BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

185 related articles for article (PubMed ID: 22362192)

  • 1. Long-term results of a cardiovascular implantable electronic device wrapped with an expanded polytetrafluoroethylene sheet.
    Yashiro B; Shoda M; Tomizawa Y; Manaka T; Hagiwara N
    J Artif Organs; 2012 Sep; 15(3):244-9. PubMed ID: 22362192
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A method for successfully implanting an implantable cardioverter-defibrillator wrapped with an expanded polytetrafluoroethylene sheet in a patient with metal allergy.
    Morishita K; Ishihara A; Unno T; Murakami T; Okada K; Matsunaga H; Asada K; Omori Y; Kamoi Y; Tanaka T
    J Cardiol Cases; 2023 Jul; 28(1):40-43. PubMed ID: 37360834
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Low lateral thoracic site for cardiac implantable electronic device implantation: A viable alternative in patients with limited access options after infected device extraction.
    Liang JJ; Schaller RD; Modi DS; Enriquez A; Supple GE; Cooper JM
    Heart Rhythm; 2017 Oct; 14(10):1506-1514. PubMed ID: 28603001
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Cardiac implantable electronic device implantation and device-related infection.
    Modi V; Shah K; Ferraro B; Gasimli-Gamache L; Nanda S; Stevens S; Shirani J
    Europace; 2023 Aug; 25(9):. PubMed ID: 37572046
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Proposal for a Novel Score to Determine the Risk of Cardiac Implantable Electronic Device Infection.
    Calderón-Parra J; Sánchez-Chica E; Asensio-Vegas Á; Fernández-Lozano I; Toquero-Ramos J; Castro-Urda V; Royuela-Vicente A; Ramos-Martínez A
    Rev Esp Cardiol (Engl Ed); 2019 Oct; 72(10):806-812. PubMed ID: 30340923
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Management of Device Infections.
    Aljabri K; Garlitski A; Weinstock J; Madias C
    Card Electrophysiol Clin; 2018 Mar; 10(1):153-162. PubMed ID: 29428137
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Long-term outcomes following infection of cardiac implantable electronic devices: a prospective matched cohort study.
    Deharo JC; Quatre A; Mancini J; Khairy P; Le Dolley Y; Casalta JP; Peyrouse E; Prévôt S; Thuny F; Collart F; Raoult D; Habib G; Franceschi F
    Heart; 2012 May; 98(9):724-31. PubMed ID: 22523057
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cardiovascular Implantable Electronic Device Infections due to Propionibacterium Species.
    El Rafei A; Desimone DC; Sohail MR; Desimone CV; Steckelberg JM; Wilson WR; Baddour LM
    Pacing Clin Electrophysiol; 2016 Jun; 39(6):522-30. PubMed ID: 26970081
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Management of bacteremia in patients living with cardiovascular implantable electronic devices.
    DeSimone DC; Sohail MR
    Heart Rhythm; 2016 Nov; 13(11):2247-2252. PubMed ID: 27546815
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Cardiac implantable electronic devices in adults with tetralogy of Fallot.
    Egbe AC; Miranda WR; Madhavan M; Ammash NM; Missula VR; Al-Otaibi M; Fatola A; Kothapalli S; Connolly HM
    Heart; 2019 Apr; 105(7):538-544. PubMed ID: 30377259
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Predictors of Long-Term Infections After Cardiac Implantable Electronic Device Surgery - Utility of Novel PADIT and PACE DRAP Scores.
    Sławek-Szmyt S; Araszkiewicz A; Grygier M; Szmyt K; Chmielewska-Michalak L; Seniuk W; Waśniewski M; Smukowski T; Lesiak M; Mitkowski P
    Circ J; 2020 Sep; 84(10):1754-1763. PubMed ID: 32893235
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Clinical Characteristics and Outcome of Cardiovascular Implantable Electronic Device Infections in Turkey.
    Aydin M; Yildiz A; Kaya Z; Kaya Z; Basarir AO; Cakmak N; Donmez I; Morrad B; Avci A; Demir K; Cagliyan EC; Yuksel M; Elbey MA; Kayan F; Ozaydogdu N; Islamoglu Y; Cayli M; Alan S; Ulgen MS; Ozhan H
    Clin Appl Thromb Hemost; 2016 Jul; 22(5):459-64. PubMed ID: 25589093
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cardiovascular magnetic resonance imaging in patients with cardiac implantable electronic devices: best practice and real-world experience.
    Seewöster T; Löbe S; Hilbert S; Bollmann A; Sommer P; Lindemann F; Bacevičius J; Schöne K; Richter S; Döring M; Paetsch I; Hindricks G; Jahnke C
    Europace; 2019 Aug; 21(8):1220-1228. PubMed ID: 31131393
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Redo procedures and chronic renal dysfunction are associated with higher risk of cardiac electronic device infections.
    Morani G; Mugnai G; Bolzan B; Morosato M; Tomasi L; Ferrari S; Vassanelli C
    Minerva Cardioangiol; 2018 Jun; 66(3):225-232. PubMed ID: 29308851
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Preoperative skin antiseptics for prevention of cardiac implantable electronic device infections: a historical-controlled interventional trial comparing aqueous against alcoholic povidone-iodine solutions.
    Da Costa A; Tulane C; Dauphinot V; Terreaux J; Romeyer-Bouchard C; Gate-Martinet A; Levallois M; Isaaz K
    Europace; 2015 Jul; 17(7):1092-8. PubMed ID: 25917024
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Reimplantation and Repeat Infection After Cardiac-Implantable Electronic Device Infections: Experience From the MEDIC (Multicenter Electrophysiologic Device Infection Cohort) Database.
    Boyle TA; Uslan DZ; Prutkin JM; Greenspon AJ; Baddour LM; Danik SB; Tolosana JM; Le K; Miro JM; Peacock J; Sohail MR; Vikram HR; Carrillo RG
    Circ Arrhythm Electrophysiol; 2017 Mar; 10(3):. PubMed ID: 28292753
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Infections and associated costs following cardiovascular implantable electronic device implantations: a nationwide cohort study.
    Clémenty N; Carion PL; Léotoing L; Lamarsalle L; Wilquin-Bequet F; Brown B; Verhees KJP; Fernandes J; Deharo JC
    Europace; 2018 Dec; 20(12):1974-1980. PubMed ID: 29672690
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Transcutaneous lead implantation connected to an externalized pacemaker in patients with implantable cardiac defibrillator/pacemaker infection and pacemaker dependency.
    Pecha S; Aydin MA; Yildirim Y; Sill B; Reiter B; Wilke I; Reichenspurner H; Treede H
    Europace; 2013 Aug; 15(8):1205-9. PubMed ID: 23426553
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Increased long-term mortality in patients with cardiovascular implantable electronic device infections.
    Rizwan Sohail M; Henrikson CA; Jo Braid-Forbes M; Forbes KF; Lerner DJ
    Pacing Clin Electrophysiol; 2015 Feb; 38(2):231-9. PubMed ID: 25243484
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Approach to Diagnosis of Cardiovascular Implantable-Electronic-Device Infection.
    DeSimone DC; Sohail MR
    J Clin Microbiol; 2018 Jul; 56(7):. PubMed ID: 29695526
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.