BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

197 related articles for article (PubMed ID: 22392259)

  • 1. Modified tension band for displaced type 2 lateral end clavicle fractures.
    Rijal L; Sagar G; Joshi A; Joshi KN
    Int Orthop; 2012 Jul; 36(7):1417-22. PubMed ID: 22392259
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Tension band suturing for the treatment of displaced type 2 lateral end clavicle fractures.
    Badhe SP; Lawrence TM; Clark DI
    Arch Orthop Trauma Surg; 2007 Jan; 127(1):25-8. PubMed ID: 16865401
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Modified tension band fixation and coracoclavicular stabilisation for unstable distal clavicle fracture.
    Choi S; Kim SR; Kang H; Kim D; Park YG
    Injury; 2015 Feb; 46(2):259-64. PubMed ID: 25458056
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Patella fracture fixation with suture and wire: you reap what you sew.
    Egol K; Howard D; Monroy A; Crespo A; Tejwani N; Davidovitch R
    Iowa Orthop J; 2014; 34():63-7. PubMed ID: 25328461
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparing hook plates and Kirschner tension band wiring for unstable lateral clavicle fractures.
    Wu K; Chang CH; Yang RS
    Orthopedics; 2011 Nov; 34(11):e718-23. PubMed ID: 22049952
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Treatment of unstable distal clavicle fractures using two suture anchors and suture tension bands.
    Shin SJ; Roh KJ; Kim JO; Sohn HS
    Injury; 2009 Dec; 40(12):1308-12. PubMed ID: 19524227
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Minimally invasive plate osteosynthesis (MIPO) in AO/OTA type B displaced clavicle fractures.
    Kundangar RS; Mohanty SP; Bhat NS
    Musculoskelet Surg; 2019 Aug; 103(2):191-197. PubMed ID: 30519988
    [TBL] [Abstract][Full Text] [Related]  

  • 8. All arthroscopic coracoclavicular button fixation is efficient for Neer type II distal clavicle fractures.
    Kapicioglu M; Erden T; Bilgin E; Bilsel K
    Knee Surg Sports Traumatol Arthrosc; 2021 Jul; 29(7):2064-2069. PubMed ID: 32382804
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of clinical results of surgical treatment for unstable distal clavicle fractures by transacromial pins with and without tension band wire.
    Tsuei YC; Au MK; Chu W
    J Chin Med Assoc; 2010 Dec; 73(12):638-43. PubMed ID: 21145512
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Plate versus intramedullary fixation of two-part and multifragmentary displaced midshaft clavicle fractures - a long-term analysis.
    Chan G; Korac Z; Miletic M; Vidovic D; Phadnis J; Bakota B
    Injury; 2017 Nov; 48 Suppl 5():S21-S26. PubMed ID: 29122117
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Displaced medial end clavicular fractures treated with an inverted distal clavicle plate contoured through 90 degrees.
    Titchener A; See A; Van Rensburg L; Tytherleigh-Strong G
    J Shoulder Elbow Surg; 2019 Apr; 28(4):e97-e103. PubMed ID: 30454930
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Supplementary Technique for Unstable Clavicle Shaft Fractures: Interfragmentary Wiring and Temporary Axial K-Wire Pinning.
    Dan J; Kim BK; Lee HJ; Kim TH; Kim YG
    Clin Orthop Surg; 2018 Jun; 10(2):142-148. PubMed ID: 29854336
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Innovative use of single-incision internal fixation of distal clavicle fractures augmented with coracoclavicular stabilisation.
    Nandra R; Kowalski T; Kalogrianitis S
    Eur J Orthop Surg Traumatol; 2017 Dec; 27(8):1057-1062. PubMed ID: 28540473
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Displaced medial clavicle fractures: operative treatment with locking compression plate fixation.
    Frima H; Houwert RM; Sommer C
    Eur J Trauma Emerg Surg; 2020 Feb; 46(1):207-213. PubMed ID: 30310957
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Clavicle hook plate fixation for displaced lateral-third clavicle fractures (Neer type II): a functional outcome study.
    Good DW; Lui DF; Leonard M; Morris S; McElwain JP
    J Shoulder Elbow Surg; 2012 Aug; 21(8):1045-8. PubMed ID: 22014616
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Open reduction and endobutton fixation of displaced fractures of the lateral end of the clavicle in younger patients.
    Robinson CM; Akhtar MA; Jenkins PJ; Sharpe T; Ray A; Olabi B
    J Bone Joint Surg Br; 2010 Jun; 92(6):811-6. PubMed ID: 20513878
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Outcome of distal end clavicle fractures treated with locking plates.
    Vaishya R; Vijay V; Khanna V
    Chin J Traumatol; 2017 Feb; 20(1):45-48. PubMed ID: 28233729
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Interfragmentary suture fixation for displaced acute type II distal clavicle fractures.
    Duralde XA; Pennington SD; Murray DH
    J Orthop Trauma; 2014 Nov; 28(11):653-8. PubMed ID: 24714404
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Outcome of arthroscopic treatment for displaced lateral clavicle fractures using a double button device.
    Loriaut P; Moreau PE; Dallaudière B; Pélissier A; Vu HD; Massin P; Boyer P
    Knee Surg Sports Traumatol Arthrosc; 2015 May; 23(5):1429-1433. PubMed ID: 24213685
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Midshaft Fractures of the Clavicle: A Meta-analysis Comparing Surgical Fixation Using Anteroinferior Plating Versus Superior Plating.
    Nourian A; Dhaliwal S; Vangala S; Vezeridis PS
    J Orthop Trauma; 2017 Sep; 31(9):461-467. PubMed ID: 28708779
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.