These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
52 related articles for article (PubMed ID: 2236798)
1. [Sensing anomalies with the VVI pacemaker. Clinical study by Holter]. Beiras Torrado X; Crespo Carazo N; Amorín Ferreiro F; Molinero Somolinos F Rev Esp Cardiol; 1990; 43 Suppl 2():48-51. PubMed ID: 2236798 [TBL] [Abstract][Full Text] [Related]
2. Unipolar sensing in contemporary pacemakers: using myopotential testing to define optimal sensitivity settings. Exner DV; Rothschild JM; Heal S; Gillis AM J Interv Card Electrophysiol; 1998 Mar; 2(1):33-40. PubMed ID: 9869994 [TBL] [Abstract][Full Text] [Related]
3. [Transient pacemaker dysfunction and spontaneous arrhythmias in symptomatic and asymptomatic patients with ventricular demand pacemakers]. Brandes A; Bethge KP; Gonska BD; Diederich KW Z Kardiol; 1996 Apr; 85(4):237-47. PubMed ID: 8693766 [TBL] [Abstract][Full Text] [Related]
4. [Diagnosis of silent ischemia in patients with previous myocardial infarct, under 45 years of age]. Agoas R; Gomes V; Leiria G Rev Port Cardiol; 1990 Jun; 9(6):521-5. PubMed ID: 2248787 [TBL] [Abstract][Full Text] [Related]
5. [Arrhythmia in patients with a DDD bicameral pacemaker]. Occhetta E; Magnani A; Prando MD; Perucca A; Rossi L; Rognoni G; Rossi P G Ital Cardiol; 1986 Nov; 16(11):909-21. PubMed ID: 2435600 [TBL] [Abstract][Full Text] [Related]
6. Paradoxical atrial undersensing due to inappropriate atrial noise reversion of atrial fibrillation in dual-chamber pacemakers. Kolb C; Halbfass P; Zrenner B; Schmitt C J Cardiovasc Electrophysiol; 2005 Jul; 16(7):696-700. PubMed ID: 16050825 [TBL] [Abstract][Full Text] [Related]
7. Diaphragmatic myopotential oversensing in pacemaker-dependent patients with CRT-D devices. Santos KR; Adragão P; Cavaco D; Morgado FB; Candeias R; Lima S; Silva JA Europace; 2008 Dec; 10(12):1381-6. PubMed ID: 18757865 [TBL] [Abstract][Full Text] [Related]
8. The clinical incidence and significance of myopotential sensing with unipolar pacemakers. Fetter J; Bobeldyk GL; Engman FJ Pacing Clin Electrophysiol; 1984 Sep; 7(5):871-81. PubMed ID: 6207501 [TBL] [Abstract][Full Text] [Related]
9. Maintaining physiological pacing in AV block using a new generation single lead VDD pacemaker. Lau C; Nishimura SC; Harrison AW; Goldman BS Can J Cardiol; 1996 Jun; 12(6):579-83. PubMed ID: 8665420 [TBL] [Abstract][Full Text] [Related]
10. Evaluation of pacemaker telemetry as a diagnostic feature for detecting atrial tachyarrhythmias in patients with sick sinus syndrome. Kristensen L; Nielsen JC; Mortensen PT; Pedersen AK; Andersen HR Europace; 2004 Nov; 6(6):580-5. PubMed ID: 15519261 [TBL] [Abstract][Full Text] [Related]
12. Long-term comparison of unipolar and bipolar pacing and sensing, using a new multiprogrammable pacemaker system. Breivik K; Ohm OJ; Engedal H Pacing Clin Electrophysiol; 1983 May; 6(3 Pt 1):592-600. PubMed ID: 6191297 [TBL] [Abstract][Full Text] [Related]
13. Myopotential inhibition of unipolar QRS-inhibited (VVI) pacemakers, assessed by ambulatory Holter monitoring of the electrocardiogram. Breivik K; Ohm OJ Pacing Clin Electrophysiol; 1980 Jul; 3(4):470-8. PubMed ID: 6160541 [TBL] [Abstract][Full Text] [Related]
14. The use of permanent pacemakers in the detection of cardiac arrhythmias. Plummer CJ; Henderson S; Gardener L; McComb JM Europace; 2001 Jul; 3(3):229-32. PubMed ID: 11467465 [TBL] [Abstract][Full Text] [Related]
15. Atrial pacing and sensing characteristics in heart failure patients undergoing cardiac resynchronization therapy. Schuchert A; Aydin MA; Israel C; Gaby G; Paul V Europace; 2005 Mar; 7(2):165-9. PubMed ID: 15763532 [TBL] [Abstract][Full Text] [Related]
16. Atrial lead location at the Bachmann's bundle region results in a low incidence of far field R-wave sensing. Lewicka-Nowak E; Kutarski A; Dabrowska-Kugacka A; Rucinski P; Zagozdzon P; Raczak G Europace; 2008 Feb; 10(2):138-46. PubMed ID: 18192341 [TBL] [Abstract][Full Text] [Related]
17. Comparison of susceptibility of myopotential inhibition between AAI and VVI pacemakers. Ito H; Iesaka Y; Taniguchi K; Takeuchi J Jpn Heart J; 1987 Mar; 28(2):157-64. PubMed ID: 3599408 [TBL] [Abstract][Full Text] [Related]
18. [Incidence of atrial arrhythmia in patients with long term dual-chamber pacemakers. Contribution of the Holter function of pacemakers]. Garrigue S; Cazeau S; Ritter P; Lazarus A; Gras D; Mugica J Arch Mal Coeur Vaiss; 1996 Jul; 89(7):873-81. PubMed ID: 8869249 [TBL] [Abstract][Full Text] [Related]
19. [50 hz alternating current as a cause of inhibition of monopolar ventricular pacemakers]. Ruiz Granell R; Botella Solana S; García Civera R; Botella Marco JI; Morell Cabedo S; Sanjuán Máñez R; López Merino V Rev Esp Cardiol; 1990 Nov; 43(9):624-8. PubMed ID: 2099525 [TBL] [Abstract][Full Text] [Related]