These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

82 related articles for article (PubMed ID: 22374034)

  • 1. Blood glucose measurement in flap monitoring for salvage of flaps from venous thrombosis.
    Hara H; Mihara M; Iida T; Narushima M; Koshima I
    Plast Reconstr Surg; 2012 Mar; 129(3):587e-589e. PubMed ID: 22374034
    [No Abstract]   [Full Text] [Related]  

  • 2. Blood glucose measurement for flap monitoring to salvage flaps from venous thrombosis.
    Hara H; Mihara M; Iida T; Narushima M; Todokoro T; Yamamoto T; Koshima I
    J Plast Reconstr Aesthet Surg; 2012 May; 65(5):616-9. PubMed ID: 22153849
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Diagnostic Accuracy of Blood Glucose Measurements in Detecting Venous Compromise in Flaps.
    Bashir MM; Tayyab Z; Afzal S; Khan FA
    J Craniofac Surg; 2015 Jul; 26(5):1492-4. PubMed ID: 26114526
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Flap blood glucose measurement for flap monitoring and early detection of circulatory problems.
    Anwar MH; Dwivedi R; Singh B; Agarwal V; Agarwal P; Sharma D
    Trop Doct; 2024 Jul; 54(3):248-250. PubMed ID: 38497138
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Flap Blood Glucose as a Sensitive and Specific Indicator for Flap Venous Congestion: A Rodent Model Study.
    Mochizuki K; Mochizuki M; Gonda K
    Plast Reconstr Surg; 2019 Sep; 144(3):409e-418e. PubMed ID: 31461018
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Continuous postoperative monitoring of cutaneous free flaps using near infrared spectroscopy.
    Repez A; Oroszy D; Arnez ZM
    J Plast Reconstr Aesthet Surg; 2008; 61(1):71-7. PubMed ID: 17532278
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A simplest method of flap monitoring.
    Sakakibara S; Hashikawa K; Omori M; Terashi H; Tahara S
    J Reconstr Microsurg; 2010 Sep; 26(7):433-4. PubMed ID: 20336602
    [No Abstract]   [Full Text] [Related]  

  • 8. Analysis of 59 cases with free flap thrombosis after reconstructive surgery for head and neck cancer.
    Yoshimoto S; Kawabata K; Mitani H
    Auris Nasus Larynx; 2010 Apr; 37(2):205-11. PubMed ID: 19700252
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Capillary measurement of lactate and glucose for free flap monitoring.
    Henault B; Pluvy I; Pauchot J; Sinna R; Labruère-Chazal C; Zwetyenga N
    Ann Chir Plast Esthet; 2014 Feb; 59(1):15-21. PubMed ID: 24074909
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Trials and tribulations with the inferior gluteal artery perforator flap in autologous breast reconstruction.
    Mirzabeigi MN; Au A; Jandali S; Natoli N; Sbitany H; Serletti JM
    Plast Reconstr Surg; 2011 Dec; 128(6):614e-624e. PubMed ID: 22094760
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Thrombolytic therapy: what is its role in free flap salvage?
    Yii NW; Evans GR; Miller MJ; Reece GP; Langstein H; Chang D; Kroll SS; Wang B; Robb GL
    Ann Plast Surg; 2001 Jun; 46(6):601-4. PubMed ID: 11405358
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Venous thrombosis after microvascular free-tissue transfer in head and neck cancer reconstruction.
    Fukuiwa T; Nishimoto K; Hayashi T; Kurono Y
    Auris Nasus Larynx; 2008 Sep; 35(3):390-6. PubMed ID: 18242027
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Postoperative blood flow monitoring after free-tissue transfer by means of the hydrogen clearance technique.
    Machens HG; Mailaender P; Reimer R; Pallua N; Lei Y; Berger A
    Plast Reconstr Surg; 1997 Feb; 99(2):493-505. PubMed ID: 9030160
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Distinguishing laser Doppler flowmetric responses between arterial and venous obstructions in flaps.
    Yuen JC; Feng Z
    J Reconstr Microsurg; 2000 Nov; 16(8):629-35. PubMed ID: 11127286
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Free flap microcirculatory monitoring correlates to free flap temperature assessment.
    Kraemer R; Lorenzen J; Knobloch K; Papst S; Kabbani M; Koennecker S; Vogt PM
    J Plast Reconstr Aesthet Surg; 2011 Oct; 64(10):1353-8. PubMed ID: 21664205
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Elevated coagulation factor VIII, postoperative thrombosis and flap failure in late breast reconstruction with a free TRAM flap: a case report.
    Höijer P; Olsson E
    J Plast Reconstr Aesthet Surg; 2006; 59(1):102-4. PubMed ID: 16482798
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Salvage of a free flap after late total thrombosis of the flap and revascularisation.
    Ribuffo D; Chiummariello S; Cigna E; Scuderi N
    Scand J Plast Reconstr Surg Hand Surg; 2004; 38(1):50-2. PubMed ID: 15074725
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Noninvasive microcirculatory flap monitoring or implantable doppler probes: only an adjunct to clinical assessment for reconstructive microsurgery?
    Knobloch K
    J Reconstr Microsurg; 2009 May; 25(4):271-2. PubMed ID: 18825614
    [No Abstract]   [Full Text] [Related]  

  • 19. Salvage of free flaps after venous thrombosis: case report.
    Bonde CT; Heslet L; Jansen E; Elberg JJ
    Microsurgery; 2004; 24(4):298-301. PubMed ID: 15274187
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Continuous free-flap monitoring with tissue-oxygen measurements: experiences of the last years].
    Kamolz LP; Schrögendorfer KF; Giovanoli P; Koller R; Frey M
    Handchir Mikrochir Plast Chir; 2002 May; 34(3):195-200. PubMed ID: 12203156
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.