These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
200 related articles for article (PubMed ID: 22346617)
21. Determination of hydroxyurea in capsules and biological fluids by ion-selective potentiometry and fluorimetry. El-Kosasy AM J AOAC Int; 2003; 86(1):15-21. PubMed ID: 12607735 [TBL] [Abstract][Full Text] [Related]
22. Ionophore-Based Polymeric Sensors for Potentiometric Assay of the Anticancer Drug Gemcitabine in Pharmaceutical Formulation: A Comparative Study. Mostafa GAE; El-Tohamy MF; Ali EA; Al-Salahi R; Attwa MW; AlRabiah H Molecules; 2023 Nov; 28(22):. PubMed ID: 38005274 [TBL] [Abstract][Full Text] [Related]
23. Tetracycline-selective electrode for content determination and dissolution studies of pharmaceuticals by flow-injection analysis (FIA). Sales MG; Montenegro MC J Pharm Sci; 2001 Aug; 90(8):1125-33. PubMed ID: 11536217 [TBL] [Abstract][Full Text] [Related]
24. A Novel Polymeric Membrane Sensor for Chlorhexidine Determination. Lenik J; Sokal K Sensors (Basel); 2023 Nov; 23(23):. PubMed ID: 38067881 [TBL] [Abstract][Full Text] [Related]
25. Flow injection potentiometric determination of pancuronium bromide in pharmaceutical preparation and urine samples using modified carbon paste electrodes. Zayed SI Chem Pharm Bull (Tokyo); 2011; 59(2):254-9. PubMed ID: 21297308 [TBL] [Abstract][Full Text] [Related]
26. Combinatorial screening of potentiometric Pb(II) sensors from polysulfoaminoanthraquinone solid ionophore. Huang MR; Ding YB; Li XG ACS Comb Sci; 2014 Mar; 16(3):128-38. PubMed ID: 24512280 [TBL] [Abstract][Full Text] [Related]
27. Chloride-selective membrane electrodes and optodes based on an indium(III) porphyrin for the determination of chloride in a sequential injection analysis system. Pimenta AM; Araújo AN; Montenegro MC; Pasquini C; Rohwedder JJ; Raimundo IM J Pharm Biomed Anal; 2004 Sep; 36(1):49-55. PubMed ID: 15351047 [TBL] [Abstract][Full Text] [Related]
28. Potentiometric determination of mebeverine hydrochloride antispasmodic drug based on molecular docking with different ionophores host-guest inclusion as a theoretical study. Abdel-Raoof AM; Fouad MM; Rashed NS; Hosni NYZ; Elsonbaty A; Abdel-Fattah A RSC Adv; 2023 Jan; 13(2):1085-1093. PubMed ID: 36686904 [TBL] [Abstract][Full Text] [Related]
29. Flow-through chloroquine sensor and its applications in pharmaceutical analysis. Saad B; Zin ZM; Jab MS; Rahman IA; Saleh MI; Mahsufi S Anal Sci; 2005 May; 21(5):521-4. PubMed ID: 15913140 [TBL] [Abstract][Full Text] [Related]
30. A new potentiometric electrode incorporating functionalized β-cyclodextrins for diclofenac determination. Lenik J Mater Sci Eng C Mater Biol Appl; 2014 Dec; 45():109-16. PubMed ID: 25491808 [TBL] [Abstract][Full Text] [Related]
31. Polyvinyl Chloride Modified Carbon Paste Electrodes for Sensitive Determination of Levofloxacin Drug in Serum, Urine, and Pharmaceutical Formulations. Abdel-Haleem FM; Mahmoud S; Abdel-Ghani NET; El Nashar RM; Bechelany M; Barhoum A Sensors (Basel); 2021 May; 21(9):. PubMed ID: 34062895 [TBL] [Abstract][Full Text] [Related]
33. Development of the New Sensor Based on Functionalized Carbon Nanomaterials for Promethazine Hydrochloride Determination. Samardžić M; Peršić M; Széchenyi A; Jozanović M; Pukleš I; Budetić M Sensors (Basel); 2023 Feb; 23(5):. PubMed ID: 36904844 [TBL] [Abstract][Full Text] [Related]
34. New potentiometric sensors for methylphenidate detection based on host-guest interaction. AlRabiah H; Abounassif M; Aljohar HI; Mostafa GA BMC Chem; 2019 Dec; 13(1):121. PubMed ID: 31637370 [TBL] [Abstract][Full Text] [Related]
35. Polymeric Membrane Electrodes Using Calix[4]pyrrole Bis/Tetra-Phosphonate Cavitands as Ionophores for Potentiometric Acetylcholine Sensing with High Selectivity. Li L; Zhang Y; Du P; Qian Y; Zhang P; Guo Q Anal Chem; 2020 Nov; 92(21):14740-14746. PubMed ID: 33064457 [TBL] [Abstract][Full Text] [Related]
36. Fabrication of a highly selective cadmium (II) sensor based on 1,13-bis(8-quinolyl)-1,4,7,10,13-pentaoxatridecane as a supramolecular ionophore. Ghaemi A; Tavakkoli H; Mombeni T Mater Sci Eng C Mater Biol Appl; 2014 May; 38():186-91. PubMed ID: 24656367 [TBL] [Abstract][Full Text] [Related]
37. Novel potentiometric application for the determination of pantoprazole sodium and itopride hydrochloride in their pure and combined dosage form. Ragab MT; Abd El-Rahman MK; Ramadan NK; El-Ragehy NA; El-Zeany BA Talanta; 2015 Jun; 138():28-35. PubMed ID: 25863367 [TBL] [Abstract][Full Text] [Related]
38. Electroanalytical performance of a terbium(III)-selective sensor based on a neutral ionophore in environmental and medicinal samples. Gupta VK; Singh AK; Gupta B Anal Bioanal Chem; 2008 Apr; 390(8):2171-81. PubMed ID: 18335212 [TBL] [Abstract][Full Text] [Related]
39. A novel poly(vinyl chloride) matrix membrane sensor for batch and flow-injection determinations of thiocyanate, cyanide and some metal ions. Hassan SS; Badr IH; Kamel AH; Mohamed MS Anal Sci; 2009 Jul; 25(7):911-7. PubMed ID: 19609032 [TBL] [Abstract][Full Text] [Related]
40. Potentiometric sensors enabling fast screening of the benign prostatic hyperplasia drug alfuzosin in pharmaceuticals, urine and serum. Gupta VK; Singh AK; Gupta B Comb Chem High Throughput Screen; 2007 Aug; 10(7):560-70. PubMed ID: 17979639 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]