These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

93 related articles for article (PubMed ID: 2237265)

  • 1. Accuracy of pulse oximetry during moderate exercise: a comparative study.
    Barthélémy JC; Geyssant A; Riffat J; Antoniadis A; Berruyer J; Lacour JR
    Scand J Clin Lab Invest; 1990 Sep; 50(5):533-9. PubMed ID: 2237265
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Accuracy and precision of fourteen pulse oximeters.
    Hannhart B; Haberer JP; Saunier C; Laxenaire MC
    Eur Respir J; 1991 Jan; 4(1):115-9. PubMed ID: 2026231
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Accuracy of pulse oximetry during intense exercise under severe hypoxic conditions.
    Benoit H; Costes F; Feasson L; Lacour JR; Roche F; Denis C; Geyssant A; Barthélémy JC
    Eur J Appl Physiol Occup Physiol; 1997; 76(3):260-3. PubMed ID: 9286606
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of oxygen saturation by pulse oximetry and co-oximetry during exercise testing in patients with COPD.
    McGovern JP; Sasse SA; Stansbury DW; Causing LA; Light RW
    Chest; 1996 May; 109(5):1151-5. PubMed ID: 8625659
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The effects of motion artifact and low perfusion on the performance of a new generation of pulse oximeters in volunteers undergoing hypoxemia.
    Gehring H; Hornberger C; Matz H; Konecny E; Schmucker P
    Respir Care; 2002 Jan; 47(1):48-60. PubMed ID: 11749687
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of methemoglobin detection by pulse CO-oximetry during hypoxia.
    Feiner JR; Bickler PE; Mannheimer PD
    Anesth Analg; 2010 Jul; 111(1):143-8. PubMed ID: 20007731
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Testing and comparison of the accuracy and precision of 5 pulse oximeters].
    Nørreslet J; Ahlburg P; Knage K; Rasmussen JB
    Ugeskr Laeger; 1990 Jun; 152(26):1906-9. PubMed ID: 2363229
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Saturation by pulse oximetry: comparison of the results obtained by instruments of different brands.
    Thilo EH; Andersen D; Wasserstein ML; Schmidt J; Luckey D
    J Pediatr; 1993 Apr; 122(4):620-6. PubMed ID: 7681875
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Errors in 14 pulse oximeters during profound hypoxia.
    Severinghaus JW; Naifeh KH; Koh SO
    J Clin Monit; 1989 Apr; 5(2):72-81. PubMed ID: 2723709
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reliability of six pulse oximeters in chronic obstructive pulmonary disease.
    Hannhart B; Michalski H; Delorme N; Chapparo G; Polu JM
    Chest; 1991 Apr; 99(4):842-6. PubMed ID: 2009785
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Accuracy of three pulse oximeters during exercise and hypoxemia in patients with cystic fibrosis.
    Orenstein DM; Curtis SE; Nixon PA; Hartigan ER
    Chest; 1993 Oct; 104(4):1187-90. PubMed ID: 8404189
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Validity of pulse oximetry during exercise in elite endurance athletes.
    Martin D; Powers S; Cicale M; Collop N; Huang D; Criswell D
    J Appl Physiol (1985); 1992 Feb; 72(2):455-8. PubMed ID: 1559919
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparative accuracy of pulse oximetry and transcutaneous oxygen in assessing arterial saturation in pediatric intensive care.
    Ross Russell RI; Helms PJ
    Crit Care Med; 1990 Jul; 18(7):725-7. PubMed ID: 2364712
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy of pulse oximeters in estimating heart rate at rest and during exercise.
    Iyriboz Y; Powers S; Morrow J; Ayers D; Landry G
    Br J Sports Med; 1991 Sep; 25(3):162-4. PubMed ID: 1777787
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Accuracy of pulse oximetry to estimate HbO2 fraction of total Hb during exercise.
    Powers SK; Dodd S; Freeman J; Ayers GD; Samson H; McKnight T
    J Appl Physiol (1985); 1989 Jul; 67(1):300-4. PubMed ID: 2759956
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accuracy of two pulse oximeters at low arterial hemoglobin-oxygen saturation.
    Carter BG; Carlin JB; Tibballs J; Mead H; Hochmann M; Osborne A
    Crit Care Med; 1998 Jun; 26(6):1128-33. PubMed ID: 9635666
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [A comparative study of five pulse oximeters].
    Shitikov II; Flerov EV; Arsen'ev SB
    Med Tekh; 1993; (1):21-4. PubMed ID: 8502136
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Performance of three new-generation pulse oximeters during motion and low perfusion in volunteers.
    Shah N; Ragaswamy HB; Govindugari K; Estanol L
    J Clin Anesth; 2012 Aug; 24(5):385-91. PubMed ID: 22626683
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Accuracy of measurements of Kontrol 7840, Nellcor N200 and Radiometer OX13 pulse oximeters in infants and young children].
    Poets CF; Seidenberg J; Wilken M; von der Hardt H
    Klin Padiatr; 1993; 205(2):107-10. PubMed ID: 8487476
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Accuracy of response of six pulse oximeters to profound hypoxia.
    Severinghaus JW; Naifeh KH
    Anesthesiology; 1987 Oct; 67(4):551-8. PubMed ID: 3662082
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.