These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
118 related articles for article (PubMed ID: 22392652)
1. Is the CPAP estimate of the apnea-hypopnea index on therapy clinically useful? Mador MJ Sleep Breath; 2013 Mar; 17(1):15-6. PubMed ID: 22392652 [No Abstract] [Full Text] [Related]
2. The accuracy of autotitrating CPAP-determined residual apnea-hypopnea index. Cilli A; Uzun R; Bilge U Sleep Breath; 2013 Mar; 17(1):189-93. PubMed ID: 22371206 [TBL] [Abstract][Full Text] [Related]
4. A continuous positive airway pressure trial as a novel approach to the diagnosis of the obstructive sleep apnea syndrome. Senn O; Brack T; Russi EW; Bloch KE Chest; 2006 Jan; 129(1):67-75. PubMed ID: 16424414 [TBL] [Abstract][Full Text] [Related]
5. Analysis of cardiopulmonary coupling to assess adaptive servo-ventilation success in complex sleep apnea management. Ramar K; Desrues B; Ramar P; Morgenthaler TI Sleep Breath; 2013 May; 17(2):861-6. PubMed ID: 23117897 [TBL] [Abstract][Full Text] [Related]
6. Effect of automatic versus fixed continuous positive airway pressure for the treatment of obstructive sleep apnea: an up-to-date meta-analysis. Xu T; Li T; Wei D; Feng Y; Xian L; Wu H; Xu J Sleep Breath; 2012 Dec; 16(4):1017-26. PubMed ID: 22139138 [TBL] [Abstract][Full Text] [Related]
7. The effect of continuous positive airway pressure on cardiopulmonary coupling. Cho JH; Kim HJ Sleep Breath; 2017 May; 21(2):341-345. PubMed ID: 27722946 [TBL] [Abstract][Full Text] [Related]
8. Comparison between the apnea-hypopnea indices determined by the REMstar Auto M series and those determined by standard in-laboratory polysomnography in patients with obstructive sleep apnea. Ikeda Y; Kasai T; Kawana F; Kasagi S; Takaya H; Ishiwata S; Narui K Intern Med; 2012; 51(20):2877-85. PubMed ID: 23064561 [TBL] [Abstract][Full Text] [Related]
9. Clinical Use of Loop Gain Measures to Determine Continuous Positive Airway Pressure Efficacy in Patients with Complex Sleep Apnea. A Pilot Study. Stanchina M; Robinson K; Corrao W; Donat W; Sands S; Malhotra A Ann Am Thorac Soc; 2015 Sep; 12(9):1351-7. PubMed ID: 26214564 [TBL] [Abstract][Full Text] [Related]
10. Medical devices for the diagnosis and treatment of obstructive sleep apnea. Cistulli PA; Grunstein RR Expert Rev Med Devices; 2005 Nov; 2(6):749-63. PubMed ID: 16293102 [TBL] [Abstract][Full Text] [Related]
11. Engineering sleep disorders: from classical CPAP devices toward new intelligent adaptive ventilatory therapy. Jane R IEEE Pulse; 2014; 5(5):29-32. PubMed ID: 25437472 [TBL] [Abstract][Full Text] [Related]
12. [Unattended automated titration to determine therapeutic continuous positive airway pressure in patients with obstructive sleep apnea]. Sato K; Hashimoto T Nihon Jibiinkoka Gakkai Kaiho; 2004 May; 107(5):494-9. PubMed ID: 15198010 [TBL] [Abstract][Full Text] [Related]
13. Low frequency filtering of nasal pressure channel causes loss of flow limitation. Walter RN; Vaughn BV Neurodiagn J; 2013 Mar; 53(1):58-62. PubMed ID: 23682540 [TBL] [Abstract][Full Text] [Related]
14. Evaluating the sleep quality of obstructive sleep apnea patients after continuous positive airway pressure treatment. Hsu CC; Wu JH; Chiu HC; Lin CM Comput Biol Med; 2013 Aug; 43(7):870-8. PubMed ID: 23746729 [TBL] [Abstract][Full Text] [Related]
15. Usefulness of cardiac parasympathetic index in CPAP-treated patients with obstructive sleep apnea: A preliminary study. Salsone M; Marelli S; Vescio B; Quattrone A; Gambardella A; Castelnuovo A; Quattrone A; Ferini Strambi L J Sleep Res; 2020 Apr; 29(2):e12893. PubMed ID: 31368146 [TBL] [Abstract][Full Text] [Related]
16. Central sleep apnea on commencement of continuous positive airway pressure in patients with a primary diagnosis of obstructive sleep apnea-hypopnea. Lehman S; Antic NA; Thompson C; Catcheside PG; Mercer J; McEvoy RD J Clin Sleep Med; 2007 Aug; 3(5):462-6. PubMed ID: 17803008 [TBL] [Abstract][Full Text] [Related]
17. Accuracy of residual apnea-hypopnea index obtained using the continuous positive airway pressure device: application of new version 2.0 scoring rules for respiratory events during sleep. Kim DE; Hwangbo Y; Bae JH; Yang KI Sleep Breath; 2015 Dec; 19(4):1335-41. PubMed ID: 26407962 [TBL] [Abstract][Full Text] [Related]
18. Accuracy of autotitrating CPAP to estimate the residual Apnea-Hypopnea Index in patients with obstructive sleep apnea on treatment with autotitrating CPAP. Desai H; Patel A; Patel P; Grant BJ; Mador MJ Sleep Breath; 2009 Nov; 13(4):383-90. PubMed ID: 19408029 [TBL] [Abstract][Full Text] [Related]
19. [The clinical recognition and simple diagnostic procedures for obstructive sleep apnea and hypopnea syndrome]. Liu HG; Xu YJ Zhonghua Jie He He Hu Xi Za Zhi; 2007 Dec; 30(12):886-8. PubMed ID: 18336760 [No Abstract] [Full Text] [Related]
20. [Continuous positive airway pressure treatment for obstructive sleep apnea hypopnea syndrome]. Luo YM Zhonghua Jie He He Hu Xi Za Zhi; 2007 Dec; 30(12):889-91. PubMed ID: 18336761 [No Abstract] [Full Text] [Related] [Next] [New Search]