230 related articles for article (PubMed ID: 22349327)
1. Development of a liquid chromatography-tandem mass spectrometry method for plasma-free metanephrines with ion-pairing turbulent flow online extraction.
He X; Kozak M
Anal Bioanal Chem; 2012 Mar; 402(9):3003-10. PubMed ID: 22349327
[TBL] [Abstract][Full Text] [Related]
2. Quantitative measurement of plasma free metanephrines by ion-pairing solid phase extraction and liquid chromatography-tandem mass spectrometry with porous graphitic carbon column.
He X; Gabler J; Yuan C; Wang S; Shi Y; Kozak M
J Chromatogr B Analyt Technol Biomed Life Sci; 2011 Aug; 879(23):2355-9. PubMed ID: 21723209
[TBL] [Abstract][Full Text] [Related]
3. Quantitation of Free Metanephrines in Plasma by Liquid Chromatography-Tandem Mass Spectrometry.
Heideloff C; Payto D; Wang S
Methods Mol Biol; 2016; 1378():139-47. PubMed ID: 26602126
[TBL] [Abstract][Full Text] [Related]
4. Quantification of Metanephrine and Normetanephrine in Urine Using Liquid Chromatography-Tandem Mass Spectrometry.
Gabler J; Wang S
Methods Mol Biol; 2016; 1378():149-57. PubMed ID: 26602127
[TBL] [Abstract][Full Text] [Related]
5. A novel method for the measurement of plasma metanephrines using online solid phase extraction-liquid chromatography tandem mass spectrometry.
Adaway JE; Peitzsch M; Keevil BG
Ann Clin Biochem; 2015 May; 52(Pt 3):361-9. PubMed ID: 25047871
[TBL] [Abstract][Full Text] [Related]
6. A simple liquid chromatography-tandem mass spectrometry method for measuring metanephrine and normetanephrine in urine.
Gabler J; Miller A; Wang S
Clin Chem Lab Med; 2011 Jul; 49(7):1213-6. PubMed ID: 21574886
[TBL] [Abstract][Full Text] [Related]
7. Development and validation of liquid chromatography-tandem mass spectrometry method for quantification of plasma metanephrines for differential diagnosis of adrenal incidentaloma.
Lee SM; Lee MN; Oh HJ; Cho YY; Kim JH; Woo HI; Park HD; Lee SY
Ann Lab Med; 2015 Sep; 35(5):519-22. PubMed ID: 26206689
[TBL] [Abstract][Full Text] [Related]
8. A simple and rapid analytical method based on solid-phase extraction and liquid chromatography-tandem mass spectrometry for the simultaneous determination of free catecholamines and metanephrines in urine and its application to routine clinical analysis.
Woo HI; Yang JS; Oh HJ; Cho YY; Kim JH; Park HD; Lee SY
Clin Biochem; 2016 May; 49(7-8):573-9. PubMed ID: 26779993
[TBL] [Abstract][Full Text] [Related]
9. Matrix interference in LC-ESI-MS/MS analysis of metanephrines in protein precipitated plasma samples.
Rebane R; Herodes K
Eur J Mass Spectrom (Chichester); 2020 Feb; 26(1):46-54. PubMed ID: 31288535
[TBL] [Abstract][Full Text] [Related]
10. Urinary metanephrines by liquid chromatography tandem mass spectrometry: using multiple quantification methods to minimize interferences in a high throughput method.
Clark ZD; Frank EL
J Chromatogr B Analyt Technol Biomed Life Sci; 2011 Dec; 879(31):3673-80. PubMed ID: 22036658
[TBL] [Abstract][Full Text] [Related]
11. Isopropanol protein precipitation for the analysis of plasma free metanephrines by liquid chromatography-tandem mass spectrometry.
Marney LC; Laha TJ; Baird GS; Rainey PM; Hoofnagle AN
Clin Chem; 2008 Oct; 54(10):1729-32. PubMed ID: 18687739
[TBL] [Abstract][Full Text] [Related]
12. Plasma free metanephrine measurement using automated online solid-phase extraction HPLC tandem mass spectrometry.
de Jong WH; Graham KS; van der Molen JC; Links TP; Morris MR; Ross HA; de Vries EG; Kema IP
Clin Chem; 2007 Sep; 53(9):1684-93. PubMed ID: 17712005
[TBL] [Abstract][Full Text] [Related]
13. Improved plasma free metadrenaline analysis requires mixed mode cation exchange solid-phase extraction prior to liquid chromatography tandem mass spectrometry detection.
Clarke MW; Cooke B; Hoad K; Glendenning P
Ann Clin Biochem; 2011 Jul; 48(Pt 4):352-7. PubMed ID: 21690275
[TBL] [Abstract][Full Text] [Related]
14. Simultaneous measurement of urinary metanephrines and catecholamines by liquid chromatography with tandem mass spectrometric detection.
Whiting MJ
Ann Clin Biochem; 2009 Mar; 46(Pt 2):129-36. PubMed ID: 19176643
[TBL] [Abstract][Full Text] [Related]
15. Performance of plasma free metanephrines measured by liquid chromatography-tandem mass spectrometry in the diagnosis of pheochromocytoma.
Peaston RT; Graham KS; Chambers E; van der Molen JC; Ball S
Clin Chim Acta; 2010 Apr; 411(7-8):546-52. PubMed ID: 20083099
[TBL] [Abstract][Full Text] [Related]
16. Determination of N-nitrosodiethanolamine, NDELA in cosmetic ingredients and products by mixed mode solid phase extraction and UPLC-tandem mass spectrometry with porous graphitic carbon column through systemic sample pre-cleanup procedure.
Joo KM; Shin MS; Jung JH; Kim BM; Lee JW; Jeong HJ; Lim KM
Talanta; 2015 May; 137():109-19. PubMed ID: 25770613
[TBL] [Abstract][Full Text] [Related]
17. Multiple reaction monitoring with multistage fragmentation (MRM3) detection enhances selectivity for LC-MS/MS analysis of plasma free metanephrines.
Wright MJ; Thomas RL; Stanford PE; Horvath AR
Clin Chem; 2015 Mar; 61(3):505-13. PubMed ID: 25605684
[TBL] [Abstract][Full Text] [Related]
18. [Determination of urine catecholamines and metanephrines by reversed-phase liquid chromatography-tandem mass spectrometry].
Cheuk MY; Lo YC; Poon WT
Se Pu; 2017 Oct; 35(10):1042-1047. PubMed ID: 29048800
[TBL] [Abstract][Full Text] [Related]
19. Validation of an improved liquid chromatography tandem mass spectrometry method for rapid and simultaneous analysis of plasma catecholamine and their metabolites.
Yu S; Yin Y; Li Q; Yu J; Liu W; Wang D; Cheng Q; Xie S; Cheng X; Qiu L
J Chromatogr B Analyt Technol Biomed Life Sci; 2019 Oct; 1129():121805. PubMed ID: 31670057
[TBL] [Abstract][Full Text] [Related]
20. Determination of free and conjugated normetanephrine and metanephrine in human plasma by high-performance liquid chromatography with electrochemical detection.
Pagliari R; Cottet-Emard JM; Peyrin L
J Chromatogr; 1991 Jan; 563(1):23-36. PubMed ID: 2061394
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]