These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

103 related articles for article (PubMed ID: 22323278)

  • 1. In vivo and in vitro sonographic diagnosis of an encrusted nephrostomy catheter with color doppler twinkling artifact.
    Lin CW; Yen TH; Cheng CL; Huang HH; Kang RJ; Gueng MK; Lin YC; Tyan YS; Tsao TF
    J Clin Ultrasound; 2013; 41(3):175-7. PubMed ID: 22323278
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Sonographic diagnosis of symptomatic ureteral calculi: usefulness of the twinkling artifact.
    Ripollés T; Martínez-Pérez MJ; Vizuete J; Miralles S; Delgado F; Pastor-Navarro T
    Abdom Imaging; 2013 Aug; 38(4):863-9. PubMed ID: 23011549
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Twinkling artifact in color Doppler ultrasonography: pictorial essay].
    Conkbayir I; Yanik B; Senyücel C; Hekimoğlu B
    Tani Girisim Radyol; 2003 Dec; 9(4):407-10. PubMed ID: 14730947
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Color Doppler twinkling artifact in intrauterine fetal demise.
    Ozkur A; Dikensoy E; Kervancioglu S; Kervancioglu R; Inalöz S; Bayram M
    J Clin Ultrasound; 2008; 36(3):153-6. PubMed ID: 17565755
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Sonographic twinkling artifact for renal calculus detection: correlation with CT.
    Dillman JR; Kappil M; Weadock WJ; Rubin JM; Platt JF; DiPietro MA; Bude RO
    Radiology; 2011 Jun; 259(3):911-6. PubMed ID: 21460031
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The reliability of color doppler "twinkling" artifact for diagnosing millimetrical nephrolithiasis: comparison with B-Mode US and CT scanning results.
    Yavuz A; Ceken K; Alimoglu E; Kabaalioglu A
    J Med Ultrason (2001); 2015 Apr; 42(2):215-22. PubMed ID: 26576575
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Color Doppler twinkling artifact in hyperechoic regions.
    Rahmouni A; Bargoin R; Herment A; Bargoin N; Vasile N
    Radiology; 1996 Apr; 199(1):269-71. PubMed ID: 8633158
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Clinical Significance of Twinkling Artifact in the Diagnosis of Urinary Stones.
    Bacha R; Manzoor I; Gilani SA; Khan AI
    Ultrasound Med Biol; 2019 Dec; 45(12):3199-3206. PubMed ID: 31537388
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Correlation between twinkling artifact and color Doppler carrier frequency: preliminary observations in renal calculi.
    Gao J; Hentel K; Rubin JM
    Ultrasound Med Biol; 2012 Sep; 38(9):1534-9. PubMed ID: 22698502
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Color Doppler twinkling artifacts in various conditions during abdominal and pelvic sonography.
    Kim HC; Yang DM; Jin W; Ryu JK; Shin HC
    J Ultrasound Med; 2010 Apr; 29(4):621-32. PubMed ID: 20375381
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison between color Doppler twinkling artifact and acoustic shadowing for renal calculus detection: an in vitro study.
    Shabana W; Bude RO; Rubin JM
    Ultrasound Med Biol; 2009 Feb; 35(2):339-50. PubMed ID: 19041171
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Safe removal of an encrusted nephrostomy tube using a vascular sheath: a technique revisited.
    Farooq A; Agarwal S; Jones V
    Cardiovasc Intervent Radiol; 2013 Jun; 36(3):820-3. PubMed ID: 23443251
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Twinkling artifact in small animal color-Doppler sonography.
    Louvet A
    Vet Radiol Ultrasound; 2006; 47(4):384-90. PubMed ID: 16863058
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Twinkling artifact on color Doppler sonography: dependence on machine parameters and underlying cause.
    Kamaya A; Tuthill T; Rubin JM
    AJR Am J Roentgenol; 2003 Jan; 180(1):215-22. PubMed ID: 12490508
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Evaluation of Stone Features That Cause the Color Doppler Ultrasound Twinkling Artifact.
    Rokni E; Zinck S; Simon JC
    Ultrasound Med Biol; 2021 May; 47(5):1310-1318. PubMed ID: 33602553
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Noninvasive Prediction of Renal Stone Surface Irregularities by Numerical Analysis of the Color Doppler Twinkling Artifact: An Ex Vivo Study.
    Jamzad A; Setarehdan SK
    J Ultrasound Med; 2018 May; 37(5):1211-1224. PubMed ID: 29086450
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The sonographic twinkling artifact in testicular calcification.
    O'Flynn EA; Sidhu PS
    J Ultrasound Med; 2009 Apr; 28(4):515-7. PubMed ID: 19321679
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Detection of encrusted indwelling ureteral stents using a twinkling artifact revealed on color Doppler sonography.
    Trillaud H; Pariente JL; Rabie A; Grenier N
    AJR Am J Roentgenol; 2001 Jun; 176(6):1446-8. PubMed ID: 11373211
    [No Abstract]   [Full Text] [Related]  

  • 19. Assessment of catheter placement and patency by color Doppler ultrasonography.
    Gerscovich EO; Budenz RW; Lengle SJ
    J Ultrasound Med; 1994 May; 13(5):367-70. PubMed ID: 8015043
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Percutaneous nephrostomy catheters: drainage flow and retention strength.
    Canales BK; Hendlin K; Braasch M; Antolak C; Reddy A; Odeh B; Monga M
    Urology; 2005 Aug; 66(2):261-5. PubMed ID: 16040088
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.