These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

489 related articles for article (PubMed ID: 22342696)

  • 41. Selective and sensitive determination of dopamine by composites of polypyrrole and graphene modified electrodes.
    Si P; Chen H; Kannan P; Kim DH
    Analyst; 2011 Dec; 136(24):5134-8. PubMed ID: 22010122
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Electrochemical sensor based on an electrode modified with porous graphitic carbon nitride nanosheets (C
    Zhang L; Liu C; Wang Q; Wang X; Wang S
    Mikrochim Acta; 2020 Jan; 187(2):149. PubMed ID: 31989275
    [TBL] [Abstract][Full Text] [Related]  

  • 43. N-Doped Reduced Graphene Oxide/Gold Nanoparticles Composite as an Improved Sensing Platform for Simultaneous Detection of Dopamine, Ascorbic Acid, and Uric Acid.
    Minta D; González Z; Wiench P; Gryglewicz S; Gryglewicz G
    Sensors (Basel); 2020 Aug; 20(16):. PubMed ID: 32784787
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Simultaneous electrochemical determination of uric acid, dopamine, and ascorbic acid at single-walled carbon nanohorn modified glassy carbon electrode.
    Zhu S; Li H; Niu W; Xu G
    Biosens Bioelectron; 2009 Dec; 25(4):940-3. PubMed ID: 19733474
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Au/ZnO hybrid nanocatalysts impregnated in N-doped graphene for simultaneous determination of ascorbic acid, acetaminophen and dopamine.
    Chen X; Zhang G; Shi L; Pan S; Liu W; Pan H
    Mater Sci Eng C Mater Biol Appl; 2016 Aug; 65():80-9. PubMed ID: 27157730
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Indium tin oxide-coated glass modified with reduced graphene oxide sheets and gold nanoparticles as disposable working electrodes for dopamine sensing in meat samples.
    Yang J; Strickler JR; Gunasekaran S
    Nanoscale; 2012 Aug; 4(15):4594-602. PubMed ID: 22706569
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Catalyst-free synthesis of nitrogen-doped graphene via thermal annealing graphite oxide with melamine and its excellent electrocatalysis.
    Sheng ZH; Shao L; Chen JJ; Bao WJ; Wang FB; Xia XH
    ACS Nano; 2011 Jun; 5(6):4350-8. PubMed ID: 21574601
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Electrochemical detection of dopamine in the presence of ascorbic acid using PVP/graphene modified electrodes.
    Liu Q; Zhu X; Huo Z; He X; Liang Y; Xu M
    Talanta; 2012 Aug; 97():557-62. PubMed ID: 22841122
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Defects regulating of graphene ink for electrochemical determination of ascorbic acid, dopamine and uric acid.
    Fu L; Wang A; Lai G; Su W; Malherbe F; Yu J; Lin CT; Yu A
    Talanta; 2018 Apr; 180():248-253. PubMed ID: 29332806
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Facile synthesis of graphene hybrid tube-like structure for simultaneous detection of ascorbic acid, dopamine, uric acid and tryptophan.
    Zhang W; Chai Y; Yuan R; Chen S; Han J; Yuan D
    Anal Chim Acta; 2012 Dec; 756():7-12. PubMed ID: 23176734
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Holey nitrogen-doped graphene aerogel for simultaneously electrochemical determination of ascorbic acid, dopamine and uric acid.
    Feng S; Yu L; Yan M; Ye J; Huang J; Yang X
    Talanta; 2021 Mar; 224():121851. PubMed ID: 33379067
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Simultaneous and sensitive determination of ascorbic acid, dopamine, uric acid, and tryptophan with silver nanoparticles-decorated reduced graphene oxide modified electrode.
    Kaur B; Pandiyan T; Satpati B; Srivastava R
    Colloids Surf B Biointerfaces; 2013 Nov; 111():97-106. PubMed ID: 23777794
    [TBL] [Abstract][Full Text] [Related]  

  • 53. In situ electrochemical synthesis of highly loaded zirconium nanoparticles decorated reduced graphene oxide for the selective determination of dopamine and paracetamol in presence of ascorbic acid.
    Ezhil Vilian AT; Rajkumar M; Chen SM
    Colloids Surf B Biointerfaces; 2014 Mar; 115():295-301. PubMed ID: 24384145
    [TBL] [Abstract][Full Text] [Related]  

  • 54. The comparison of different gold nanoparticles/graphene nanosheets hybrid nanocomposites in electrochemical performance and the construction of a sensitive uric acid electrochemical sensor with novel hybrid nanocomposites.
    Xue Y; Zhao H; Wu Z; Li X; He Y; Yuan Z
    Biosens Bioelectron; 2011 Nov; 29(1):102-8. PubMed ID: 21871789
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Novel electrochemical sensor based on N-doped carbon nanotubes and Fe3O4 nanoparticles: simultaneous voltammetric determination of ascorbic acid, dopamine and uric acid.
    Fernandes DM; Costa M; Pereira C; Bachiller-Baeza B; Rodríguez-Ramos I; Guerrero-Ruiz A; Freire C
    J Colloid Interface Sci; 2014 Oct; 432():207-13. PubMed ID: 25086716
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Multi-walled carbon nanotube modified carbon paste electrode as an electrochemical sensor for the determination of epinephrine in the presence of ascorbic acid and uric acid.
    Thomas T; Mascarenhas RJ; Martis P; Mekhalif Z; Swamy BE
    Mater Sci Eng C Mater Biol Appl; 2013 Aug; 33(6):3294-302. PubMed ID: 23706213
    [TBL] [Abstract][Full Text] [Related]  

  • 57. The facile and simple synthesis of poly(3,4ethylenedioxythiophene) anchored reduced graphene oxide nanocomposite for biochemical analysis.
    Dinesh B; Vilian ATE; Kwak CH; Huh YS; Saraswathi R; Han YK
    Anal Chim Acta; 2019 Oct; 1077():150-159. PubMed ID: 31307704
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Synthesis of short graphene oxide nanoribbons for improved biomarker detection of Parkinson's disease.
    Sun CL; Su CH; Wu JJ
    Biosens Bioelectron; 2015 May; 67():327-33. PubMed ID: 25201013
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Enhanced sensing of dopamine in the present of ascorbic acid based on graphene/poly(p-aminobenzoic acid) composite film.
    Huang KJ; Jing QS; Wu ZW; Wang L; Wei CY
    Colloids Surf B Biointerfaces; 2011 Nov; 88(1):310-4. PubMed ID: 21798724
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Electrochemical sensing and biosensing platform based on chemically reduced graphene oxide.
    Zhou M; Zhai Y; Dong S
    Anal Chem; 2009 Jul; 81(14):5603-13. PubMed ID: 19522529
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 25.