BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

292 related articles for article (PubMed ID: 22383673)

  • 1. Rationale of dead space measurement by volumetric capnography.
    Tusman G; Sipmann FS; Bohm SH
    Anesth Analg; 2012 Apr; 114(4):866-74. PubMed ID: 22383673
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Corrections of Enghoff's dead space formula for shunt effects still overestimate Bohr's dead space.
    Suarez-Sipmann F; Santos A; Böhm SH; Borges JB; Hedenstierna G; Tusman G
    Respir Physiol Neurobiol; 2013 Oct; 189(1):99-105. PubMed ID: 23827851
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Validation of Bohr dead space measured by volumetric capnography.
    Tusman G; Sipmann FS; Borges JB; Hedenstierna G; Bohm SH
    Intensive Care Med; 2011 May; 37(5):870-4. PubMed ID: 21359609
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Volumetric capnography in the mechanically ventilated patient.
    Blanch L; Romero PV; Lucangelo U
    Minerva Anestesiol; 2006 Jun; 72(6):577-85. PubMed ID: 16682932
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Time and volume dependence of dead space in healthy and surfactant-depleted rat lungs during spontaneous breathing and mechanical ventilation.
    Dassow C; Schwenninger D; Runck H; Guttmann J
    J Appl Physiol (1985); 2013 Nov; 115(9):1268-74. PubMed ID: 23950167
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Assessment of Bohr and Enghoff Dead Space Equations in Mechanically Ventilated Children.
    Bourgoin P; Baudin F; Brossier D; Emeriaud G; Wysocki M; Jouvet P
    Respir Care; 2017 Apr; 62(4):468-474. PubMed ID: 28223465
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Volumetric capnography: the time has come.
    Suarez-Sipmann F; Bohm SH; Tusman G
    Curr Opin Crit Care; 2014 Jun; 20(3):333-9. PubMed ID: 24785676
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of three tidal volumes (10, 12 and 15 mL kg
    Bumbacher S; Schramel JP; Mosing M
    Vet Anaesth Analg; 2017 Jul; 44(4):775-784. PubMed ID: 28807576
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Assessment of dead-space ventilation in patients with acute respiratory distress syndrome: a prospective observational study.
    Doorduin J; Nollet JL; Vugts MP; Roesthuis LH; Akankan F; van der Hoeven JG; van Hees HW; Heunks LM
    Crit Care; 2016 May; 20(1):121. PubMed ID: 27145818
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Volume Capnography in the Intensive Care Unit: Physiological Principles, Measurements, and Calculations.
    Kreit JW
    Ann Am Thorac Soc; 2019 Mar; 16(3):291-300. PubMed ID: 30657700
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Calculation of physiologic dead space: comparison of ventilator volumetric capnography to measurements by metabolic analyzer and volumetric CO2 monitor.
    Siobal MS; Ong H; Valdes J; Tang J
    Respir Care; 2013 Jul; 58(7):1143-51. PubMed ID: 23232740
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Predicting dead space ventilation in critically ill patients using clinically available data.
    Frankenfield DC; Alam S; Bekteshi E; Vender RL
    Crit Care Med; 2010 Jan; 38(1):288-91. PubMed ID: 19789453
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Noninvasive measurement of mean alveolar carbon dioxide tension and Bohr's dead space during tidal breathing.
    Koulouris NG; Latsi P; Dimitroulis J; Jordanoglou B; Gaga M; Jordanoglou J
    Eur Respir J; 2001 Jun; 17(6):1167-74. PubMed ID: 11491160
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Monitoring Dead Space in Mechanically Ventilated Children: Volumetric Capnography Versus Time-Based Capnography.
    Bhalla AK; Rubin S; Newth CJ; Ross P; Morzov R; Soto-Campos G; Khemani R
    Respir Care; 2015 Nov; 60(11):1548-55. PubMed ID: 26199451
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Capnogram slope and ventilation dead space parameters: comparison of mainstream and sidestream techniques.
    Balogh AL; Petak F; Fodor GH; Tolnai J; Csorba Z; Babik B
    Br J Anaesth; 2016 Jul; 117(1):109-17. PubMed ID: 27317710
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accuracy of physiologic dead space measurements in patients with acute respiratory distress syndrome using volumetric capnography: comparison with the metabolic monitor method.
    Kallet RH; Daniel BM; Garcia O; Matthay MA
    Respir Care; 2005 Apr; 50(4):462-7. PubMed ID: 15807908
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Physiologic Factors Influencing the Arterial-To-End-Tidal CO
    Mosing M; Böhm SH; Rasis A; Hoosgood G; Auer U; Tusman G; Bettschart-Wolfensberger R; Schramel JP
    Front Vet Sci; 2018; 5():58. PubMed ID: 29644221
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Volumetric capnography as a screening test for pulmonary embolism in the emergency department.
    Verschuren F; Liistro G; Coffeng R; Thys F; Roeseler J; Zech F; Reynaert M
    Chest; 2004 Mar; 125(3):841-50. PubMed ID: 15006940
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The effects of passive humidifier dead space on respiratory variables in paralyzed and spontaneously breathing patients.
    Campbell RS; Davis K; Johannigman JA; Branson RD
    Respir Care; 2000 Mar; 45(3):306-12. PubMed ID: 10771799
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Clinical use of volumetric capnography in mechanically ventilated patients.
    Kremeier P; Böhm SH; Tusman G
    J Clin Monit Comput; 2020 Feb; 34(1):7-16. PubMed ID: 31152285
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.