These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 22353906)

  • 1. [Fracture analyses of casting framework removable partial dentures].
    Zhu YH; Zhang B; Liu YH; Qin F; Li HF; Zheng YF
    Beijing Da Xue Xue Bao Yi Xue Ban; 2012 Feb; 44(1):80-3. PubMed ID: 22353906
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparative study of circumferential clasp retention force for titanium and cobalt-chromium removable partial dentures.
    Rodrigues RC; Ribeiro RF; de Mattos Mda G; Bezzon OL
    J Prosthet Dent; 2002 Sep; 88(3):290-6. PubMed ID: 12426499
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Titanium for removable partial dentures (III): 2-year clinical follow-up in an undergraduate programme.
    Au AR; Lechner SK; Thomas CJ; Mori T; Chung P
    J Oral Rehabil; 2000 Nov; 27(11):979-85. PubMed ID: 11106989
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Fatigue resistance of cast occlusal rests using Co-Cr and Ag-Pd-Cu-Au alloys.
    Gapido CG; Kobayashi H; Miyakawa O; Kohno S
    J Prosthet Dent; 2003 Sep; 90(3):261-9. PubMed ID: 12942060
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Titanium for removable dentures. I. Laboratory procedures.
    Mori T; Togaya T; Jean-Louis M; Yabugami M
    J Oral Rehabil; 1997 May; 24(5):338-41. PubMed ID: 9183026
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Deformation properties of Ti-6A1-7Nb alloy castings for removable partial denture frameworks.
    Srimaneepong V; Yoneyama T; Wakabayashi N; Kobayashi E; Hanawa T; Doi H
    Dent Mater J; 2004 Dec; 23(4):497-503. PubMed ID: 15688710
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Titanium for removable dentures. II. Two-year clinical observations.
    Thomas CJ; Lechner S; Mori T
    J Oral Rehabil; 1997 Jun; 24(6):414-8. PubMed ID: 9219984
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cobalt-chromium-titanium alloy for removable partial dentures.
    Iwama CY; Preston JD
    Int J Prosthodont; 1997; 10(4):309-17. PubMed ID: 9484040
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Titanium-alloy vs. CoCr-alloy in removable partial dentures--a clinical study].
    Katsoulis J; Fischer J; Huber S; Balmer S; Mericske-Stern R
    Schweiz Monatsschr Zahnmed; 2008; 118(11):1040-6. PubMed ID: 19066155
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [A preliminary study on the forming quality of titanium alloy removable partial denture frameworks fabricated by selective laser melting].
    Liu YF; Yu H; Wang WN; Gao B
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2017 Jun; 52(6):351-354. PubMed ID: 28613056
    [No Abstract]   [Full Text] [Related]  

  • 11. [Clinical evaluation of denture made of pure titanium].
    Yang X; Tan JG; Li DL; Zhou JF; Chen L
    Beijing Da Xue Xue Bao Yi Xue Ban; 2010 Feb; 42(1):60-2. PubMed ID: 20140045
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of two heat treatments on mechanical properties of selective-laser-melted Co-Cr metal-ceramic alloys for application in thin removable partial dentures.
    Yan X; Lin H; Wu Y; Bai W
    J Prosthet Dent; 2018 Jun; 119(6):1028.e1-1028.e6. PubMed ID: 29980269
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [A study of tarnish induced by Streptococcus sobrinus serotype g on Co-Cr, Ni-Cr and casting titanium alloys].
    Song Y; Xu J; Ma X
    Hua Xi Kou Qiang Yi Xue Za Zhi; 2002 Feb; 20(1):14-7. PubMed ID: 12593192
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of castability and surface roughness of commercially pure titanium and cobalt-chromium denture frameworks.
    Jang KS; Youn SJ; Kim YS
    J Prosthet Dent; 2001 Jul; 86(1):93-8. PubMed ID: 11458267
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparative study of two commercially pure titanium casting methods.
    Rodrigues RC; Faria AC; Orsi IA; Mattos Mda G; Macedo AP; Ribeiro RF
    J Appl Oral Sci; 2010; 18(5):487-92. PubMed ID: 21085805
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Bending properties of strengthened Ti-6Al-7Nb alloy major connectors compared to Co-Cr alloy major connectors.
    Aridome K; Yamazaki M; Baba K; Ohyama T
    J Prosthet Dent; 2005 Mar; 93(3):267-73. PubMed ID: 15775928
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Trueness of removable partial denture frameworks additively manufactured with selective laser melting.
    Peng PW; Hsu CY; Huang HY; Chao JC; Lee WF
    J Prosthet Dent; 2022 Jan; 127(1):122-127. PubMed ID: 33223197
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of metal ion release from Ti6Al4V and Co-Cr-Mo casting alloys: in vivo and in vitro study.
    El Sawy AA; Shaarawy MA
    J Prosthodont; 2014 Feb; 23(2):89-97. PubMed ID: 23755902
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Effects of 3 kinds of processing techniques on the fitness of metal clasp.
    Yin X; Zhou H; Yan F; Wu X; Wu G; Pang D
    Zhong Nan Da Xue Xue Bao Yi Xue Ban; 2021 Oct; 46(10):1122-1128. PubMed ID: 34911843
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Over-refractory casting technique as an alternative to one-piece multi-unit fixed partial denture frameworks.
    de Oliveira Correa G; Henriques GE; Mesquita MF; Sobrinho LC
    J Prosthet Dent; 2006 Mar; 95(3):243-8. PubMed ID: 16543023
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.