These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

78 related articles for article (PubMed ID: 22354255)

  • 1. The "gray zone approach": assessing the accuracy of pulse pressure variation without considering the prevalence?
    Wyffels PA; Wouters PF
    Anesthesiology; 2012 Mar; 116(3):740-1; author reply 741-3. PubMed ID: 22354255
    [No Abstract]   [Full Text] [Related]  

  • 2. Assessing the diagnostic accuracy of pulse pressure variations for the prediction of fluid responsiveness: a "gray zone" approach.
    Cannesson M; Le Manach Y; Hofer CK; Goarin JP; Lehot JJ; Vallet B; Tavernier B
    Anesthesiology; 2011 Aug; 115(2):231-41. PubMed ID: 21705869
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Why the gray zone may shift within the fog.
    Bloomstone JA; Raghunathan K; McGee WT
    Anesthesiology; 2012 Mar; 116(3):739-40; author reply 741-3. PubMed ID: 22354253
    [No Abstract]   [Full Text] [Related]  

  • 4. Assessment of fluid responsiveness: insights in a "gray zone".
    De Hert SG
    Anesthesiology; 2011 Aug; 115(2):229-30. PubMed ID: 21691194
    [No Abstract]   [Full Text] [Related]  

  • 5. Clinical relevance of pulse pressure variations for predicting fluid responsiveness in mechanically ventilated intensive care unit patients: the grey zone approach.
    Biais M; Ehrmann S; Mari A; Conte B; Mahjoub Y; Desebbe O; Pottecher J; Lakhal K; Benzekri-Lefevre D; Molinari N; Boulain T; Lefrant JY; Muller L;
    Crit Care; 2014 Nov; 18(6):587. PubMed ID: 25658489
    [TBL] [Abstract][Full Text] [Related]  

  • 6. How accurate is pulse pressure variation as a predictor of fluid responsiveness?
    Verniquet A; Kakel R
    Anesthesiology; 2012 Mar; 116(3):740; author reply 741-3. PubMed ID: 22354254
    [No Abstract]   [Full Text] [Related]  

  • 7. Pulse Pressure Variation Adjusted by Respiratory Changes in Pleural Pressure, Rather Than by Tidal Volume, Reliably Predicts Fluid Responsiveness in Patients With Acute Respiratory Distress Syndrome.
    Liu Y; Wei LQ; Li GQ; Yu X; Li GF; Li YM
    Crit Care Med; 2016 Feb; 44(2):342-51. PubMed ID: 26457754
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Applicability of pulse pressure variation: how many shades of grey?
    Michard F; Chemla D; Teboul JL
    Crit Care; 2015 Mar; 19(1):144. PubMed ID: 25887325
    [No Abstract]   [Full Text] [Related]  

  • 9. The pitfall of pulse pressure variation in the cardiac dysfunction condition.
    He HW; Liu DW
    Crit Care; 2015 Jun; 19(1):242. PubMed ID: 26058999
    [No Abstract]   [Full Text] [Related]  

  • 10. Pulse oximeter as a sensor of fluid responsiveness: do we have our finger on the best solution?
    Monnet X; Lamia B; Teboul JL
    Crit Care; 2005 Oct; 9(5):429-30. PubMed ID: 16277729
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Pulse pressure variation to predict fluid responsiveness in spontaneously breathing patients: tidal vs. forced inspiratory breathing.
    Hong DM; Lee JM; Seo JH; Min JJ; Jeon Y; Bahk JH
    Anaesthesia; 2014 Jul; 69(7):717-22. PubMed ID: 24773446
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Pulse pressure variation as a predictor of fluid responsiveness during one-lung ventilation for lung surgery using thoracotomy: randomised controlled study.
    Lee JH; Jeon Y; Bahk JH; Gil NS; Hong DM; Kim JH; Kim HJ
    Eur J Anaesthesiol; 2011 Jan; 28(1):39-44. PubMed ID: 21088596
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature.
    Marik PE; Cavallazzi R; Vasu T; Hirani A
    Crit Care Med; 2009 Sep; 37(9):2642-7. PubMed ID: 19602972
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Pulse pressure variation predicts fluid responsiveness in elderly patients after coronary artery bypass graft surgery.
    Yazigi A; Khoury E; Hlais S; Madi-Jebara S; Haddad F; Hayek G; Jabbour K
    J Cardiothorac Vasc Anesth; 2012 Jun; 26(3):387-90. PubMed ID: 22100211
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The value of pulse pressure and stroke volume variation as predictors of fluid responsiveness during open chest surgery.
    Wyffels PA; Sergeant P; Wouters PF
    Anaesthesia; 2010 Jul; 65(7):704-9. PubMed ID: 20477782
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Noninvasive pulse pressure variation and stroke volume variation to predict fluid responsiveness at multiple thresholds: a prospective observational study.
    Vos JJ; Poterman M; Salm PP; Van Amsterdam K; Struys MM; Scheeren TW; Kalmar AF
    Can J Anaesth; 2015 Nov; 62(11):1153-60. PubMed ID: 26335905
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of stroke volume variation with pulse pressure variation as a diagnostic indicator of fluid responsiveness in mechanically ventilated critically ill patients.
    Hong JQ; He HF; Chen ZY; Du ZS; Liu WF; Weng PQ; Huang HB
    Saudi Med J; 2014 Mar; 35(3):261-8. PubMed ID: 24623206
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Plethysmography variability index for prediction of fluid responsiveness during graded haemorrhage and transfusion in sevoflurane-anaesthetized mechanically ventilated dogs.
    Endo Y; Kawase K; Miyasho T; Sano T; Yamashita K; Muir WW
    Vet Anaesth Analg; 2017 Nov; 44(6):1303-1312. PubMed ID: 29113716
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Arm occlusion pressure is a useful predictor of an increase in cardiac output after fluid loading following cardiac surgery.
    Geerts BF; Maas J; de Wilde RB; Aarts LP; Jansen JR
    Eur J Anaesthesiol; 2011 Nov; 28(11):802-6. PubMed ID: 21799416
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Prediction of fluid responsiveness in acute respiratory distress syndrome patients ventilated with low tidal volume and high positive end-expiratory pressure.
    Huang CC; Fu JY; Hu HC; Kao KC; Chen NH; Hsieh MJ; Tsai YH
    Crit Care Med; 2008 Oct; 36(10):2810-6. PubMed ID: 18766099
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.