These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
162 related articles for article (PubMed ID: 22380355)
1. Verification of proton range, position, and intensity in IMPT with a 3D liquid scintillator detector system. Archambault L; Poenisch F; Sahoo N; Robertson D; Lee A; Gillin MT; Mohan R; Beddar S Med Phys; 2012 Mar; 39(3):1239-46. PubMed ID: 22380355 [TBL] [Abstract][Full Text] [Related]
2. Exploration of the potential of liquid scintillators for real-time 3D dosimetry of intensity modulated proton beams. Beddar S; Archambault L; Sahoo N; Poenisch F; Chen GT; Gillin MT; Mohan R Med Phys; 2009 May; 36(5):1736-43. PubMed ID: 19544791 [TBL] [Abstract][Full Text] [Related]
4. High spatiotemporal resolution scintillation imaging of pulsed pencil beam scanning proton beams produced by a gantry-mounted synchrocyclotron. Goddu SM; Hao Y; Ji Z; Setianegara J; Liu F; Green W; Sobotka LG; Zhao T; Perkins S; Darafsheh A Med Phys; 2024 Jul; 51(7):4996-5006. PubMed ID: 38748998 [TBL] [Abstract][Full Text] [Related]
5. Time structure of pencil beam scanning proton FLASH beams measured with scintillator detectors and compared with log files. Kanouta E; Johansen JG; Kertzscher G; Sitarz MK; Sørensen BS; Poulsen PR Med Phys; 2022 Mar; 49(3):1932-1943. PubMed ID: 35076947 [TBL] [Abstract][Full Text] [Related]
6. 3D reconstruction of scintillation light emission from proton pencil beams using limited viewing angles-a simulation study. Hui C; Robertson D; Beddar S Phys Med Biol; 2014 Aug; 59(16):4477-92. PubMed ID: 25054735 [TBL] [Abstract][Full Text] [Related]
7. Fast range measurement of spot scanning proton beams using a volumetric liquid scintillator detector. Hui C; Robertson D; Alsanea F; Beddar S Biomed Phys Eng Express; 2015 Aug; 1(2):. PubMed ID: 27274863 [TBL] [Abstract][Full Text] [Related]
8. Development of a three-dimensional scintillation detector for pencil beam verification in proton therapy patient-specific quality assurance. Frelin AM; Daviau G; Bui MHH; Fontbonne C; Fontbonne JM; Lebhertz D; Mainguy E; Moignier C; Thariat J; Vela A Med Phys; 2024 Dec; 51(12):9318-9329. PubMed ID: 39255360 [TBL] [Abstract][Full Text] [Related]
9. Integrated beam orientation and scanning-spot optimization in intensity-modulated proton therapy for brain and unilateral head and neck tumors. Gu W; O'Connor D; Nguyen D; Yu VY; Ruan D; Dong L; Sheng K Med Phys; 2018 Apr; 45(4):1338-1350. PubMed ID: 29394454 [TBL] [Abstract][Full Text] [Related]
11. Performance characterization of a 3D liquid scintillation detector for discrete spot scanning proton beam systems. Darne CD; Alsanea F; Robertson DG; Sahoo N; Beddar S Phys Med Biol; 2017 Jun; 62(14):5652-5667. PubMed ID: 28593931 [TBL] [Abstract][Full Text] [Related]
12. Quantitative, real-time scintillation imaging for experimental comparison of different dose and dose rate estimations in UHDR proton pencil beams. Clark M; Harms J; Vasyltsiv R; Sloop A; Kozelka J; Simon B; Zhang R; Gladstone D; Bruza P Med Phys; 2024 Sep; 51(9):6402-6411. PubMed ID: 38860497 [TBL] [Abstract][Full Text] [Related]
13. Comparison between the lateral penumbra of a collimated double-scattered beam and uncollimated scanning beam in proton radiotherapy. Safai S; Bortfeld T; Engelsman M Phys Med Biol; 2008 Mar; 53(6):1729-50. PubMed ID: 18367800 [TBL] [Abstract][Full Text] [Related]
14. Implication of spot position error on plan quality and patient safety in pencil-beam-scanning proton therapy. Yu J; Beltran CJ; Herman MG Med Phys; 2014 Aug; 41(8):081706. PubMed ID: 25086516 [TBL] [Abstract][Full Text] [Related]
17. Ionization quenching correction for a 3D scintillator detector exposed to scanning proton beams. Alsanea F; Darne C; Robertson D; Beddar S Phys Med Biol; 2020 Apr; 65(7):075005. PubMed ID: 32079001 [TBL] [Abstract][Full Text] [Related]
18. Determination of the Range and Spread-Out Bragg Peak Width of Proton Beams Using a Large-Volume Liquid Scintillator. Henry T; Robertson D; Therriault-Proulx F; Beddar S Int J Part Ther; 2017; 4(1):1-6. PubMed ID: 31773000 [TBL] [Abstract][Full Text] [Related]
19. Factors influencing the performance of patient specific quality assurance for pencil beam scanning IMPT fields. Trnková P; Bolsi A; Albertini F; Weber DC; Lomax AJ Med Phys; 2016 Nov; 43(11):5998. PubMed ID: 27806620 [TBL] [Abstract][Full Text] [Related]
20. The M. D. Anderson proton therapy system. Smith A; Gillin M; Bues M; Zhu XR; Suzuki K; Mohan R; Woo S; Lee A; Komaki R; Cox J; Hiramoto K; Akiyama H; Ishida T; Sasaki T; Matsuda K Med Phys; 2009 Sep; 36(9):4068-83. PubMed ID: 19810479 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]