These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

76 related articles for article (PubMed ID: 22378541)

  • 1. Small-caliber vascular prosthesis prototype based on controlled release of heparin from mesochannels and its enhanced biocompatibility.
    Zhou Y; Li K; Yang JY; Guan CX; Wang Y; Liu CJ; Zhu JH
    Small; 2012 May; 8(9):1373-83. PubMed ID: 22378541
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A novel bioengineered small-caliber vascular graft incorporating heparin and sirolimus: excellent 6-month patency.
    Ishii Y; Sakamoto S; Kronengold RT; Virmani R; Rivera EA; Goldman SM; Prechtel EJ; Hill JG; Damiano RJ
    J Thorac Cardiovasc Surg; 2008 Jun; 135(6):1237-45; discussion 1245-6. PubMed ID: 18544361
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Rapamycin-coated expanded polytetrafluoroethylene bypass grafts exhibit decreased anastomotic neointimal hyperplasia in a porcine model.
    Cagiannos C; Abul-Khoudoud OR; DeRijk W; Shell DH; Jennings LK; Tolley EA; Handorf CR; Fabian TC
    J Vasc Surg; 2005 Nov; 42(5):980-8. PubMed ID: 16275457
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Gelatin/heparin coated bio-inspired polyurethane composite fibers to construct small-caliber artificial blood vessel grafts.
    Xiang Z; Chen H; Xu B; Wang H; Zhang T; Guan X; Ma Z; Liang K; Shi Q
    Int J Biol Macromol; 2024 Jun; 269(Pt 1):131849. PubMed ID: 38670202
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Hemocompatibility evaluation in vitro of small-caliber expanded polytetrafluoroethylene vessel with silk fibroin coating sulfonated by low temperature plasma].
    Li SB; Yan YS; Li H; Chen KT; Tong J; Chen QQ; Zhang FW; Xiao F
    Nan Fang Yi Ke Da Xue Xue Bao; 2010 Sep; 30(9):2100-3. PubMed ID: 20855261
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of platelet deposition and neointimal hyperplasia of heparin-coated small-caliber ePTFE grafts in a canine femoral artery bypass model.
    Lin PH; Bush RL; Yao Q; Lumsden AB; Chen C
    J Surg Res; 2004 May; 118(1):45-52. PubMed ID: 15093716
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Silyl-heparin bonding improves the patency and in vivo thromboresistance of carbon-coated polytetrafluoroethylene vascular grafts.
    Laredo J; Xue L; Husak VA; Ellinger J; Singh G; Zamora PO; Greisler HP
    J Vasc Surg; 2004 May; 39(5):1059-65. PubMed ID: 15111862
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Heparin-induced thrombocytopenia after implantation of a heparin-bonded polytetrafluoroethylene lower extremity bypass graft: A case report and plan for management.
    Thakur S; Pigott JP; Comerota AJ
    J Vasc Surg; 2009 Apr; 49(4):1037-40. PubMed ID: 19341891
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Development and validation of small-diameter vascular tissue from a decellularized scaffold coated with heparin and vascular endothelial growth factor.
    Zhou M; Liu Z; Wei Z; Liu C; Qiao T; Ran F; Bai Y; Jiang X; Ding Y
    Artif Organs; 2009 Mar; 33(3):230-9. PubMed ID: 19245522
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Improved healing of small-caliber, long-fibril expanded polytetrafluoroethylene vascular grafts by covalent bonding of fibronectin.
    Shimada T; Nishibe T; Miura H; Hazama K; Kato H; Kudo F; Murashita T; Okuda Y
    Surg Today; 2004; 34(12):1025-30. PubMed ID: 15580386
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Enhanced intimal thickening of expanded polytetrafluoroethylene grafts coated with fibrin or fibrin-releasing vascular endothelial growth factor in the pig carotid artery interposition model.
    Walpoth BH; Zammaretti P; Cikirikcioglu M; Khabiri E; Djebaili MK; Pache JC; Tille JC; Aggoun Y; Morel D; Kalangos A; Hubbell JA; Zisch AH
    J Thorac Cardiovasc Surg; 2007 May; 133(5):1163-70. PubMed ID: 17467424
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Short-term patency of 1 mm diameter PTFE prosthesis: an angiographic, Doppler-flowmetric and morphological experimental study.
    Durante CM; Camboni A; Bianchi S; Macchiarelli G
    Ital J Anat Embryol; 2005; 110(2 Suppl 1):117-25. PubMed ID: 16101029
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Coils and tubes releasing heparin. Studies on a new vascular graft prototype.
    Aldenhoff YB; Knetsch ML; Hanssen JH; Lindhout T; Wielders SJ; Koole LH
    Biomaterials; 2004 Jul; 25(16):3125-33. PubMed ID: 14980407
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Linker-free covalent immobilization of heparin, SDF-1α, and CD47 on PTFE surface for antithrombogenicity, endothelialization and anti-inflammation.
    Gao A; Hang R; Li W; Zhang W; Li P; Wang G; Bai L; Yu XF; Wang H; Tong L; Chu PK
    Biomaterials; 2017 Sep; 140():201-211. PubMed ID: 28662400
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Blood compatibility of human amniotic membrane compared with heparin-coated ePTFE for vascular tissue engineering.
    Kakavand M; Yazdanpanah G; Ahmadiani A; Niknejad H
    J Tissue Eng Regen Med; 2017 Jun; 11(6):1701-1709. PubMed ID: 26190586
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The modulation of platelet and endothelial cell adhesion to vascular graft materials by perlecan.
    Lord MS; Yu W; Cheng B; Simmons A; Poole-Warren L; Whitelock JM
    Biomaterials; 2009 Oct; 30(28):4898-906. PubMed ID: 19540587
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Programmed Release of Multimodal, Cross-Linked Vascular Endothelial Growth Factor and Heparin Layers on Electrospun Polycaprolactone Vascular Grafts.
    Wang D; Wang X; Zhang Z; Wang L; Li X; Xu Y; Ren C; Li Q; Turng LS
    ACS Appl Mater Interfaces; 2019 Sep; 11(35):32533-32542. PubMed ID: 31393107
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Vascular endothelial growth factor enhances vascularization in microporous small caliber polyurethane grafts.
    Masuda S; Doi K; Satoh S; Oka T; Matsuda T
    ASAIO J; 1997; 43(5):M530-4. PubMed ID: 9360099
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Improvement of patency rate in heparin-coated small synthetic vascular grafts.
    Walpoth BH; Rogulenko R; Tikhvinskaia E; Gogolewski S; Schaffner T; Hess OM; Althaus U
    Circulation; 1998 Nov; 98(19 Suppl):II319-23; discussion II324. PubMed ID: 9852921
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Heparin immobilization reduces thrombogenicity of small-caliber expanded polytetrafluoroethylene grafts.
    Heyligers JM; Verhagen HJ; Rotmans JI; Weeterings C; de Groot PG; Moll FL; Lisman T
    J Vasc Surg; 2006 Mar; 43(3):587-91. PubMed ID: 16520178
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.