These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

241 related articles for article (PubMed ID: 22337629)

  • 1. Leg stiffness of sprinters using running-specific prostheses.
    McGowan CP; Grabowski AM; McDermott WJ; Herr HM; Kram R
    J R Soc Interface; 2012 Aug; 9(73):1975-82. PubMed ID: 22337629
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Leg stiffness during sprinting in transfemoral amputees with running-specific prosthesis.
    Sano Y; Makimoto A; Hashizume S; Murai A; Kobayashi Y; Takemura H; Hobara H
    Gait Posture; 2017 Jul; 56():65-67. PubMed ID: 28505545
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Leg stiffness in unilateral transfemoral amputees across a range of running speeds.
    Hobara H; Sakata H; Hashizume S; Kobayashi Y
    J Biomech; 2019 Feb; 84():67-72. PubMed ID: 30587378
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Running-specific prostheses limit ground-force during sprinting.
    Grabowski AM; McGowan CP; McDermott WJ; Beale MT; Kram R; Herr HM
    Biol Lett; 2010 Apr; 6(2):201-4. PubMed ID: 19889694
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Regulation of step frequency in transtibial amputee endurance athletes using a running-specific prosthesis.
    Oudenhoven LM; Boes JM; Hak L; Faber GS; Houdijk H
    J Biomech; 2017 Jan; 51():42-48. PubMed ID: 27923481
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Amputee locomotion: spring-like leg behavior and stiffness regulation using running-specific prostheses.
    Hobara H; Baum BS; Kwon HJ; Miller RH; Ogata T; Kim YH; Shim JK
    J Biomech; 2013 Sep; 46(14):2483-9. PubMed ID: 23953671
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Running at submaximal speeds, the role of the intact and prosthetic limbs for trans-tibial amputees.
    Strike SC; Arcone D; Orendurff M
    Gait Posture; 2018 May; 62():327-332. PubMed ID: 29614465
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effects of prosthetic stiffness and added mass on metabolic power and asymmetry in female runners with a leg amputation.
    Ashcraft KR; Grabowski AM
    J Appl Physiol (1985); 2024 Jul; 137(1):85-98. PubMed ID: 38841756
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ground Reaction Forces During Sprinting in Unilateral Transfemoral Amputees.
    Makimoto A; Sano Y; Hashizume S; Murai A; Kobayashi Y; Takemura H; Hobara H
    J Appl Biomech; 2017 Dec; 33(6):406-409. PubMed ID: 28605277
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dynamic elastic response prostheses alter approach angles and ground reaction forces but not leg stiffness during a start-stop task.
    Haber CK; Ritchie LJ; Strike SC
    Hum Mov Sci; 2018 Apr; 58():337-346. PubMed ID: 29269103
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of running speed and leg prostheses on mediolateral foot placement and its variability.
    Arellano CJ; McDermott WJ; Kram R; Grabowski AM
    PLoS One; 2015; 10(1):e0115637. PubMed ID: 25590634
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The biomechanics of the fastest sprinter with a unilateral transtibial amputation.
    Beck ON; Grabowski AM
    J Appl Physiol (1985); 2018 Mar; 124(3):641-645. PubMed ID: 29051334
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Prosthetic model, but not stiffness or height, affects the metabolic cost of running for athletes with unilateral transtibial amputations.
    Beck ON; Taboga P; Grabowski AM
    J Appl Physiol (1985); 2017 Jul; 123(1):38-48. PubMed ID: 28360121
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Maximum-speed curve-running biomechanics of sprinters with and without unilateral leg amputations.
    Taboga P; Kram R; Grabowski AM
    J Exp Biol; 2016 Mar; 219(Pt 6):851-8. PubMed ID: 26985053
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Prosthetic shape, but not stiffness or height, affects the maximum speed of sprinters with bilateral transtibial amputations.
    Taboga P; Beck ON; Grabowski AM
    PLoS One; 2020; 15(2):e0229035. PubMed ID: 32078639
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of step frequency on leg stiffness during running in unilateral transfemoral amputees.
    Hobara H; Sakata H; Namiki Y; Hisano G; Hashizume S; Usui F
    Sci Rep; 2020 Apr; 10(1):5965. PubMed ID: 32249808
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A Limb-specific Strategy across a Range of Running Speeds in Transfemoral Amputees.
    Sakata H; Hashizume S; Takemura H; Hobara H
    Med Sci Sports Exerc; 2020 Apr; 52(4):892-899. PubMed ID: 31688651
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Spring-mass behavioural adaptations to acute changes in prosthetic blade stiffness during submaximal running in unilateral transtibial prosthesis users.
    Barnett CT; De Asha AR; Skervin TK; Buckley JG; Foster RJ
    Gait Posture; 2022 Oct; 98():153-159. PubMed ID: 36126535
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Reduced prosthetic stiffness lowers the metabolic cost of running for athletes with bilateral transtibial amputations.
    Beck ON; Taboga P; Grabowski AM
    J Appl Physiol (1985); 2017 Apr; 122(4):976-984. PubMed ID: 28104752
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Anterior-posterior ground reaction forces across a range of running speeds in unilateral transfemoral amputees.
    Sakata H; Hashizume S; Amma R; Hisano G; Murata H; Takemura H; Usui F; Hobara H
    Sports Biomech; 2024 Jan; 23(1):69-80. PubMed ID: 33112726
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.