152 related articles for article (PubMed ID: 22322519)
21. A novel technique for measurement of orthodontic mini-implant stability using the Osstell ISQ device.
Hosein YK; Dixon SJ; Rizkalla AS; Tassi A
Angle Orthod; 2019 Mar; 89(2):284-291. PubMed ID: 30382751
[TBL] [Abstract][Full Text] [Related]
22. A comparative study on the accuracy of the devices for measuring the implant stability.
Cho IH; Lee YI; Kim YM
J Adv Prosthodont; 2009 Nov; 1(3):124-8. PubMed ID: 21165267
[TBL] [Abstract][Full Text] [Related]
23. The comparison between implant stability quotient and bone-implant contact revisited: an experiment in Beagle dog.
Manresa C; Bosch M; Echeverría JJ
Clin Oral Implants Res; 2014 Nov; 25(11):1213-1221. PubMed ID: 24102812
[TBL] [Abstract][Full Text] [Related]
24. Osstell Resonance Frequency Measurement Values as a Prognostic Factor in Implant Dentistry.
Krafft T; Graef F; Karl M
J Oral Implantol; 2015 Aug; 41(4):e133-7. PubMed ID: 24766132
[TBL] [Abstract][Full Text] [Related]
25. Resonance frequency analysis of implants placed with osteotome sinus floor elevation in posterior maxillae.
Qian SJ; Gu YX; Mo JJ; Qiao SC; Zhuang LF; Lai HC
Clin Oral Implants Res; 2016 Jan; 27(1):113-9. PubMed ID: 25521163
[TBL] [Abstract][Full Text] [Related]
26. In vitro comparison of resonance frequency analysis devices to evaluate implant stability of narrow diameter implants at varying drilling speeds in dense artificial bone blocks.
Romanos GE; Bastardi DJ; Kakar A; Moore R; Delgado-Ruiz RA; Javed F
Clin Implant Dent Relat Res; 2019 Oct; 21(5):1023-1027. PubMed ID: 31464362
[TBL] [Abstract][Full Text] [Related]
27. An evaluation of the resonance frequency analysis device: examiner reliability and repeatability of readings.
Gupta RK; Padmanabhan TV
J Oral Implantol; 2013 Dec; 39(6):704-7. PubMed ID: 21970725
[TBL] [Abstract][Full Text] [Related]
28. Resonance frequency measurements in vivo and related surface properties of magnesium-incorporated, micropatterned and magnesium-incorporated TiUnite, Osseotite, SLA and TiOblast implants.
Sul YT; Jönsson J; Yoon GS; Johansson C
Clin Oral Implants Res; 2009 Oct; 20(10):1146-55. PubMed ID: 19719742
[TBL] [Abstract][Full Text] [Related]
29. Correlation between resonance frequency, insertion torque and bone-implant contact in self-cutting threaded implants.
Açil Y; Sievers J; Gülses A; Ayna M; Wiltfang J; Terheyden H
Odontology; 2017 Jul; 105(3):347-353. PubMed ID: 27538921
[TBL] [Abstract][Full Text] [Related]
30. Clinical study of the relationship between implant stability measurements using Periotest and Osstell mentor and bone quality assessment.
Oh JS; Kim SG
Oral Surg Oral Med Oral Pathol Oral Radiol; 2012 Mar; 113(3):e35-40. PubMed ID: 22669155
[TBL] [Abstract][Full Text] [Related]
31. Reliability of 2 implant stability measuring methods in assessment of various periimplant bone loss: an in vitro study with the Periotest and Osstell Mentor.
Choi HH; Chung CH; Kim SG; Son MK
Implant Dent; 2014 Feb; 23(1):51-6. PubMed ID: 24398847
[TBL] [Abstract][Full Text] [Related]
32. A comparative study of the Osstell™ versus the Osstell Mentor™ to evaluate implant stability in human cadaver mandibles.
Snijders RS; van Wijk AJ; Lindeboom JA
J Oral Rehabil; 2013 Oct; 40(10):774-9. PubMed ID: 23981012
[TBL] [Abstract][Full Text] [Related]
33. Diagnosis of implant stability and its impact on implant survival: a prospective case series study.
Rodrigo D; Aracil L; Martin C; Sanz M
Clin Oral Implants Res; 2010 Mar; 21(3):255-61. PubMed ID: 19958375
[TBL] [Abstract][Full Text] [Related]
34. A prospective case-control clinical trial comparing 1- and 2-stage Nobel Biocare TiUnite implants: resonance frequency analysis assessed by Osstell Mentor during integration.
Tallarico M; Vaccarella A; Marzi GC; Alviani A; Campana V
Quintessence Int; 2011 Sep; 42(8):635-44. PubMed ID: 21842003
[TBL] [Abstract][Full Text] [Related]
35. Implant stability comparison of immediate and delayed maxillary implant placement by use of resonance frequency analysis--a clinical study.
Granić M; Katanec D; Vučićević Boras V; Sušić M; Jurič IB; Gabrić D
Acta Clin Croat; 2015 Mar; 54(1):3-8. PubMed ID: 26058235
[TBL] [Abstract][Full Text] [Related]
36. Stability measurements of osseointegrated implants using Osstell in partially edentulous jaws after 1 year of loading: a pilot study.
Balleri P; Cozzolino A; Ghelli L; Momicchioli G; Varriale A
Clin Implant Dent Relat Res; 2002; 4(3):128-32. PubMed ID: 12516644
[TBL] [Abstract][Full Text] [Related]
37. Is Acoustic modal analysis a reliable substitution for Osstell® device in dental implant stability assessment? An experimental and finite element analysis study.
Alimoradi N; Einafshar M; Amid R; Hashemi A
Med Oral Patol Oral Cir Bucal; 2024 Jan; 29(3):e362-9. PubMed ID: 38288850
[TBL] [Abstract][Full Text] [Related]
38. In vitro evaluation of the influence of the cortical bone on the primary stability of two implant systems.
Andrés-García R; Vives NG; Climent FH; Palacín AF; Santos VR; Climent MH; Bullón P
Med Oral Patol Oral Cir Bucal; 2009 Feb; 14(2):E93-7. PubMed ID: 19179957
[TBL] [Abstract][Full Text] [Related]
39. Resonance Frequency Analysis of Thermal Acid-Etched, Hydrophilic Implants During First 3 Months of Healing and Osseointegration in an Early-Loading Protocol.
van Eekeren P; Said C; Tahmaseb A; Wismeijer D
Int J Oral Maxillofac Implants; 2015; 30(4):843-50. PubMed ID: 26252037
[TBL] [Abstract][Full Text] [Related]
40. Influence of Skeletal and Local Bone Density on Dental Implant Stability in Patients with Osteoporosis.
Merheb J; Temmerman A; Rasmusson L; Kübler A; Thor A; Quirynen M
Clin Implant Dent Relat Res; 2016 Apr; 18(2):253-60. PubMed ID: 26864614
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]