These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

217 related articles for article (PubMed ID: 22371206)

  • 1. The accuracy of autotitrating CPAP-determined residual apnea-hypopnea index.
    Cilli A; Uzun R; Bilge U
    Sleep Breath; 2013 Mar; 17(1):189-93. PubMed ID: 22371206
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Accuracy of autotitrating CPAP to estimate the residual Apnea-Hypopnea Index in patients with obstructive sleep apnea on treatment with autotitrating CPAP.
    Desai H; Patel A; Patel P; Grant BJ; Mador MJ
    Sleep Breath; 2009 Nov; 13(4):383-90. PubMed ID: 19408029
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of the apnea-hypopnea index determined by the S8 auto-CPAP, a continuous positive airway pressure device, in patients with obstructive sleep apnea-hypopnea syndrome.
    Ueno K; Kasai T; Brewer G; Takaya H; Maeno K; Kasagi S; Kawana F; Ishiwata S; Narui K
    J Clin Sleep Med; 2010 Apr; 6(2):146-51. PubMed ID: 20411691
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Accuracy of a novel auto-CPAP device to evaluate the residual apnea-hypopnea index in patients with obstructive sleep apnea.
    Nigro CA; González S; Arce A; Aragone MR; Nigro L
    Sleep Breath; 2015 May; 19(2):569-78. PubMed ID: 25115886
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Polysomnography in patients with obstructive sleep apnea: an evidence-based analysis.
    Medical Advisory Secretariat
    Ont Health Technol Assess Ser; 2006; 6(13):1-38. PubMed ID: 23074483
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Continuous positive airway pressure device-based automated detection of obstructive sleep apnea compared to standard laboratory polysomnography.
    Prasad B; Carley DW; Herdegen JJ
    Sleep Breath; 2010 Jun; 14(2):101-7. PubMed ID: 19826848
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison between the apnea-hypopnea indices determined by the REMstar Auto M series and those determined by standard in-laboratory polysomnography in patients with obstructive sleep apnea.
    Ikeda Y; Kasai T; Kawana F; Kasagi S; Takaya H; Ishiwata S; Narui K
    Intern Med; 2012; 51(20):2877-85. PubMed ID: 23064561
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Accuracy of residual apnea-hypopnea index obtained using the continuous positive airway pressure device: application of new version 2.0 scoring rules for respiratory events during sleep.
    Kim DE; Hwangbo Y; Bae JH; Yang KI
    Sleep Breath; 2015 Dec; 19(4):1335-41. PubMed ID: 26407962
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Validation of the System One RemStar Auto A-Flex for Obstructive Sleep Apnea Treatment and Detection of Residual Apnea-Hypopnea Index: A European Randomized Trial.
    Gagnadoux F; Pevernagie D; Jennum P; Lon N; Loiodice C; Tamisier R; van Mierlo P; Trzepizur W; Neddermann M; Machleit A; Jasko J; Pépin JL
    J Clin Sleep Med; 2017 Feb; 13(2):283-290. PubMed ID: 27784415
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Follow-up assessment of CPAP efficacy in patients with obstructive sleep apnea using an ambulatory device based on peripheral arterial tonometry.
    Pittman SD; Pillar G; Berry RB; Malhotra A; MacDonald MM; White DP
    Sleep Breath; 2006 Sep; 10(3):123-31. PubMed ID: 16586136
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Diagnosis and initial management of obstructive sleep apnea without polysomnography: a randomized validation study.
    Mulgrew AT; Fox N; Ayas NT; Ryan CF
    Ann Intern Med; 2007 Feb; 146(3):157-66. PubMed ID: 17283346
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Performance of a commercial smart watch compared to polysomnography reference for overnight continuous oximetry measurement and sleep apnea evaluation.
    Browne SH; Vaida F; Umlauf A; Kim J; DeYoung P; Owens RL
    J Clin Sleep Med; 2024 Sep; 20(9):1479-1488. PubMed ID: 38652502
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Residual sleep apnea on polysomnography after 3 months of CPAP therapy: clinical implications, predictors and patterns.
    Mulgrew AT; Lawati NA; Ayas NT; Fox N; Hamilton P; Cortes L; Ryan CF
    Sleep Med; 2010 Feb; 11(2):119-25. PubMed ID: 20083429
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Is the CPAP estimate of the apnea-hypopnea index on therapy clinically useful?
    Mador MJ
    Sleep Breath; 2013 Mar; 17(1):15-6. PubMed ID: 22392652
    [No Abstract]   [Full Text] [Related]  

  • 15. Continuous positive airway pressure usage in hospitalized patients with known obstructive sleep apnea: discrepancy between admission pressure settings and laboratory-determined settings.
    Saini P; Klada E; Patel V; Zaw M; Dubrovsky B; George L; Bachman EM; Weingarten JA
    Sleep Breath; 2017 May; 21(2):347-353. PubMed ID: 27796718
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Reliability of respiratory event detection with continuous positive airway pressure in moderate to severe obstructive sleep apnea - comparison of polysomnography with a device-based analysis.
    Richter M; Schroeder M; Domanski U; Schwaibold M; Nilius G
    Sleep Breath; 2023 Aug; 27(4):1639-1650. PubMed ID: 36394692
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Analysis of mandibular jaw movements to assess ventilatory support management of children with obstructive sleep apnea syndrome treated with positive airway pressure therapies.
    Cassibba J; Aubertin G; Martinot JB; Le Dong N; Hullo E; Beydon N; Dupont-Athénor A; Mortamet G; Pépin JL
    Pediatr Pulmonol; 2024 Jul; 59(7):1905-1911. PubMed ID: 38593278
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Central sleep apnea on commencement of continuous positive airway pressure in patients with a primary diagnosis of obstructive sleep apnea-hypopnea.
    Lehman S; Antic NA; Thompson C; Catcheside PG; Mercer J; McEvoy RD
    J Clin Sleep Med; 2007 Aug; 3(5):462-6. PubMed ID: 17803008
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Clinical predictors of effective continuous positive airway pressure in patients with obstructive sleep apnea/hypopnea syndrome.
    Lai CC; Friedman M; Lin HC; Wang PC; Hwang MS; Hsu CM; Lin MC; Chin CH
    Laryngoscope; 2015 Aug; 125(8):1983-7. PubMed ID: 25582398
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pressure-Relief Features of Fixed and Autotitrating Continuous Positive Airway Pressure May Impair Their Efficacy: Evaluation with a Respiratory Bench Model.
    Zhu K; Aouf S; Roisman G; Escourrou P
    J Clin Sleep Med; 2016 Mar; 12(3):385-92. PubMed ID: 26564383
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.