BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

257 related articles for article (PubMed ID: 22335408)

  • 1. Impact of cutout off axis on electron beam dosimetric parameters.
    Arunkumar T; Supe SS; Ravikumar M; Sathiyan S; Ganesh KM
    Technol Cancer Res Treat; 2012 Apr; 11(2):141-7. PubMed ID: 22335408
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Electron radiotherapy: a study on dosimetric uncertainty using small cutouts.
    Chow JC; Grigorov GN
    Phys Med Biol; 2007 Jan; 52(1):N1-11. PubMed ID: 17183121
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Output calculation of electron therapy at extended SSD using an improved LBR method.
    Alkhatib HA; Gebreamlak WT; Tedeschi DJ; Mihailidis D; Wright BW; Neglia WJ; Sobash PT; Fontenot JD
    Med Phys; 2015 Feb; 42(2):735-40. PubMed ID: 25652487
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dosimetry of small circular fields for 6-MeV electron beams.
    Xu MM; Sethi A; Glasgow GP
    Med Dosim; 2009; 34(1):51-6. PubMed ID: 19181256
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Peripheral dose outside applicators in electron beams.
    Chow JC; Grigorov GN
    Phys Med Biol; 2006 Jun; 51(12):N231-40. PubMed ID: 16757855
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Monte Carlo commissioning of clinical electron beams using large field measurements.
    O'Shea TP; Sawkey DL; Foley MJ; Faddegon BA
    Phys Med Biol; 2010 Jul; 55(14):4083-105. PubMed ID: 20601775
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Characteristics of very high-energy electron beams for the irradiation of deep-seated targets.
    Böhlen TT; Germond JF; Traneus E; Bourhis J; Vozenin MC; Bailat C; Bochud F; Moeckli R
    Med Phys; 2021 Jul; 48(7):3958-3967. PubMed ID: 33884618
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Monte Carlo investigation of electron beam output factors versus size of square cutout.
    Zhang GG; Rogers DW; Cygler JE; Mackie TR
    Med Phys; 1999 May; 26(5):743-50. PubMed ID: 10360536
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of electron beam obliquity on lateral buildup ratio: a Monte Carlo dosimetry evaluation.
    Chow JC; Grigorov GN
    Phys Med Biol; 2007 Jul; 52(13):3965-77. PubMed ID: 17664588
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dosimetric dependence of the dimensional characteristics on a lead shield in electron radiotherapy: a Monte Carlo study.
    Chow JCL; Grigorov GN
    J Appl Clin Med Phys; 2009 Apr; 10(2):75-91. PubMed ID: 19458593
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Monte Carlo study of in-field and out-of-field dose distributions from a linear accelerator operating with and without a flattening-filter.
    Almberg SS; Frengen J; Lindmo T
    Med Phys; 2012 Aug; 39(8):5194-203. PubMed ID: 22894444
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Monte carlo electron source model validation for an Elekta Precise linac.
    Ali OA; Willemse CA; Shaw W; O'Reilly FH; du Plessis FC
    Med Phys; 2011 May; 38(5):2366-73. PubMed ID: 21776771
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The peripheral dose outside the applicator in electron beams of Oncor linear accelerator.
    Iktueren B; Bilge H; Karacam S; Atkovar G
    Radiat Prot Dosimetry; 2012 Jun; 150(2):192-7. PubMed ID: 22025738
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Monte Carlo simulation of beam characteristics from small fields based on TrueBeam flattening-filter-free mode.
    Feng Z; Yue H; Zhang Y; Wu H; Cheng J; Su X
    Radiat Oncol; 2016 Feb; 11():30. PubMed ID: 26921246
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Changes in electron beam dosimetry with a new scattering foil-applicator system on a CL2100C.
    Klein EE; Low DA; Purdy JA
    Int J Radiat Oncol Biol Phys; 1995 May; 32(2):483-90. PubMed ID: 7751189
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The use of an extra-focal electron source to model collimator-scattered electrons using the pencil-beam redefinition algorithm.
    Boyd RA; Hogstrom KR; White RA; Antolak JA
    Med Phys; 2002 Nov; 29(11):2571-83. PubMed ID: 12462724
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Investigation of the Usefulness of Monte Carlo Simulation in Electron Beam Therapy Using Body Surface Lead Cutout].
    Ono N
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2024 Feb; 80(2):175-187. PubMed ID: 38030241
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A Monte Carlo simulation framework for electron beam dose calculations using Varian phase space files for TrueBeam Linacs.
    Rodrigues A; Sawkey D; Yin FF; Wu Q
    Med Phys; 2015 May; 42(5):2389-403. PubMed ID: 25979034
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Convolution-based modified Clarkson integration (CMCI) for electron cutout factor calculation.
    Chang J; Lin MH; Lu W; Chen M; Jiang S
    J Appl Clin Med Phys; 2018 Mar; 19(2):128-136. PubMed ID: 29396894
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Monte Carlo techniques for scattering foil design and dosimetry in total skin electron irradiations.
    Ye SJ; Pareek PN; Spencer S; Duan J; Brezovich IA
    Med Phys; 2005 Jun; 32(6):1460-8. PubMed ID: 16013701
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.