330 related articles for article (PubMed ID: 22323694)
21. Biomechanical comparison of distal femoral fracture fixation: Polyaxial vs. uniaxial locking screws with different blocking screw configurations in retrograde femoral nailing.
Batar S; Söylemez MS; Bozdağ SE; Yaman E; Kemah B; Poyanlı OS
Orthop Traumatol Surg Res; 2024 Feb; 110(1):103695. PubMed ID: 37783426
[TBL] [Abstract][Full Text] [Related]
22. Locked plating of comminuted distal femur fractures: does unlocked screw placement affect stability and failure?
Cui S; Bledsoe JG; Israel H; Watson JT; Cannada LK
J Orthop Trauma; 2014 Feb; 28(2):90-6. PubMed ID: 23860132
[TBL] [Abstract][Full Text] [Related]
23. Biomechanical considerations in plate osteosynthesis: the effect of plate-to-bone compression with and without angular screw stability.
Stoffel K; Lorenz KU; Kuster MS
J Orthop Trauma; 2007 Jul; 21(6):362-8. PubMed ID: 17620993
[TBL] [Abstract][Full Text] [Related]
24. A biomechanical comparison of locked plate fixation with percutaneous insertion capability versus the angled blade plate in a subtrochanteric fracture gap model.
Crist BD; Khalafi A; Hazelwood SJ; Lee MA
J Orthop Trauma; 2009 Oct; 23(9):622-7. PubMed ID: 19897982
[TBL] [Abstract][Full Text] [Related]
25. Internal fixation of type-C distal femoral fractures in osteoporotic bone.
Wähnert D; Hoffmeier KL; von Oldenburg G; Fröber R; Hofmann GO; Mückley T
J Bone Joint Surg Am; 2010 Jun; 92(6):1442-52. PubMed ID: 20516320
[TBL] [Abstract][Full Text] [Related]
26. Influence of an additional locking screw on fracture reduction after volar fixed-angle plating-introduction of the "protection screw" in an extra-articular distal radius fracture model.
Weninger P; Schueller M; Drobetz H; Jamek M; Redl H; Tschegg E
J Trauma; 2009 Oct; 67(4):746-51. PubMed ID: 19820581
[TBL] [Abstract][Full Text] [Related]
27. The mechanical stability of extra-articular distal radius fractures with respect to the number of screws securing the distal fragment.
Crosby SN; Fletcher ND; Yap ER; Lee DH
J Hand Surg Am; 2013 Jun; 38(6):1097-105. PubMed ID: 23707009
[TBL] [Abstract][Full Text] [Related]
28. Locking plates increase the strength of dynamic hip screws.
Jewell DP; Gheduzzi S; Mitchell MS; Miles AW
Injury; 2008 Feb; 39(2):209-12. PubMed ID: 17880976
[TBL] [Abstract][Full Text] [Related]
29. Fixation of extra-articular distal humerus fractures using one locking plate versus two reconstruction plates: a laboratory study.
Tejwani NC; Murthy A; Park J; McLaurin TM; Egol KA; Kummer FJ
J Trauma; 2009 Mar; 66(3):795-9. PubMed ID: 19276755
[TBL] [Abstract][Full Text] [Related]
30. Proximal Screw Configuration Alters Peak Plate Strain Without Changing Construct Stiffness in Comminuted Supracondylar Femur Fractures.
McLachlin S; Kreder H; Ng M; Jenkinson R; Whyne C; Larouche J
J Orthop Trauma; 2017 Dec; 31(12):e418-e424. PubMed ID: 28902085
[TBL] [Abstract][Full Text] [Related]
31. A three-dimensional comparison of intramedullary nail constructs for osteopenic supracondylar femur fractures.
Paller DJ; Frenzen SW; Bartlett CS; Beardsley CL; Beynnon BD
J Orthop Trauma; 2013 Feb; 27(2):93-9. PubMed ID: 22534687
[TBL] [Abstract][Full Text] [Related]
32. Can locking screws allow smaller, low-profile plates to achieve comparable stability to larger, standard plates?
Garrigues GE; Glisson RR; Garrigues NW; Richard MJ; Ruch DS
J Orthop Trauma; 2011 Jun; 25(6):347-54. PubMed ID: 21577070
[TBL] [Abstract][Full Text] [Related]
33. Vertically oriented femoral neck fractures: mechanical analysis of four fixation techniques.
Aminian A; Gao F; Fedoriw WW; Zhang LQ; Kalainov DM; Merk BR
J Orthop Trauma; 2007 Sep; 21(8):544-8. PubMed ID: 17805021
[TBL] [Abstract][Full Text] [Related]
34. Supracondylar femur fracture fixation: mechanical comparison of the 95 degrees condylar side plate and screw versus 95 degrees angled blade plate.
Jaakkola JI; Lundy DW; Moore T; Jones B; Ganey TM; Hutton WC
Acta Orthop Scand; 2002 Jan; 73(1):72-6. PubMed ID: 11928916
[TBL] [Abstract][Full Text] [Related]
35. Biomechanical comparison of bicortical locking versus unicortical far-cortex-abutting locking screw-plate fixation for comminuted radial shaft fractures.
Overturf SJ; Morris RP; Gugala Z; Lindsey RW
J Hand Surg Am; 2014 Oct; 39(10):1907-13. PubMed ID: 25149898
[TBL] [Abstract][Full Text] [Related]
36. Does a volar locking plate provide equivalent stability as a dorsal nonlocking plate in a dorsally comminuted distal radius fracture?: a biomechanical study.
Kandemir U; Matityahu A; Desai R; Puttlitz C
J Orthop Trauma; 2008 Oct; 22(9):605-10. PubMed ID: 18827589
[TBL] [Abstract][Full Text] [Related]
37. [Osteosynthesis for periprosthetic supracondylar fracture above a total knee arthroplasty using a locking compression plate].
Krbec M; Motycka J; Lunácek L; Dousa P
Acta Chir Orthop Traumatol Cech; 2009 Dec; 76(6):473-8. PubMed ID: 20067694
[TBL] [Abstract][Full Text] [Related]
38. Biomechanical comparison of polyaxial and uniaxial locking plate fixation in a proximal tibial gap model.
Cullen AB; Curtiss S; Lee MA
J Orthop Trauma; 2009 Aug; 23(7):507-13. PubMed ID: 19633460
[TBL] [Abstract][Full Text] [Related]
39. A comparative biomechanical analysis of fixation devices for unstable femoral neck fractures: the Intertan versus cannulated screws or a dynamic hip screw.
Rupprecht M; Grossterlinden L; Ruecker AH; de Oliveira AN; Sellenschloh K; Nüchtern J; Püschel K; Morlock M; Rueger JM; Lehmann W
J Trauma; 2011 Sep; 71(3):625-34. PubMed ID: 21768904
[TBL] [Abstract][Full Text] [Related]
40. Cyclic loading of periprosthetic fracture fixation constructs.
Talbot M; Zdero R; Schemitsch EH
J Trauma; 2008 May; 64(5):1308-12. PubMed ID: 18469655
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]