; Matyas J
    J Prosthet Dent; 1988 Nov; 60(5):577-82. PubMed ID: 3058939
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Photoelastic analysis and comparison of force-transmission characteristics of intracoronal attachments with clasp distal-extension removable partial dentures.
    Chou TM; Caputo AA; Moore DJ; Xiao B
    J Prosthet Dent; 1989 Sep; 62(3):313-9. PubMed ID: 2681701
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A fixed-removable partial denture for cleft-palate patients.
    Immekus JE; Aramany M
    J Prosthet Dent; 1975 Sep; 34(3):286-91. PubMed ID: 22334990
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Dental stresses in the consideration of the biomechanical design of removable partial dentures].
    Rodriguez Gonzalez MA; Casado Llompart JR; Ballina Peruyera A
    Av Odontoestomatol; 1986; 2(6):288-90, 293-4, 297-9. PubMed ID: 3548742
    [No Abstract]   [Full Text] [Related]  

  • 20. Design for maximal retention of obturator prosthesis for hemimaxillectomy patients.
    Wright SM; Pullen-Warner EA; Le Tissier DR
    J Prosthet Dent; 1982 Jan; 47(1):88-91. PubMed ID: 7033517
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 8.